Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
SP6800 Spectral Analyzer
Supplier Images
Published Figures
SP6800 Spectral Analyzer
SP6800 Spectral Analyzer from Sony Corporation
Be the first to write a review!
Citations:
(204)
Figures:
(2)
Inquire
from
Sony Corporation for
SP6800 Spectral Analyzer
Description
SP6800 spectral analyzer / flow cytometer uses patented technologies and spectral technology to optimize sensitivity, and simplify multicolor panel design.
Product Specs
Citations
Reviews
Product Specs
Item
SP6800 Spectral Analyzer
Company
Sony Corporation
Price
Inquire
Catalog Number
SP6800
Detection
FSC, SSC, 32-channels (PMT arrays); cell position XY allows up to 64 channels
Lasers
2 or 3 lasers
Excitation
405nm (60mW), 488nm (40mW), 638nm (60mW)
Parameters
64 fluorescence channels
Capacity
Tubes (5 mL)
Data Throughput
10,000 events/sec; 20,000 events/sec (max)
Dimensions
(WxDxH) 60.0 x 63.5 x 71.3 cm
Add to Compare List
Citations (204)
(41)
Phase I study of ribociclib (CDK4/6 inhibitor) with spartalizumab (PD-1 inhibitor) with and without fulvestrant in metastatic hormone receptor-positive breast cancer or advanced ovarian cancer
J Immunother Cancer
February 25, 2025
Ana C Garrido-Castro, Noah Graham, Lestat R Ali, Christina Herold, Jennifer Desrosiers, Khanh Do, Heather Parsons, Tianyu Li, Shom Goel, Molly DiLullo,
et al.
incubation
, the cells were washed and fixed with 1% formalin, then analyzed by
flow cytometry
using a
Sony
SP6800 Spectral Analyzer
. Gating for cell populations of interest was performed with FlowJo software. Changes in cell populations
(42)
Super-enhancer–driven EFNA1 fuels tumor progression in cervical cancer via the FOSL2-Src/AKT/STAT3 axis
J Clin Invest
February 18, 2025
Shu-Qiang Liu, Xi-Xi Cheng, Shuai He, Tao Xia, Yi-Qi Li, Wan Peng, Ya-Qing Zhou, Zi-Hao Xu, Mi-Si He, Yang Liu,
et al.
Fisher Scientific) for 30 minutes at room temperature. Cell cycle distribution was assessed using an
SP6800 Spectral Analyzer
(
Sony
) and analyzed using FlowJo v10 software. Cell apoptosis was evaluated through
flow cytometry
using
(43)
Immunostimulatory Effects of Guanine-Quadruplex Topologies as Scaffolds for CpG Oligodeoxynucleotides
Biomolecules
January 10, 2025
Pathak S, Le NBT, Oyama T, Odahara Y, Momotake A, Ikebukuro K, Kataoka-Hamai C, Yoshikawa C, Kawakami K, Kaizuka Y,
et al
.
PBS, and the mean
fluorescence
intensity (MFI) from Cy5 was quantified using a spectral cell analyzer (
SP6800
,
Sony
, Tokyo, Japan). 2.11.
Confocal Microscopy
The localization of G4 CpG ODNs was examined via
confocal microscopy
(44)
SMAC mimetics induce human macrophages to phagocytose live cancer cells
Immunother Adv
January 1, 2025
Liu SY, Hulsman MPM, Leyendecker P, Chang E, Donovan KA, Strobel F, Dougan J, Fischer ES, Dougan M, Dougan SK,
et al
.
tubes to fix the samples. Tubes were stored at 4°C and protected from light until time of analysis on a
SP6800 Spectral Analyzer
(
Sony
).
Immunoblotting
Differentiated
macrophages
were reseeded in 6-well
tissue culture
-treated plates
(45)
Characterization of naphthoquinones as inhibitors of glutathione reductase and inducers of intracellular oxidative stress
Redox Report
December 31, 2024
Xiaowan Chen, Yan Ma, Ziming Yang, Dingjie Shen, Xia Li, Maowei Ni, Xiaoling Xu, Wei Chen
Reagent for 30 min. The intracellular green
fluorescence
intensity was analyzed by
flow cytometry
(
SP6800
,
SONY
). Data analysis was performed using FlowJo software. 2.10. In vivo study ICR
mice
(5 weeks,
(46)
Bone morphogenetic protein 4 induces hematopoietic stem cell development from murine hemogenic endothelial cells in culture
Stem cell reports
December 10, 2024
Tsuruda M, Morino-Koga S, Zhao X, Usuki S, Yasunaga KI, Yokomizo T, Nishinakamura R, Suda T, Ogawa M.
TER119, CD4, CD8a, CD11b, and Gr-1. After
staining
dead cells with PI, cells were analyzed using an
SP6800
spectral cell analyzer (
SONY
). In some experiments, Lin− KIT+ Sca-1+ KSL cells were sorted using the
(47)
Targeted immune cell therapy for hepatocellular carcinoma using expanded liver mononuclear cell-derived natural killer cells
Neoplasia
December 1, 2024
Xin Hu, Yifang Shui, Seiichi Shimizu, Seisuke Sakamoto, Mureo Kasahara, Seiji Okada, Wen-Zhi Guo, Masayuki Fujino, Xiao-Kang Li
using either a
BD FACSymphony
™ (
BD Biosciences
, San Diego, CA) or a SONY Spectral Cell Analyzer LE-
SP6800
(
Sony
, Tokyo, Japan). Data analyses were conducted using the FlowJo software program (version 10.5.0;
(48)
Sublingual immune cell clusters and dendritic cell distribution in the oral cavity
JCI Insight
November 8, 2024
Yutaka Kusumoto, Mizuki Ueda, Mayuko Hashimoto, Haruka Takeuchi, Naoko Okada, Junya Yamamoto, Akiko Nishii, Atsuki Fujino, Akiho Kurahashi, Momoka Satoh,
et al.
stained with fluorochrome-conjugated mAbs shown in Supplemental Table 2 and analyzed by
flow cytometry
(
SP6800
,
SONY
). KikGR+ clusters in CD11c-KikGR
mice
were photolabeled and analyzed in the same way as above.
(49)
SUV39H1 epigenetically modulates the MCPIP1-AURKA signaling axis to enhance neuroblastoma tumorigenesis
Oncogene
November 4, 2024
Mengzhen Li, Feifei Sun, Juan Wang, Suying Lu, Yi Que, Mengjia Song, Huimou Chen, Xiangyu Xiong, Weiji Xie, Jia Zhu,
et al.
the dark, then 10 μL of 7-AAD was added into each tube, immediately analyzed with the
flow cytometry
(
SP6800
,
Sony
, Japan) within 1 h. Cell cycle analysis The cell cycle phases of NB cells were analyzed by
flow cytometry
(50)
Mechanism of Drug Resistance to First‐Line Chemotherapeutics Mediated by TXNDC17 in Neuroblastomas
Cancer Rep (Hoboken)
October 16, 2024
Chenggong Zeng, Zhuoran Li, Zhiqing Wei, Tingting Chen, Juan Wang, Junting Huang, Feifei Sun, Jia Zhu, Suying Lu, Zijun Zhen
FXP018‐100), and single‐dye tubes were prepared. The samples were analyzed by spectral
flow cytometer
SP6800
(
Sony
Biotechnology, San Jose, CA, USA). 2.6
Western Blot
Proteins were extracted from
tumor
cells
(51)
Obesity intensifies sex-specific interferon signaling to selectively worsen central nervous system autoimmunity in females
Cell Metabolism
October 1, 2024
Brendan Cordeiro, Jeeyoon Jennifer Ahn, Saurabh Gawde, Carmen Ucciferri, Nuria Alvarez-Sanchez, Xavier S. Revelo, Natalie Stickle, Kaylea Massey, David G. Brooks, Joel M. Guthridge,
et al.
in 1 x FACS buffer for acquisition. Cells were acquired either on an LSR II (
BD Biosciences
) or
Sony
SP6800
and were analyzed using FlowJo (TreeStar). OneComp eBeads Compensation Beads (Invitrogen) were used
(52)
Human IL-22 receptor-targeted small protein antagonist suppress murine DSS-induced colitis
Cell Communication and Signaling
October 1, 2024
Milan Kuchař, Kristýna Sloupenská, Leona Rašková Kafková, Yaroslava Groza, Jozef Škarda, Petr Kosztyu, Marie Hlavničková, Joanna M. Mierzwicka, Radim Osička, Hana Petroková,
et al.
plate was incubated for 30 min at RT. After washing, beads were analyzed using
flow cytometer
SONY
SP6800
(Sony, Tokio, Japan).
Histochemistry
Formalin-fixed, paraffin embedded
tissues were cut, stained with
(53)
CD226 implicated in Akt-dependent apoptosis of CD4+ T cell contributes to asthmatic pathogenesis
Cell Death & Disease
September 30, 2024
Yuan Zhang, Yang Xie, Xuexin Zhang, Chujun Duan, Jingchang Ma, Yuling Wang, Yilin Wu, Niqi Shan, Kun Cheng, Ran Zhuang,
et al.
(
Thermo Fisher Scientific
) according to the manufacturer’s instructions. Data were acquired using a
Sony
SP6800 Spectral Analyzer
(Sony Biotechnology, UK) and the NovoExpress software.
Apoptosis assay
Cellular apoptosis was detected
(54)
CSF1R Ligands Expressed by Murine Gliomas Promote M-MDSCs to Suppress CD8(+) T Cells in a NOS-Dependent Manner
Cancers
September 1, 2024
Takacs GP, Garcia JS, Hodges CA, Kreiger CJ, Sherman A, Harrison JK.
centrifuged twice (500× g, 5 min, RT). All samples were analyzed by single-color compensation on a
Sony
SP6800 spectral analyzer
. Data were quantified using FlowJo V10.8.1 (BD Biosciences, Franklin Lakes, NJ, USA). Flow gating strategy
(55)
Single-cell profiling of surface glycosphingolipids opens a new dimension for deconvolution of breast cancer intratumoral heterogeneity and phenotypic plasticity
Journal of Lipid Research
September 1, 2024
Jiřina Procházková, Radek Fedr, Barbora Hradilová, Barbora Kvokačková, Josef Slavík, Ondrej Kováč, Miroslav Machala, Pavel Fabian, Jiří Navrátil, Simona Kráčalíková,
et al.
cells were resuspended in 200 μl of
staining
buffer and analyzed using Spectral Cell Analyzer
SONY
SP6800
(Sony Biotechnology). Panels with antibodies and isotype controls are listed in supplemental Table S3.
(56)
19Fluorine‐MRI Based Longitudinal Immuno‐Microenvironment‐Monitoring for Pancreatic Cancer
Journal of Magnetic Resonance Imaging
August 27, 2024
Wilfried Reichardt, Tabea Gewalt, Philipp Hafner, Steffen J. Keller, Xun Chen, Asma Alrawashdeh, Yayu Li, Solène Besson, Stefan Fichtner‐Feigl, Dominik von Elverfeldt,
et al.
Fix/Perm wash (BD) at room temperature.
Flow cytometry
was performed on the Sony Spectral Analyzer
SP6800
(
Sony
Biotechnology, San Jose, CA, USA), and analyzed using FlowJo software (BD Biosciences, Ashland,
(57)
Pre-existing cell subpopulations in primary prostate cancer tumors display surface fingerprints of docetaxel-resistant cells
Cell Oncol (Dordr)
August 20, 2024
Stanislav Drápela, Barbora Kvokačková, Eva Slabáková, Anna Kotrbová, Kristína Gömöryová, Radek Fedr, Daniela Kurfürstová, Martin Eliáš, Vladimír Študent jr, Frederika Lenčéšová,
et al.
leukocytes
, endothelial-like cells, and
stromal cells
[22, 23]. Samples were analyzed using a
SONY
SP6800
Spectral Cell Analyzer (SONY, Japan). Acquired FCS files were exported and analyzed using FlowJo software
(58)
NADPH oxidase-dependent free radical generation and protein adduct formation in neutrophils†
RSC Advances
August 5, 2024
Renuka Ramalingam Manoharan, Kateřina Zachová, Marek Buzáš, Pavel Pospíšil, Michal Křupka, Ankush Prasad
Flow cytometric analysis
Cell differentiation
was assessed by evaluating the expression of surface CD markers using an
SP6800
spectral cell analyzer (
Sony
Biotechnology, San Jose, California, USA) equipped with 405 nm, 488 nm
(59)
PIK3CA inhibition in models of proliferative glomerulonephritis and lupus nephritis
Journal of Clinical Investigation
August 1, 2024
Junna Yamaguchi, Pierre Isnard, Noémie Robil, Pierre de la Grange, Clément Hoguin, Alain Schmitt, Aurélie Hummel, Jérôme Megret, Nicolas Goudin, Marine Luka,
et al.
information, please refer to the Supplemental Methods.
Flow cytometry
was performed using the
Sony
SP6800
Spectral Cell Analyzer, and data were analyzed with FlowJo software (TreeStar). Preparation of single-cell
(60)
Metabolic adaptation pilots the differentiation of human hematopoietic cells
Life Science Alliance
August 1, 2024
Laëtitia Racine, Romuald Parmentier, Shreyas Niphadkar, Julie Chhun, Jean-Alain Martignoles, François Delhommeau, Sunil Laxman, Andras Paldi
7-aminoactinomycin D marker (Invitrogen). The
fluorescence
intensity of CTV and antibodies was measured with the
SP6800
cytometer (
Sony
) from the ImCy platform (Généthon).
Cytometry
on long-term cultures
Cytometry
results
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
SP6800 Spectral Analyzer from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top