Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
SP6800 Spectral Analyzer
Supplier Images
Published Figures
SP6800 Spectral Analyzer
SP6800 Spectral Analyzer from Sony Corporation
Be the first to write a review!
Citations:
(204)
Figures:
(2)
Inquire
from
Sony Corporation for
SP6800 Spectral Analyzer
Description
SP6800 spectral analyzer / flow cytometer uses patented technologies and spectral technology to optimize sensitivity, and simplify multicolor panel design.
Product Specs
Citations
Reviews
Product Specs
Item
SP6800 Spectral Analyzer
Company
Sony Corporation
Price
Inquire
Catalog Number
SP6800
Detection
FSC, SSC, 32-channels (PMT arrays); cell position XY allows up to 64 channels
Lasers
2 or 3 lasers
Excitation
405nm (60mW), 488nm (40mW), 638nm (60mW)
Parameters
64 fluorescence channels
Capacity
Tubes (5 mL)
Data Throughput
10,000 events/sec; 20,000 events/sec (max)
Dimensions
(WxDxH) 60.0 x 63.5 x 71.3 cm
Add to Compare List
Citations (204)
(61)
Transition of signal requirement in hematopoietic stem cell development from hemogenic endothelial cells
Proceedings of the National Academy of Sciences
July 30, 2024
Saori Morino-Koga, Mariko Tsuruda, Xueyu Zhao, Shogo Oshiro, Tomomasa Yokomizo, Mariko Yamane, Shunsuke Tanigawa, Koichiro Miike, Shingo Usuki, Kei-ichiro Yasunaga,
et al.
CD8a-biotin), and further stained with streptavidin-AF700 (Fig. 2G). Stained cells were analyzed using an
SP6800
spectral cell analyzer (
SONY
). Transplantation and Blood Analysis. Cells were intravenously injected
(62)
Mechanisms of Resistance to Oncogenic KRAS Inhibition in Pancreatic Cancer
Cancer Discov
July 5, 2024
Julien Dilly, Megan T. Hoffman, Laleh Abbassi, Ziyue Li, Francesca Paradiso, Brendan D. Parent, Connor J. Hennessey, Alexander C. Jordan, Micaela Morgado, Shatavisha Dasgupta,
et al.
4°C, washed in PBS, and resuspended in 1% formalin for analysis on a spectral
flow cytometer
(
Sony
SP6800
).
Flow cytometry
antibodies were purchased from Biolegend [αCD45 (30-F11), αCD4 (RM4-5), αCD8 (53-6.7),
(63)
A liver immune rheostat regulates CD8 T cell immunity in chronic HBV infection
Nature
July 1, 2024
Bosch M, Kallin N, Donakonda S, Zhang JD, Wintersteller H, Hegenbarth S, Heim K, Ramirez C, Fürst A, Lattouf EI,
et al
.
(Genaxxon).
Flow cytometry
and
cell sorting
Multicolour
flow cytometry
data were acquired on a
Sony
SP6800
spectral analyser (Sony Biotechnology) or a CytoFLEX S (Beckman Coulter). Cells were sorted with a Sony
(64)
Synergistic Effects of Metal–Organic Nanoplatform and Guanine Quadruplex-Based CpG Oligodeoxynucleotides in Therapeutic Cancer Vaccines with Different Tumor Antigens
Vaccines (Basel)
June 11, 2024
Xia Li, Mitsuhiro Ebara, Naoto Shirahata, Tomohiko Yamazaki, Nobutaka Hanagata
PE-Cyanine7-anti-CD11c and APC-
anti-H-2Kb
of MHC class I bound to peptide SIINFEKL (
BioLegend
, San Diego, CA, USA).
SP6800
spectral cell analyzer (
Sony
, Tokyo, Japan) was used
for flow cytometry
and FlowJo software was used
(65)
PIK3CA inhibition in models of proliferative glomerulonephritis and lupus nephritis
J Clin Invest
June 6, 2024
Junna Yamaguchi, Pierre Isnard, Noémie Robil, Pierre de la Grange, Clément Hoguin, Alain Schmitt, Aurélie Hummel, Jérôme Megret, Nicolas Goudin, Marine Luka,
et al.
information, please refer to the Supplemental Methods.
Flow cytometry
was performed using the
Sony
SP6800
Spectral Cell Analyzer, and data were analyzed with FlowJo software (TreeStar). Preparation of single-cell
(66)
Small protein blockers of human IL-6 receptor alpha inhibit proliferation and migration of cancer cells
Cell communication and signaling : CCS
May 7, 2024
Groza Y, Lacina L, Kuchař M, Rašková Kafková L, Zachová K, Janoušková O, Osička R, Černý J, Petroková H, Mierzwicka JM,
et al
.
Streptavidin-PE conjugate antibody was incubated for 30 min at RT. Samples were measured by the
Sony
SP6800
Spectral Cell Analyzer (Sony Biotechnology, San Jose, CA, USA) and the data was processed using FlowJo
(67)
The Phytophthora parasitica effector AVH195 interacts with ATG8, attenuates host autophagy, and promotes biotrophic infection
BMC Biology
April 29, 2024
Serena Testi, Marie-Line Kuhn, Valérie Allasia, Pascaline Auroy, Fantao Kong, Gilles Peltier, Sophie Pagnotta, Julie Cazareth, Harald Keller, Franck Panabières
MegaPixel SIS Morada CCD camera (Olympus).
Flow cytometry
Analyses by
flow cytometry
were performed on a
SP6800
spectral cytometer (
SONY
Biotechnologies).
Chlamydomonas
cells were labeled with 7.5 μM CFSE (Life technologies;
(68)
Human cytomegalovirus exploits STING signaling and counteracts IFN/ISG induction to facilitate infection of dendritic cells
Nature communications
February 26, 2024
Costa B, Becker J, Krammer T, Mulenge F, Durán V, Pavlou A, Gern OL, Chu X, Li Y, Čičin-Šain L,
et al
.
according to the intracellular
labeling
protocol from BD Bioscience. Then the samples were acquired on a
SP6800
or
ID7000
(
Sony
) and the data were analyzed using FlowJo software (Tree Star). RFI was calculated as
(69)
MTHFD1 regulates the NADPH redox homeostasis in MYCN-amplified neuroblastoma
Cell Death & Disease
February 9, 2024
Jinqiu Guan, Mengzhen Li, Yi Wang, Yu Zhang, Yi Que, Suying Lu, Juan Wang, Jia Zhu, Junting Huang, Zijun Zhen,
et al.
buffer, sequentially stained with Annexin V-FITC and PI, and immediately analyzed by
flow cytometry
(
SP6800
,
Sony
, Japan). Detection of NADPH/NADP+ and GSH/GSSG ratios, and ROS content The intracellular NADPH/NADP+
(70)
AURKA inhibition induces Ewing’s sarcoma apoptosis and ferroptosis through NPM1/YAP1 axis
Cell Death & Disease
January 29, 2024
Huimou Chen, Jing Hu, Xilin Xiong, Hongling Chen, Biaojun Lin, Yusong Chen, Yang Li, Di Cheng, Zhihua Li
5 μL of Annexin V-Alexa Fluor 647 and 7-AAD for 5 mins away from light, followed by
flow cytometry
(
SP6800
,
Sony
, Japan) within 1 h.
Western blotting (WB
) The cells were washed with precooled PBS and lysed
(71)
Modular cytosine base editing promotes epigenomic and genomic modifications
Nucleic Acids Research
January 25, 2024
Julian Weischedel, Laurence Higgins, Sally Rogers, Anna Gramalla-Schmitz, Paulina Wyrzykowska, Simone Borgoni, Thomas MacCarthy, Richard Chahwan
For live/dead discrimination cells were incubated with PI. GFP
fluorescence
was detected using a
SONY
SP6800
spectral analyser or BD FACS Fortessa. GFP-negative HEK293A and GFP-positive HEK293T-GFP cells were
(72)
γδ T cells respond directly and selectively to the skin commensal yeast Malassezia for IL-17-dependent fungal control
PLOS Pathogens
January 12, 2024
Fiorella Ruchti, Meret Tuor, Liya Mathew, Neil E McCarthy, Salomé LeibundGut-Landmann
appropriate. All
staining
steps were carried out on ice. Cells were acquired on a Spectral Analyzer
SP6800
(
Sony
) or on a CytoFLEX S (Beckman Coulter), and the data were analyzed with FlowJo software (FlowJo
(73)
A facile approach to preparing personalized cancer vaccines using iron-based metal organic framework
Frontiers in Immunology
January 8, 2024
Xia Li, Shinya Hattori, Mitsuhiro Ebara, Naoto Shirahata, Nobutaka Hanagata
anti-H-2Kb
- SIINFEKL-PE (
BioLegend
) antibodies.
Flow cytometry
was performed using a Spectral Cell Analyzer (
SP6800
,
Sony
). FlowJo software was used for the analysis of
flow cytometry
data. 2.7 Anti-
tumor
experiments
(74)
Beyond 40 fluorescent probes for deep phenotyping of blood mononuclear cells, using spectral technology
Frontiers in immunology
January 1, 2024
Schmutz S, Commere PH, Montcuquet N, Cumano A, Ait-Mansour C, Novault S, Hasan M.
different shapes of emission spectra became possible. With the first available spectral cytometer (
Sony
SP6800
) equipped with two excitation lasers (488nm and 405nm) we built a panel of 19 fluorescent probes that
(75)
Single-cell RNA-sequencing of PBMCs from SAVI patients reveals disease-associated monocytes with elevated integrated stress response
Cell reports. Medicine
December 19, 2023
de Cevins C, Delage L, Batignes M, Riller Q, Luka M, Remaury A, Sorin B, Fali T, Masson C, Hoareau B,
et al
.
extracellular staining
has been performed for 30 min at 4°C protected from light. Samples were analyzed using the
Sony
SP6800
spectral
flow cytometers
. IFN-β stimulation of healthy PBMC Buffy coats from three healthy young male
(76)
Multicenter randomized controlled trial of neoadjuvant chemoradiotherapy alone or in combination with pembrolizumab in patients with resectable or borderline resectable pancreatic adenocarcinoma
J Immunother Cancer
December 1, 2023
Matthew H G Katz, Gina R Petroni, Todd Bauer, Matthew J Reilley, Brian M Wolpin, Chee-Chee Stucky, Tanios S Bekaii-Saab, Rawad Elias, Nipun Merchant, Andressa Dias Costa,
et al.
samples were fixed by adding 100 µL of 1% formalin.
Flow cytometry analysis
was performed using a
SONY
SP6800
Spectral Cell Analyzer (Sony Biotechnology, San Jose, California, USA). Statistical considerations
(77)
Methamphetamine induces a low dopamine transporter expressing immunophenotype without altering total number of peripheral immune cells
Basic & Clinical Pharmacology & Toxicology
November 1, 2023
Adithya Gopinath, Tabish Riaz, Emily Miller, Leah Phan, Aidan Smith, Ohee Syed, Stephen Franks, Luis R. Martinez, Habibeh Khoshbouei
Number,Purpose Centrifuge,Sorvall,ST8,PBMC isolation Cytometer,BD,Canto II,FC Spectral Analyzer,
Sony
,
SP6800
,FC Spectral Analyzer,Cytek,Aurora 5L,FC
Flow cytometer
,
Beckman
,
Cytoflex LX
,"FC, 13-plex
ELISA
" Microcentrifuge,Fisher,59A,FC Equipment
(78)
PI3K/mTOR inhibitors promote G6PD autophagic degradation and exacerbate oxidative stress damage to radiosensitize small cell lung cancer
Cell Death & Disease
October 6, 2023
Huan Deng, Yamei Chen, Li Wang, Yibi Zhang, Qingqing Hang, Peijing Li, Peng Zhang, Jing Ji, Hai Song, Ming Chen,
et al.
at 488 nm. To evaluate the production of ROS MFI values in the live-cell gate were calculated using
SP6800 Spectral Analyzer
(
Sony
Biotechnology). When double peaks appeared, the right peak was believed to be the positive peak
(79)
Preclinical characterization of WB737, a potent and selective STAT3 inhibitor, in natural killer/T‐cell lymphoma
MedComm (2020)
August 1, 2023
Yali Wang, Wenbo Zhou, Jianfeng Chen, Jinghong Chen, Peng Deng, Huang Chen, Yichen Sun, Zhaoliang Yu, Diwen Pang, Lizhen Liu,
et al.
Bioscience) following the manufacturer's instructions. The stained cells were analyzed by
flow cytometry
(
SP6800
,
Sony
) and quantified by FlowJo software (BD Bioscience). 4.9 Colony formation
assay
A total of 2
(80)
T cell migration and effector function differences in familial adenomatous polyposis patients with APC gene mutations
Frontiers in Immunology
July 18, 2023
Céline Cuche, Marta Mastrogiovanni, Marie Juzans, Hélène Laude, Marie-Noëlle Ungeheuer, Daniel Krentzel, Maria Isabella Gariboldi, Daniel Scott-Algara, Marianne Madec, Sophie Goyard,
et al.
cells were analyzed the following day by multiparameter
flow cytometry
using a Spectral
Flow Cytometer
SP6800
or
ID7000
(
Sony
). Data analyses were performed with FlowJo software. Gating strategies for the different
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
SP6800 Spectral Analyzer from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top