Flow Cytometers / Flow Cytometry Systems Flow cytometers are specialized instruments that analyze populations of cells and particles using laser-based fluorescence detection. Particles are suspended in a stream of fluid and flow through a detector in a single file. Individual particles are then analyzed using fluorescent markers, such as conjugated specific antibodies. A cell sorter is a type of cytometer that also isolates and collects desired cell populations for further analysis or for cell culture. Image cytometers, meanwhile use microscopy and fluorescence imaging capabilities for cell analysis. Flow cytometry is widely used in basic and clinical research for techniques such as cell counting, cell characterization, cell-based assays, protein and biomarker detection, microbial analysis, and more.

Browse our catalog of flow cytometers from leading manufacturers and evaluate models by different attributes, such as the number of detection parameters, number of lasers, accommodated laser wavelengths, sample input formats, throughput, and more. Instruments may also come with unique software, which should be user-friendly for flow cytometry novices, and advanced for experienced users to perform sophisticated experimental setups and analyses. Consider whether your laboratory needs a system that permits customization and provides imaging capability, and the degree of resolution your lab requires. Look for features such as automatic start-up, shutdown or cleaning, partially or fully automated processing, and quality customer support and service provided by the manufacturer.

Flow Cytometers / Flow Cytometry Systems

Your search returned 55 Flow Cytometers / Flow Cytometry Systems across 13 suppliers.
Showing 55 of 55 products
  • <<
  • >>
Select up to 5 products from below to compare or request more information.

Sponsored Products

Cytek Aurora<sup>&#8482;</sup> CS System

Cytek Aurora CS System

Cytek Biosciences

  • Excitation:
    355 nm (20 mW), 405 nm (100 mW), 488 nm (50 mW), ...
  • Parameters:
    64 fluorescence channels
  • Capacity:
    Tubes (5 mL, 15 mL)
  • Data Throughput:
    25,000 events/sec
Citations:
(105)
Figures:
(2)
Cytek Aurora<sup>&#8482;</sup> Evo Flow Cytometer
  • Lasers:
    2 to 5 lasers
  • Excitation:
    355 nm (20 mW), 405 nm (100 mW), 488 nm (50 mW), ...
  • Parameters:
    Up to 64 high sensitivity fluorescence channels with 3 ...
  • Capacity:
    Tubes (5 mL), microplates using autosampler (96-well, 384-...
Read More
Cytek<sup>&#174;</sup> Muse<sup>&#174;</sup> Micro Cell Analyzer
  • Lasers:
    1 laser
  • Excitation:
    488 nm
  • Parameters:
    5 parameters
  • Capacity:
    Tubes
  • Data Throughput:
    Inquire
Citations:
(1)
Invitrogen&#8482; Attune&#8482; CytPix&#8482; Flow Cytometer
  • Lasers:
    2 to 4 lasers
  • Excitation:
    488 nm (50 mW), 405 nm (50 mW), 637 nm (100 mW), ...
  • Parameters:
    14 fluorescence channels
  • Capacity:
    Tubes (1 mL, 5 mL, 15 mL)
  • Data Throughput:
    35,000 events/sec
Citations:
(7)
NovoCyte Advanteon Flow Cytometer Systems
  • Lasers:
    1 to 3 lasers
  • Excitation:
    405 nm (50 mW), 488 nm (60 mW), 561 nm (50 mW), ...
  • Parameters:
    23 parameters / 21 fluorescence channels
  • Capacity:
    Tubes, Microplates using autosampler (48-well, 96-well, 384-...
  • Data Throughput:
    100,000 events/sec
Read More
Citations:
(109)
NovoCyte Benchtop Flow Cytometer

NovoCyte Benchtop Flow Cytometer

Agilent Technologies

  • Lasers:
    1 to 3 lasers
  • Excitation:
    405 nm, 488 nm, 640 nm
  • Parameters:
    17 parameters / 15 fluorescence channels
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL), Microplates (96-well)
  • Data Throughput:
    35,000 events/sec
Citations:
(3)
NovoCyte Opteon Spectral Flow Cytometer Systems
  • Lasers:
    3 to 5 lasers
  • Excitation:
    349 nm (20 mW), 405 nm (130 mW), 488 nm (100 mW), ...
  • Parameters:
    73 parameters
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL), Microplates using autosampler (...
  • Data Throughput:
    100,000 events/sec
Read More
Citations:
(1)
NovoCyte Penteon Flow Cytometer Systems
  • Lasers:
    Up to 5 lasers
  • Excitation:
    349 nm (20 mW), 405 nm (100 mW), 488 nm (100 mW), ...
  • Parameters:
    30 fluorescence channels
  • Capacity:
    Tubes, Microplates using autosampler (48-well, 96-well, 384-...
  • Data Throughput:
    100,000 events/sec
Read More
Citations:
(47)
NovoCyte Quanteon Flow Cytometer

NovoCyte Quanteon Flow Cytometer

Agilent Technologies

  • Lasers:
    4 lasers
  • Excitation:
    405 nm (100 mW), 488 nm (100 mW), 561 nm (100 mW),...
  • Parameters:
    25 parameters
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL), Microplates (48-well, 96-well, ...
  • Data Throughput:
    100,000 events/sec
Read More
Citations:
(437)
BD Accuri&#153; C6 Plus Flow Cytometer
  • Lasers:
    2 lasers
  • Excitation:
    488 nm, 640 nm
  • Parameters:
    6 parameters / 4 fluorescence channels
  • Capacity:
    Tubes (5 mL), Microplates using autosampler (48-well, 96-...
  • Data Throughput:
    10,000 events/sec
Citations:
(722)
Figures:
(3)
BD FACSDiscover&#8482; S8 Cell Sorter
  • Lasers:
    5 lasers
  • Excitation:
    349 nm (30 mW), 405 nm (50 mW), 488 nm (100 mW), ...
  • Parameters:
    78 fluorescence channels
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL)
  • Data Throughput:
    10,000 events/sec (sorting)
Citations:
(55)
Figures:
(4)
BD FACSDiscover&#8482; A8 Cell Analyzer
  • Parameters:
    78 fluorescence channels, 8 scatter and imaging channels
  • Capacity:
    Tubes (1.5 mL, 5 mL), Autosampler
  • Data Throughput:
    35,000 events/sec; 12,500 events/sec (imaging)
Citations:
(2)
BD FACSLyric&#153; Flow Cytometer Integrated with the BD FACSDuet&#153; Sample Preparation System
  • Lasers:
    3 lasers
  • Excitation:
    488 nm (20 mW), 640 nm (40 mW), 405 nm (40 mW)
  • Parameters:
    12 fluorescence channels
  • Capacity:
    Tubes, Microplates (96-well, 384-well)
  • Data Throughput:
    35,000 events/sec
Citations:
(3)
BD FACSLyric&#153; Flow Cytometry System
  • Lasers:
    2 to 3 lasers
  • Parameters:
    14 parameters / 12 fluorescence channels
  • Capacity:
    Tubes (5 mL, 2 mL, 15 mL, 50 mL), Microplates (96-well, 384-...
  • Data Throughput:
    35,000 events/sec
Citations:
(452)
Figures:
(4)
BD FACSMelody&#153; Cell Sorter
  • Lasers:
    3 lasers
  • Excitation:
    488 nm (20 mW), 640 nm (40 mW), 405 nm (36 mW), ...
  • Parameters:
    9 fluorescence channels
  • Capacity:
    Tubes (5 mL)
  • Data Throughput:
    40,000 events/sec; 10,000 cells/sec (sorting)
Citations:
(388)
BD FACSymphony&#153; A1 Cell Analyzer
  • Excitation:
    405 nm (100 mW), 488 nm (100 mW), 561 nm (100 mW),...
  • Parameters:
    16 fluorescence channels
  • Capacity:
    Tubes (5 mL), Microplates using autosampler (96-well, 384-...
  • Data Throughput:
    10,000 events/sec; 25,000 events/sec (max)
Read More
Citations:
(118)
BD FACSymphony&#153; A5 SE Cell Analyzer
  • Excitation:
    355 nm (60 mW), 405 nm (200 mW), 488 nm (150 mW), ...
  • Parameters:
    50 parameters
  • Capacity:
    Tubes (5 mL), Microplates using autosampler (96-well, 384-...
  • Data Throughput:
    40,000 events/sec
Citations:
(11)
BD FACSymphony&#153; S6 Cell Sorter
  • Lasers:
    Up to 9 lasers
  • Excitation:
    355 nm, 375 nm, 405 nm, 420 nm, 445 nm, 458 nm, ...
  • Parameters:
    50 parameters
  • Capacity:
    Tubes (1.5 mL, 2 mL, 5 mL, 15 mL), Microplates using ...
  • Data Throughput:
    25,000 to 70,000 events/sec
Read More
Citations:
(122)
Figures:
(2)
BD FACSymphony&#153; A3 Cell Analyzer
  • Lasers:
    Up to 5 lasers
  • Excitation:
    355 nm, 375 nm, 405 nm, 420 nm, 445 nm, 458 nm, ...
  • Parameters:
    30 parameters / 28 fluorescence channels
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL), Microplates using autosampler (...
  • Data Throughput:
    40,000 events/sec
Read More
Citations:
(58)
BD FACSymphony&#153; A5 Cell Analyzer
  • Lasers:
    Up to 9 lasers
  • Excitation:
    355 nm, 375 nm, 405 nm, 420 nm, 445 nm, 458 nm, ...
  • Parameters:
    50 parameters
  • Capacity:
    Tubes (5 mL), Microplates using autosampler (96-well, 384-...
  • Data Throughput:
    40,000 events/sec
Read More
Citations:
(111)
AQUIOS CL Flow Cytometers

AQUIOS CL Flow Cytometers

Beckman Coulter Life Sciences

  • Lasers:
    1 laser
  • Excitation:
    488 nm
  • Parameters:
    4 fluorescence channels
  • Capacity:
    Tubes (5 mL), Microplates (96-well)
  • Data Throughput:
    Inquire
Citations:
(18)
CytoFLEX Flow Cytometer

CytoFLEX Flow Cytometer

Beckman Coulter Life Sciences

  • Lasers:
    1 to 3 lasers
  • Excitation:
    488 nm (50 mW), 638 nm (50 mW), 405 nm (80 mW), ...
  • Parameters:
    13 fluorescence channels
  • Capacity:
    Microplates (96-well)
  • Data Throughput:
    30,000 events/sec
Citations:
(>1k)
Figures:
(12)
CytoFLEX LX Flow Cytometer

CytoFLEX LX Flow Cytometer

Beckman Coulter Life Sciences

  • Lasers:
    4 to 6 lasers
  • Excitation:
    355 nm (20 mW), 375 nm (60 mW), 405 nm (80 mW), ...
  • Parameters:
    21 fluorescence channels
  • Capacity:
    Microplates (96-well)
  • Data Throughput:
    30,000 events/sec
Citations:
(388)
Figures:
(5)
CytoFLEX S Flow Cytometer

CytoFLEX S Flow Cytometer

Beckman Coulter Life Sciences

  • Lasers:
    2 to 4 lasers
  • Excitation:
    405 nm (80 mW), 488 nm (50 mW), 561 nm (30 mW), ...
  • Parameters:
    13 fluorescence channels
  • Capacity:
    Microplates (96-well)
  • Data Throughput:
    30,000 events/sec
Citations:
(780)
Figures:
(2)
CytoFLEX SRT Benchtop Cell Sorters

CytoFLEX SRT Benchtop Cell Sorters

Beckman Coulter Life Sciences

  • Lasers:
    4 lasers
  • Excitation:
    405 nm (90 mW), 488 nm (50 mW), 561 nm (30 mW), ...
  • Parameters:
    15 fluorescence channels
  • Capacity:
    Tubes (5 mL, 15 mL), Microplates (48-well, 96-well, 384-well...
  • Data Throughput:
    40,000 particles/sec; 30,000 particles/sec (sorting)
Read More
Citations:
(59)
CytoFLEX mosaic Spectral Detection Module

CytoFLEX mosaic Spectral Detection Module

Beckman Coulter Life Sciences

  • Lasers:
    2 to 6 lasers
  • Parameters:
    88 fluorescence channels
  • Capacity:
    Inquire
  • Data Throughput:
    Inquire
CytoFLEX nano Flow Cytometer

CytoFLEX nano Flow Cytometer

Beckman Coulter Life Sciences

  • Lasers:
    4 lasers
  • Excitation:
    405 nm (120 mW), 488 nm (50 mW), 561 nm (35 mW), ...
  • Parameters:
    12 parameters / 6 fluorescence channels
  • Capacity:
    Tubes (5 mL, 1.5 mL)
  • Data Throughput:
    5,000 events/sec; 16,000 events/sec (max)
Read More
Citations:
(9)
Navios EX Flow Cytometers

Navios EX Flow Cytometers

Beckman Coulter Life Sciences

  • Lasers:
    2 to 3 lasers
  • Excitation:
    405 nm (80 mW), 488 nm (55 mW), 638 nm (50 mW)
  • Parameters:
    12 parameters / 10 fluorescence channels
  • Capacity:
    Tubes (5 mL)
  • Data Throughput:
    25,000 events/sec
Citations:
(12)
ZE5 Cell Analyzer
  • Lasers:
    3 to 5 lasers
  • Parameters:
    30 parameters / 27 fluorescence channels
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL), Microplates (96-well, 384-well, ...
  • Data Throughput:
    100,000 events/sec
Citations:
(658)
Figures:
(6)
Cytek Aurora<sup>&#8482;</sup> Flow Cytometer

Cytek Aurora Flow Cytometer

Cytek Biosciences

  • Lasers:
    3 to 5 lasers
  • Excitation:
    405 nm (100 mW), 488 nm (50 mW), 640 nm (80 mW), ...
  • Parameters:
    67 parameters / 64 fluorescence channels
  • Capacity:
    Tubes (5 mL), Microplates (96-well)
  • Data Throughput:
    35,000 events/sec
Read More
Citations:
(251)
Cytek Northern Lights<sup>&#8482;</sup> Flow Cytometer
  • Lasers:
    1 to 3 lasers
  • Excitation:
    405 nm (100 mW), 488 nm (50 mW), 640 nm (80 mW)
  • Parameters:
    38 fluorescence channels
  • Capacity:
    Tubes (5 mL), Microplates (96-well)
  • Data Throughput:
    35,000 events/sec
Citations:
(410)
Figures:
(2)
Cytek<sup>&#174;</sup> Amnis<sup>&#174;</sup> ImageStream<sup>&#174;</sup><sup>X</sup> Mk II Imaging Flow Cytometer
  • Lasers:
    Up to 6 laser options
  • Excitation:
    375 nm (70 mW), 405 nm, (120 mW) 488 nm (200/400 ...
  • Parameters:
    12 fluorescence channels
  • Capacity:
    Microplates using autosampler (96-well)
  • Data Throughput:
    2,000 to 5,000 cells/sec
Read More
Citations:
(80)
Figures:
(1)
Cytek<sup>&#174;</sup> Guava<sup>&#174;</sup> easyCyte<sup>&#8482;</sup> Flow Cytometer
  • Lasers:
    1 to 3 lasers
  • Excitation:
    488 nm (50/150 mW), 532 nm (100 mW), 642 nm (100 ...
  • Parameters:
    14 parameters / 12 fluorescence channels
  • Capacity:
    Tubes (1.5 mL, 2 mL), Microplates (96-well)
  • Data Throughput:
    1,000 events/sec
Read More
Citations:
(175)
MACSQuant&#174; Analyzer 16 Flow Cytometer
  • Lasers:
    3 lasers
  • Excitation:
    405 nm (65 mW), 488 nm (50 mW), 640 nm (72 mW)
  • Parameters:
    16 parameters / 14 fluorescence channels
  • Capacity:
    Microplates (96-well)
  • Data Throughput:
    15,000 events/sec
Citations:
(143)
MACSQuant&#174; Tyto&#174; Cell Sorter
  • Lasers:
    3 lasers
  • Excitation:
    405 nm (100 mW), 488 nm (100 mW), 638 nm (100 mW)
  • Parameters:
    10 parameters / 8 fluorescence channels
  • Capacity:
    Cartridge
  • Data Throughput:
    110,000 cells/s
Citations:
(116)
MACSQuant<sup>&#174;</sup> Analyzer 10 Flow Cytometer
  • Lasers:
    3 lasers
  • Excitation:
    405 nm (40 mW), 488 nm (30 mW), 640 nm (20 mW)
  • Parameters:
    10 parameters / 8 fluorescence channels
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL, 15 mL, 50 mL), Microplates (48-...
  • Data Throughput:
    15,000 events/sec
Read More
Citations:
(721)
Figures:
(5)
MACSQuant<sup>&#174;</sup> VYB Flow Cytometer
  • Lasers:
    3 lasers
  • Excitation:
    405 nm (40 mW), 488 nm (50 mW), 561 nm (100 mW)
  • Parameters:
    10 parameters / 8 fluorescence channels
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL, 15 mL, 50 mL), Microplates (48-...
  • Data Throughput:
    15,000 events/sec
Read More
Citations:
(565)
Figures:
(1)
MACSQuant<sup>&#174;</sup> X Flow Cytometer
  • Lasers:
    3 lasers
  • Excitation:
    405 nm (40 mW), 488 nm (30 mW), 640 nm (20 mW)
  • Parameters:
    10 parameters / 8 fluorescence channels
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL, 15 mL, 50 mL), Microplates (48-...
  • Data Throughput:
    15,000 events/sec
Read More
Citations:
(99)
MACSQuant&#174; Tyto&#174; Lux Cell Sorter
  • Capacity:
    Inquire
  • Data Throughput:
    Inquire
iQue&#174; 3 High-Throughput Screening Cytometry Platform
  • Lasers:
    2 or 3 lasers
  • Excitation:
    405 nm, 488 nm, 561 nm, 640 nm
  • Parameters:
    15 parameters / 13 fluorescence channels
  • Capacity:
    Microplates (96-well, 384-well, 1536-well)
  • Data Throughput:
    35,000 events/sec
Citations:
(62)
iQue &#174; 5 High-Throughput Screening Cytometer
  • Lasers:
    405 nm, 488 nm, 561 nm, 637 nm
  • Capacity:
    Inquire
  • Data Throughput:
    Inquire
CyTOF&reg; XT Next Generation Mass Cytometer
  • Capacity:
    Inquire
  • Data Throughput:
    Inquire
Invitrogen&#153; Attune&#153; NxT Flow Cytometer
  • Lasers:
    1 to 4 lasers
  • Excitation:
    488 nm (50 mW), 405 nm (50 mW), 532 nm (100 mW), ...
  • Parameters:
    14 fluorescence channels
  • Capacity:
    Tubes (1 mL, 5 mL, 15 mL)
  • Data Throughput:
    35,000 events/sec
Citations:
(>1k)
Figures:
(4)
Invitrogen&#8482; Bigfoot&#8482; Cell Sorter

Invitrogen™ Bigfoot™ Cell Sorter

Thermo Fisher Scientific

  • Lasers:
    4 to 9 lasers
  • Excitation:
    349 nm (100 mW), 405 nm (100 mW), 445 nm (200 mW),...
  • Parameters:
    60 fluorescence channels
  • Capacity:
    Tubes (1.5 mL, 5 mL, 15 mL)
  • Data Throughput:
    100,000 events/sec; 70,000 events/sec (sorting)
Read More
Citations:
(54)
Invitrogen&#8482; Attune&#8482; Xenith&#8482; Flow Cytometer
  • Lasers:
    6 lasers
  • Excitation:
    349 nm (54 mW), 405 nm (100 mW), 488 nm (50 mW), ...
  • Parameters:
    57 parameters / 51 fluorescence channels
  • Capacity:
    Tubes (5 mL, 0.5 mL, 1.5 mL, 2 mL), Microplates with ...
  • Data Throughput:
    35,000 events/sec; 100,000 events/sec (max)
Read More
CytoStellar&#8482; Full Spectrum Flow Cytometer
  • Lasers:
    3 lasers
  • Excitation:
    405 nm, 488 nm, 638 nm
  • Parameters:
    38 fluorescence channels
  • Capacity:
    Tubes (5 mL), Microplates (96-well, 384-well)
  • Data Throughput:
    Inquire
Citations:
(1)
Inquire
FongCyte&#8482; Flow Cytometer
  • Lasers:
    1 to 3 lasers
  • Excitation:
    405 nm, 488 nm, 638 nm
  • Parameters:
    14 fluorescence channels
  • Capacity:
    Tubes (5 mL, 1.5 mL, 2 mL), Microplates (96-well)
  • Data Throughput:
    Inquire
Citations:
(15)
Inquire
CytoSense XR

CytoSense XR

CytoBuoy

  • Lasers:
    1 laser
  • Parameters:
    4 fluorescence channels
  • Capacity:
    Inquire
  • Data Throughput:
    10,000 particles/sec
Citations:
(1)
Inquire
FP7000 Spectral Cell Sorter

FP7000 Spectral Cell Sorter

Sony Corporation

  • Lasers:
    Up to 6 lasers
  • Excitation:
    320 nm (20 mW), 349 nm (60 mW), 405 nm (100 mW), ...
  • Parameters:
    182 fluorescence channels
  • Capacity:
    Tubes (1 mL, 1.5 mL, 5 mL, 15 mL)
  • Data Throughput:
    70,000 events/sec (max); 25,000 (sorting)
Read More
Citations:
(3)
Inquire
ID7000&#8482; Spectral Cell Analyzer
  • Lasers:
    3 to 7 lasers
  • Excitation:
    320 nm, 355 nm, 405 nm, 488 nm, 561 nm, 637 nm, ...
  • Parameters:
    186 fluorescence channels
  • Capacity:
    Tubes (5 mL), Microplates using autosampler (96-well, 384-...
  • Data Throughput:
    40,000 events/sec
Read More
Citations:
(319)
Figures:
(8)
Inquire
MA900 Multi-Application Cell Sorter
  • Lasers:
    2 lasers
  • Excitation:
    405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), ...
  • Parameters:
    14 parameters / 12 fluorescence channels
  • Capacity:
    Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
  • Data Throughput:
    70,000 events/sec (max)
Read More
Citations:
(748)
Figures:
(4)
Inquire
SA3800 Spectral Analyzer

SA3800 Spectral Analyzer

Sony Corporation

  • Lasers:
    1 to 4 lasers
  • Excitation:
    405 nm, 488 nm, 561 nm, 638 nm
  • Parameters:
    32 fluorescence channels
  • Capacity:
    Tubes (5 mL), Microplates (96-well, 384-well)
  • Data Throughput:
    20,000 events/sec (max)
Citations:
(311)
Figures:
(7)
Inquire
SP6800 Spectral Analyzer

SP6800 Spectral Analyzer

Sony Corporation

  • Lasers:
    2 or 3 lasers
  • Excitation:
    405nm (60mW), 488nm (40mW), 638nm (60mW)
  • Parameters:
    64 fluorescence channels
  • Capacity:
    Tubes (5 mL)
  • Data Throughput:
    10,000 events/sec; 20,000 events/sec (max)
Citations:
(186)
Figures:
(2)
Inquire
S1000EON Benchtop Flow Cytometer
  • Lasers:
    4 to 6 lasers
  • Excitation:
    372 nm (75 mW), 405 nm (100 mW), 488 nm (150 mW), ...
  • Parameters:
    30 parameters / 26 fluorescence channels
  • Capacity:
    Tubes
  • Data Throughput:
    20,000 events/sec
Citations:
(23)
Inquire
SE520EON Flow Cytometer
  • Lasers:
    2 lasers
  • Excitation:
    488 nm (150 mW), 640 nm (100 mW)
  • Parameters:
    6 fluorescence channels
  • Capacity:
    Tubes
  • Data Throughput:
    20,000 events/sec
Citations:
(2)
Inquire
Select up to 5 products from above to compare or request more information.

Tags:

Please Login or Register to Create Tags
  • <<
  • >>
BD Biosciences
BD Accuri C6 Plus
5
3 Figures from 722 Publications
BD Biosciences
FACSDiscover S8
8
4 Figures from 55 Publications
BD Biosciences
BD FACSLyric
1
4 Figures from 452 Publications
BD Biosciences
FACSymphony S6
8
2 Figures from 122 Publications
Beckman Coulter Life Sciences
CytoFLEX
3
12 Figures from 2594 Publications
Beckman Coulter Life Sciences
CytoFLEX LX
2
5 Figures from 388 Publications
Beckman Coulter Life Sciences
CytoFLEX S
8
2 Figures from 780 Publications
Bio-Rad
12004276 / 12004277 / 12004278 / 12004279 / 12014135 / 12014136 / 12014138 / 12014139 / 12014141
6
6 Figures from 658 Publications
Cytek Biosciences
Aurora CS
1
2 Figures from 105 Publications
Cytek Biosciences
Northern Lights
5
2 Figures from 410 Publications
Cytek Biosciences
ImageStream
3
1 Figure from 80 Publications
Miltenyi Biotec
130-196-434
7
5 Figures from 721 Publications
Miltenyi Biotec
130-096-116
2
1 Figure from 565 Publications
Thermo Fisher Scientific
A24858
3
4 Figures from 1704 Publications
Sony Corporation
ID7000
5
8 Figures from 319 Publications
Sony Corporation
MA900
8
4 Figures from 748 Publications
Sony Corporation
SA3800
4
7 Figures from 311 Publications
Sony Corporation
SP6800
2
2 Figures from 186 Publications
Showing 18 of 18 products
  • <<
  • >>