Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Automated DNA/RNA Purification Sample Preparation Workstations
Maxwell RSC Instrument
Supplier Images
Published Figures
Maxwell RSC Instrument
Maxwell RSC Instrument
Maxwell RSC Instrument from Promega
Be the first to write a review!
Citations:
(802)
Figures:
(1)
Supplier Page
Supplier Page from
Promega for
Maxwell RSC Instrument
Get Pricing
Ask a Question
Description
The Maxwell RSC Instrument is a platform for automated extraction of nucleic acid from a range of sample types. Extraction methods use sample lysis and binding to paramagnetic particles followed by washing steps and elution.
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
Maxwell RSC Instrument
Company
Promega
Price
Supplier Page
View Company Product Page
Catalog Number
AS4500
Quantity
EA
Processing Time
30 to 60 min (depending on sample type and method)
Capacity
Up to 16
Dimensions
(WxDxH) 330.2 x 345.2 x 299.7 mm (13 x 13.6 x 11.8 in)
UV Lamp
Avg. lifetime approximately 6,000 hrs
Molecular Weight
~85kDa
Add to Compare List
Promega
2800 Woods Hollow Rd
Madison
,
WI
53711
United States
Phone
: Tel: +1 (608) 274-4330
Fax: +1 (608) 277-2516
Email: custserv@promega.com
techserv@promega.com
Company Profile
Website:
http://www.promega.com
Citations (802)
(701)
Comparison of Abbott ID Now, DiaSorin Simplexa, and CDC FDA Emergency Use Authorization Methods for the Detection of SARS-CoV-2 from Nasopharyngeal and Nasal Swabs from Individuals Diagnosed with COVID-19
Journal of Clinical Microbiology
July 23, 2020
Daniel D. Rhoads, Sree S. Cherian, Katharine Roman, Lisa M. Stempak, Christine L. Schmotzer, Navid Sadri
using 7500 Fast instead of 7500 Fast Dx instrument, (ii) using an alternate RNA extraction method (
Maxwell RSC instrument
with viral TNA kit [catalog no.
AS1330
;
Promega
, Madison, WI, USA]), and (iii) interpreting “inconclusive”
(702)
Expression of NANOG and Its Regulation in Oral Squamous Cell Carcinoma
BioMed Research International
July 18, 2020
Gašper Grubelnik, Emanuela Boštjančič, Aleš Grošelj, Nina Zidar
Maxwell® RSC Tissue DNA Kit
(
Promega Corporation
, Madison, USA). Automatic isolation was performed using
Maxwell® RSC Instrument
(
Promega Corporation
, Madison, USA), according to the manufacturer's instructions. All the reagents
(703)
Mitochondrial PCK2 Missense Variant in Shetland Sheepdogs with Paroxysmal Exercise-Induced Dyskinesia (PED)
Genes (Basel)
July 9, 2020
Jasmin Nessler, Petra Hug, Paul J. J. Mandigers, Peter A. J. Leegwater, Vidhya Jagannathan, Anibh M. Das, Marco Rosati, Kaspar Matiasek, Adrian C. Sewell, Marion Kornberg,
et al.
from the EDTA blood of affected
dogs
and healthy controls with the Maxwell RSC Whole Blood Kit using a
Maxwell RSC instrument
(
Promega
, Dübendorf, Switzerland). Illumina TruSeq
PCR
-free DNA libraries with 350 bp insert size of
(704)
Cancer of Unknown Primary ( CUP ): genetic evidence for a novel nosological entity? A case report
EMBO Molecular Medicine
July 7, 2020
Silvia Benvenuti et al.
three different regions of each
metastases
retrieved at warm
autopsy
and stored in RNAlater solution by
Maxwell® RSC Instrument
(
Promega
) using
Maxwell® RSC miRNA Tissue Kit
(
Promega
). Quantification was performed on a Bioanalyzer
(705)
Microbiota in Waterlogged Archaeological Wood: Use of Next-Generation Sequencing to Evaluate the Risk of Biodegradation
Applied Sciences
July 4, 2020
Federica Antonelli, Alfonso Esposito, Giulia Galotta, Barbara Davidde Petriaggi, Silvano Piazza, Manuela Romagnoli, Francesca Guerrieri
samples were processed by the two different kits and total genomic microbial DNA was extracted with
Maxwell®RSC Instrument
(
Promega Corporation
, Madison, WI, USA) Appl. Sci. 2020, 10, 4636 4 of 21 Table 2. List of samples
(706)
Leukocyte Telomere Length and Its Interaction with Germline Variation in Telomere-Related Genes in Relation to Pancreatic Adenocarcinoma Risk
Cancer Epidemiology, Biomarkers & Prevention
July 1, 2020
Samuel O. Antwi, William R. Bamlet, Kari G. Rabe, Richard M. Cawthon, Isoken Umudi, Brooke R. Druliner, Hugues Sicotte, Ann L. Oberg, Aminah Jatoi, Lisa A. Boardman,
et al.
buffy coat
leukocytes
stored at −80°C until DNA extraction. DNA extraction was performed using the
Maxwell® RSC Instrument
with appropriate kits (
Promega
) and quantitated using a Qubit Fluorometer. Details of the methods used
(707)
Seroprevalence and B1 gene Phylogeny of Toxoplasma gondii of Dogs and Cats in Republic of Korea
The Korean Journal of Parasitology
June 26, 2020
Yeojin Park, Jinhyeong Noh, Hyun-Ji Seo, Keun-Ho Kim, Subin Min, Mi-Sun Yoo, Bo-Ram Yun, Jong-Ho Kim, Eun-Jin Choi, Doo-Sung Cheon,
et al.
of Maxwell® RSC Whole Blood and Viral TNA Kit (Promega, Madison, Wisconsin, USA), respectively, and
Maxwell® RSC Instrument
(
Promega
). The cartridges to be used were placed in the deck tray(s). Each cartridge in the deck tray(s)
(708)
Pazopanib and Trametinib as a Synergistic Strategy against Osteosarcoma: Preclinical Activity and Molecular Insights
Cancers (Basel)
June 10, 2020
Giulia Chiabotto et al.
1-Thioglycerol/Homogenization Solution. RNA samples were prepared following the manufacturer’s instructions of
Maxwell® RSC Instrument
. RNA purity (
DeNovix
DS-11+ Spectrophotometer
, DeNovix Inc., Wilmington, DE, USA), concentration (
Qubit®3.0 Fluorometer
(709)
Impact of mRNA chemistry and manufacturing process on innate immune activation
Science advances
June 1, 2020
Nelson J, Sorensen EW, Mintri S, Rabideau AE, Zheng W, Besin G, Khatwani N, Su SV, Miracco EJ, Issa WJ,
et al
.
using ZR
BashingBead
Lysis Tubes (
Zymo Research
, Irvine, CA, USA). RNA was isolated using automated
Maxwell RSC Instrument
with simplyRNA Tissue Kit as per the manufacturer’s recommendations (
Promega
Corp., Madison, WI, USA).
(710)
Comparison of mutation profile between primary phyllodes tumors of the breast and their paired local recurrences
Polish Journal of Pathology
May 21, 2020
Jerzy Mitus, Agnieszka Adamczyk, Kaja Majchrzyk, Artur Kowalik, Janusz RyÅ›, Joanna Niemiec
component DNA was isolated separately. DNA was obtained from tissue sections using a semi-automatic method with
Maxwell® RSC Instrument
(
Promega
). The
Maxwell® RSC DNA FFPE Kit
(
Promega
) was used to isolate genomic DNA using paramagnetic
(711)
Flooding Stress and High-Pressure Treatment Enhance the GABA Content of the Vegetable Soybean (Glycine max Merr.)
Agriculture
May 15, 2020
Man-Shin Shiu, Yuan-Tay Shyu, Sz-Jie Wu
Madison, WI, USA) in accordance with the manufacturer’s instructions. Total RNA was extracted using the
Maxwell® RSC Instrument
(
Promega
, Madison, WI, USA), and reverse transcription was performed using the GoScriptTM Reverse Transcription
(712)
A DSG1 Frameshift Variant in a Rottweiler Dog with Footpad Hyperkeratosis
Genes (Basel)
April 24, 2020
Katherine A. Backel, Sarah Kiener, Vidhya Jagannathan, Margret L. Casal, Tosso Leeb, Elizabeth A. Mauldin
DNA Extraction Genomic DNA was isolated from EDTA blood with the Maxwell RSC Whole Blood Kit using a
Maxwell RSC instrument
(
Promega
, Dübendorf, Switzerland). 2.5.
Whole-Genome Sequencing
An Illumina TruSeq
PCR
-free DNA library
(713)
Inhibition of miR‑18a‑3p reduces proliferation of mesothelioma cells and sensitizes them to cisplatin
Oncology Letters
April 1, 2020
Rui Suzuki, Vishwa Jeet Amatya, Kei Kushitani, Yuichiro Kai, Takahiro Kambara, Yutaro Fujii, Yukio Takeshima
transfected
with the miRNA inhibitor or control using a
Maxwell RSC simplyRNA Cells kit
and analyzed on a
Maxwell RSC Instrument
(
Promega
) according to the manufacturer's instructions. The extracted RNA was reverse‑transcribed with
SuperScript IV VILO Master Mix
(714)
Nanostructured recombinant protein particles raise specific antibodies against the nodavirus NNV coat protein in sole
Fish & Shellfish Immunology
April 1, 2020
Rosemary Thwaite, Concepción Berbel, Manuel Aparicio, Debora Torrealba, Mireia Pesarrodona, Antonio Villaverde, Juan José Borrego, Manuel Manchado, Nerea Roher
well and RNA was extracted in an automated
nucleic acid purification
system including DNAse treatment (
Maxwell RSC Instrument
,
Promega
). RNA was eluted in 45 µL of nuclease free water. RNA yield and quality were determined on
(715)
Modulation of Nqo1 activity intercepts anoikis resistance and reduces metastatic potential of hepatocellular carcinoma
Cancer science
April 1, 2020
Shimokawa M, Yoshizumi T, Itoh S, Iseda N, Sakata K, Yugawa K, Toshima T, Harada N, Ikegami T, Mori M.
Gene expression analysis
Total RNA was extracted from
cultured cells
or surgically obtained tissues using the
Maxwell RSC Instrument
(
Promega
) and reverse‐transcribed using SuperScriptIII (Invitrogen) following the manufacturers’ instructions.
(716)
Divergent northern and southern populations and demographic history of the pearl oyster in the western Pacific revealed with genomic SNPs
Evolutionary Applications
April 1, 2020
Takeshi Takeuchi, Tetsuji Masaoka, Hideo Aoki, Ryo Koyanagi, Manabu Fujie, Noriyuki Satoh
sequencing
Genomic DNA was extracted from tissues using a
Maxwell® RSC Blood DNA Kit
(
Promega
) on a
Maxwell® RSC Instrument
(
Promega
), according to the manufacturer's standard protocol. Then, it was quantified using a NanoDrop™
(717)
Polyphenols from grape pomace induce osteogenic differentiation in mesenchymal stem cells
International Journal of Molecular Medicine
March 30, 2020
Elisa Torre, Giorgio Iviglia, Clara Cassinelli, Marco Morra, Nazario Russo
RNA was isolated from hMSCs using the Maxwell® RSC simply RNA Cells kit (Promega Corporation) in the
Maxwell® RSC instrument
(
Promega Corporation
), following the manufacturer's protocol.
RNA quantification
was performed using
(718)
YARS2 Missense Variant in Belgian Shepherd Dogs with Cardiomyopathy and Juvenile Mortality
Genes (Basel)
March 14, 2020
Corinne Gurtner, Petra Hug, Miriam Kleiter, Kernt Köhler, Elisabeth Dietschi, Vidhya Jagannathan, Tosso Leeb
DNA Extraction Genomic DNA was isolated from EDTA blood with the Maxwell RSC Whole Blood Kit using a
Maxwell RSC instrument
(
Promega
, Dübendorf, Switzerland). 2.5. Linkage and Homozygosity Mapping Five
dogs
from one Malinois
(719)
Genetic Identification and Transcriptome Analysis of Lintless and Fuzzless Traits in Gossypium arboreum L.
International Journal of Molecular Sciences
February 29, 2020
Xueying Liu, Philippe Moncuquet, Qian-Hao Zhu, Warwick Stiller, Zhengsheng Zhang, Iain Wilson
ZI #1, and BM13H at 0, 1, 3, and 5 dpa were extracted using the
Maxwell RSC Plant RNA kit
with the
Maxwell RSC Instrument
(
Promega
). Each sample included three biological replicates. The quality of the RNA samples was checked
(720)
Histogram Analysis of Diffusion Weighted Imaging in Low-Grade Gliomas: in vivo Characterization of Tumor Architecture and Corresponding Neuropathology
Frontiers in Oncology
February 25, 2020
Georg Alexander Gihr, Diana Horvath-Rizea, Elena Hekeler, Oliver Ganslandt, Hans Henkes, Karl-Titus Hoffmann, Cordula Scherlach, Stefan Schob
paraffin-embedded tissue
blocks using the
Maxwell® RSC FFPE Plus DNA Kit
AS1720
(
Promega
, USA) with a
Maxwell® RSC Instrument
(
Promega
, USA), followed by conversion of unmethylated cytosine residues to uracil by bisulfite treatment