Flow Cytometers / Flow Cytometry Systems

Flow cytometers are specialized instruments that analyze populations of cells and particles using laser-based fluorescence detection. Particles are suspended in a stream of fluid and flow through a detector in a single file. Individual particles are then analyzed using fluorescent markers, such as conjugated specific antibodies. A cell sorter is a type of cytometer that also isolates and collects desired cell populations for further analysis or for cell culture. Image cytometers, meanwhile use microscopy and fluorescence imaging capabilities for cell analysis. Flow cytometry is widely used in basic and clinical research for techniques such as cell counting, cell characterization, cell-based assays, protein and biomarker detection, microbial analysis, and more.

Browse our catalog of flow cytometers from leading manufacturers and evaluate models by different attributes, such as the number of detection parameters, number of lasers, accommodated laser wavelengths, sample input formats, throughput, and more. Instruments may also come with unique software, which should be user-friendly for flow cytometry novices, and advanced for experienced users to perform sophisticated experimental setups and analyses. Consider whether your laboratory needs a system that permits customization and provides imaging capability, and the degree of resolution your lab requires. Look for features such as automatic start-up, shutdown or cleaning, partially or fully automated processing, and quality customer support and service provided by the manufacturer.

Flow Cytometers / Flow Cytometry Systems

Your search returned 28 Flow Cytometers / Flow Cytometry Systems across 8 suppliers.
Showing 28 of 28 products
  • <<
  • >>
Select up to 5 products from below to compare or request more information.

Sponsored Products

MACSQuant&#174; Analyzer 16 Flow Cytometer
  • Abs / Exc:
    405 nm (violet), 488 nm (blue), 640 nm (red)
  • Detection:
    FSC, SSC, 14 fluorescence channels
  • Throughput:
    Up to 15,000 events per second
Citations:
(56)
iQue&#174; 3 Advanced Flow Cytometry Platform
  • Abs / Exc:
    405 nm, 488 nm, 561 nm, 640 nm
  • Detection:
    Up to 15 detection channels
  • Throughput:
    35,000 events/second, < 5 minutes/96 wells, < 20 minutes/384 wells
Citations:
(21)
Cytek&#153; Aurora Flow Cytometry System
  • Abs / Exc:
    3-5 lasers - 405 nm: 100 mW, 488 nm: 50 mW, 640 nm: 80 mW, 355 nm: 20mW, 561 nm: 50mW
  • Detection:
    FSC, SSC, up to 64 fluorescent detectors
  • Throughput:
    Inquire
Citations:
(3)
BD FACSLyric&#153; Flow Cytometer Integrated with the BD FACSDuet&#153; Sample Preparation System
  • Abs / Exc:
    Solid state lasers: Blue laser: 488 nm, Red laser: 640 nm, Violet laser: 405 nm
  • Detection:
    FSC, SSC, up to 12 fluorescence detection channels
  • Sample Type:
    96-well, 384-well, 40-tube rack
  • Throughput:
    35,000 events per second
Read More
Citations:
(1)
BD FACSymphony&#153; A5 SE Cell Analyzer
  • Abs / Exc:
    355 nm - 60 mW 405 nm - 200 mW 488 nm - 150 mW 561 nm - 150 mW 637 nm - 140 mW
  • Detection:
    50 detection parameters (including FSC and SSC) featuring cascadegon arrays with 48 fluorescent ...
  • Sample Type:
    5.0-mL polystyrene and polypropylene tubes, optional high throughput sampler to acquire samples from...
  • Throughput:
    Inquire
Read More
Cytek&#153; Northern Lights Flow Cytometery System
  • Abs / Exc:
    1-3 lasers - 405 nm: 100 mW, 488 nm: 50 mW, 640 nm: 80 mW
  • Detection:
    FSC, SSC, up to 38 fluorescent detectors
  • Throughput:
    Inquire
Citations:
(80)
BD FACSymphony&#153; A1 Cell Analyzer
  • Abs / Exc:
    405 nm, 488 nm, 561 nm, 637 nm
  • Detection:
    FSC, SSC, Small Particle SSC, and 16 fluorescence detection channels.
  • Sample Type:
    12 x 75-mm tubes; Optional High-Throughput Sampler for 96- or 384-well microtiter plate.
  • Throughput:
    Inquire
Read More
Citations:
(12)
MACSQuant&#174; Tyto&#174; Cell Sorter
  • Abs / Exc:
    405 nm, 488 nm, 638 nm
  • Detection:
    Backscatter detector, Sidescatter detector and eight fluorescence detectors
  • Sample Type:
    Cartridge details: 100 µL–10 mL max loading volume; 5×107 cells/mL max loading cell number
  • Throughput:
    up to 110,000 cells/s
Read More
Citations:
(53)
BD FACSymphony&#153; S6 Cell Sorter
  • Abs / Exc:
    355 nm, 375 nm, 405 nm, 420 nm, 445 nm, 458 nm, 460 nm, 473 nm, 488 nm, 505 nm, 514 nm, 532 nm, 552 ...
  • Detection:
    50 detection parameters (including FSC and SSC), featuring decagon arrays for up to 10 parameters on...
  • Sample Type:
    5.0-mL polystyrene and polypropylene tubes, optional high throughput sampler to acquire samples from...
  • Throughput:
    Inquire
Read More
Citations:
(35)
BD FACSMelody&#153; Cell Sorter
  • Abs / Exc:
    488 nm (Blue), 640 nm (Red), 405 nm (Violet), 561 nm (Yellow/Green)
  • Detection:
    FSC, SSC, Up to 9 fluorescence detection channels with optional changeable filters
  • Sample Type:
    5.0-mL polystyrene and polypropylene tubes
  • Throughput:
    10,000 cells/second; 40,000 events per second; 2-way sorting
Read More
Citations:
(203)
MACSQuant<sup>&#174;</sup> VYB Flow Cytometer
  • Abs / Exc:
    405 nm (violet)
    488 nm (blue)
    561 nm (yellow)
  • Detection:
    FSC, SSC, 8 fluorescence channels
  • Sample Type:
    1.5/2.0/5.0/15/50 mL tubes or 24/48/96-well plates
  • Throughput:
    Up to 15,000 events per second
Read More
Citations:
(447)
Figures:
(1)
ZE5 Cell Analyzer
  • Abs / Exc:
    Up to five spatially separated lasers. Standard options include:
    355 nm, 50 mW
    488 nm, 100 mW
    640 nm, ...
  • Detection:
    Up to five lasers and 30 detectors including seven colors
  • Sample Type:
    Up to 40 5 mL (12 x 75 mm) tube rack, up to 24 1.5- and 2-mL micro-centrifuge tube rack, 96- or 384-...
  • Throughput:
    Inquire
Read More
Citations:
(384)
Figures:
(6)
MACSQuant<sup>&#174;</sup> X Flow Cytometer
  • Abs / Exc:
    405 nm (violet)
    488 nm (blue)
    640 nm (red)
  • Detection:
    FSC, SSC, 8 fluorescence channels
  • Sample Type:
    1.5/2.0/5.0/15/50 mL tubes or 24/48/96/384-well plates
  • Throughput:
    Up to 15,000 events per second
Read More
Citations:
(57)
BD FACSLyric&#153; Flow Cytometry System
  • Abs / Exc:
    Solid state lasers: Blue laser: 488 nm, 20 mW
    Red laser: 640 nm, 40 mW
    Violet laser: 405 nm, 40 mW...
  • Detection:
    FSC, SSC, up to 12 fluorescence detection channels; FSC and SSC resolution enables separation of 0.2...
  • Sample Type:
    ≤ 50 minutes for a 40-tube rack with a standard BD Tritest assay stopping rule on samples with ...
  • Throughput:
    35,000 events per second
Read More
Citations:
(181)
Figures:
(4)
MACSQuant<sup>&#174;</sup> Analyzer 10 Flow Cytometer
  • Abs / Exc:
    405 nm (violet)
    488 nm (blue)
    640 nm (red)
  • Detection:
    FSC, SSC, 8 fluorescence channels
  • Sample Type:
    1.5/2.0/5.0/15/50 mL tubes or 24/48/96-well plates
  • Throughput:
    Up to 15,000 events per second
Read More
Citations:
(440)
Figures:
(2)
NovoCyte Benchtop Flow Cytometer

NovoCyte Benchtop Flow Cytometer

Agilent Technologies

  • Abs / Exc:
    488 nm, 640 nm, 405 nm
  • Detection:
    Up to 17 parameters
  • Sample Type:
    12 × 75 mm tubes, 1.5 & 2 mL tubes, 24-well and 96-well microtiter plates
Citations:
(1)
BD Accuri&#153; C6 Plus Flow Cytometer
  • Abs / Exc:
    488 nm (Blue), 640 nm (Red)
  • Detection:
    The system is equipped with a blue laser and a red laser, and capable of 6 detection parameters; (...
  • Sample Type:
    Standard 96-well plates (flat, round and v-bottom) Deep-well 96-well plates 48-well plates. Plates ...
  • Throughput:
    Inquire
Read More
Citations:
(419)
Figures:
(2)
NovoCyte Quanteon Flow Cytometer

NovoCyte Quanteon Flow Cytometer

Agilent Technologies

  • Abs / Exc:
    405 nm, 488 nm, 561 nm, 637 nm
  • Detection:
    25 independent photomultipliers
  • Sample Type:
    12 × 75 mm tubes, 1.5 and 2 mL tubes, 24-well, 48-well, 96-well and 384-well microtiter plates
Citations:
(120)
CyTOF&reg; XT Next Generation Mass Cytometer
  • Abs / Exc:
    Inquire
  • Detection:
    135 Channels; 75–209 amu (Mass range)
  • Sample Type:
    Single-cell suspension; Sample format: 12 x 5 mL tube positions 1 x 15 mL tube positions
  • Throughput:
    Flow rate: 30 µL/min
Invitrogen&#8482; Attune&#8482; CytPix&#8482; Flow Cytometer
  • Abs / Exc:
    405 nm, 488 nm, 561 nm, 637 nm
  • Detection:
    2 scatter channels, up to 14 fluorescence channels; Brightfield imaging capability
  • Sample Type:
    17 x 100 mm to 8.5 x 45 mm tubes
  • Throughput:
    Inquire
Citations:
(7)
Invitrogen&#8482; Bigfoot&#8482; Cell Sorter

Invitrogen™ Bigfoot™ Cell Sorter

Thermo Fisher Scientific

  • Abs / Exc:
    349 nm, 405 nm, 445 nm, 488 nm, 532 nm, 561 nm, 594 nm, 640 nm, 785 nm
  • Detection:
    Up to 60 parameters, including FSC and SSC
  • Sample Type:
    Sample Input: 1.5 mL, 5 mL, and 15 mL
  • Throughput:
    > 100,000 eps acquisition and > 70,000 eps sorting with all 60 parameters
Read More
Citations:
(17)
BD FACSCelesta&#153; Flow Cytometer
  • Abs / Exc:
    488 nm (Blue), 640 nm (Red), 405 nm (Violet), 561 nm (Yellow/Green), 355 nm (UV)
  • Detection:
    FSC, SSC, up to 12 fluorescence colors
  • Sample Type:
    5 mL (12 x 75 mm) tubes, 96- or 384-well high-throughput sampler option
  • Throughput:
    15 min per microtiter plate in high-throughput mode using a 2-second acquisition; 44 minutes in ...
Read More
Citations:
(376)
BD LSRFortessa&#153; X-20 Cell Analyzer
  • Abs / Exc:
    488 nm (Blue), 640 nm (Red), 405 nm (Violet), 561 nm (Yellow/Green), 355 nm (UV)
  • Detection:
    FSC, SSC, up to 18 fluorescence colors
  • Sample Type:
    5 mL (12 x 75 mm) tubes, 96- or 384-well high-throughput sampler option
  • Throughput:
    Inquire
Read More
Citations:
(482)
Figures:
(1)
Invitrogen&#153; Attune&#153; NxT Flow Cytometer
  • Abs / Exc:
    Blue: 488 nm (50 mW), Violet: 405 nm (50 mW), Red:637 nm (100 mW) Yellow: 561 nm (50 mW)
  • Detection:
    FSC, SSC, 14 fluorescent colors with PMTs, User changeable
  • Sample Type:
    17 x 100 mm to 8.5 x 45 mm tubes
  • Throughput:
    35,000 events per second
Read More
Citations:
(>1k)
Figures:
(4)
BD FACSymphony&#153; A5 Cell Analyzer
  • Abs / Exc:
    355 nm, 375 nm, 405 nm, 420 nm, 445 nm, 458 nm, 460 nm, 473 nm, 488 nm, 505 nm, 514 nm, 532 nm, 552 ...
  • Detection:
    50 detection parameters (including FSC and SSC) featuring decagon arrays for up to 10 parameters on...
  • Sample Type:
    5.0-mL polystyrene and polypropylene tubes, optional high throughput sampler to acquire samples ...
  • Throughput:
    Inquire
Read More
Citations:
(71)
BD FACSymphony&#153; A3 Cell Analyzer
  • Abs / Exc:
    355 nm, 375 nm, 405 nm, 420 nm, 445 nm, 458 nm, 460 nm, 473 nm, 488 nm, 505 nm, 514 nm, 532 nm, 552 ...
  • Detection:
    30 detection parameters (including FSC and SSC) featuring decagon arrays for up to 10 parameters on ...
  • Sample Type:
    5.0-mL polystyrene and polypropylene tubes, optional high throughput sampler to acquire
  • Throughput:
    Inquire
Read More
Citations:
(20)
BD LSRFortessa&#153; Cell Analyzer
  • Abs / Exc:
    488 nm (Blue), 640 nm (Red), 405 nm (Violet), 355 nm (UV)
  • Detection:
    FSC, SSC, up to 18 fluorescence colors
  • Sample Type:
    5 mL (12 x 75 mm) tubes, 96- or 384-well high-throughput sampler option
  • Throughput:
    Inquire
Read More
Citations:
(>1k)
Figures:
(10)
Guava&#174; easyCyte&#0153; Flow Cytometers
  • Abs / Exc:
    Violet (405 nm), Blue (488 nm), Red (642 nm)
  • Detection:
    FSC, SSC, 12 fluorescent colors depending on model
  • Sample Type:
    96 Well Plates, 1.2 or 1.5 mL Tubes depending on model
  • Throughput:
    1,000 – 10,000 cells/test
Read More
Citations:
(156)
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
Miltenyi Biotec
130-096-116
2
1 Figure from 416 Publications
Bio-Rad
12004276 / 12004277 / 12004278 / 12004279 / 12014135 / 12014136 / 12014138 / 12014139 / 12014141
6
6 Figures from 339 Publications
BD Biosciences
BD FACSLyric
1
4 Figures from 163 Publications
Miltenyi Biotec
130-196-434
7
2 Figures from 397 Publications
BD Biosciences
BD Accuri C6 Plus
5
2 Figures from 379 Publications
Thermo Fisher Scientific
Attune NxT Flow Cytometer
3
4 Figures from 1653 Publications
BD Biosciences
BD LSRFortessa X-20
4
1 Figure from 472 Publications
BD Biosciences
BD LSRFortessa
4
10 Figures from 4232 Publications
Showing 8 of 8 products
  • <<
  • >>