Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
Antibody Discovery
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
MA900 Multi-Application Cell Sorter
Supplier Images
Published Figures
MA900 Multi-Application Cell Sorter
MA900 Multi-Application Cell Sorter from Sony Corporation
Be the first to write a review!
Citations:
(989)
Figures:
(7)
Inquire
from
Sony Corporation for
MA900 Multi-Application Cell Sorter
Description
MA900 multi-application cell sorter features ease of use, support for up to 12 fluorescence parameters and 4-way sorting.
Product Specs
Citations
Reviews
Product Specs
Item
MA900 Multi-Application Cell Sorter
Company
Sony Corporation
Price
Inquire
Catalog Number
MA900
Lasers
2 lasers
Excitation
405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), 561 nm (36 mW)
Parameters
14 parameters / 12 fluorescence channels
Capacity
Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
Data Throughput
70,000 events/sec (max)
Dimensions
(WxDxH) 55 x 55 x 72 cm
Add to Compare List
Citations (989)
(821)
Tuned activation of MSLN-CAR T cells induces superior antitumor responses in ovarian cancer models
Journal for ImmunoTherapy of Cancer
February 1, 2023
Esther Schoutrop, Thomas Poiret, Ibrahim El-Serafi, Ying Zhao, Rui He, Alina Moter, Johan Henriksson, Moustapha Hassan, Isabelle Magalhaes, Jonas Mattsson
were sorted using
Fluorescence-Activated Cell Sorting
(FACS) (
BD
FACSAria
, Becton Dickinson and
SONY
MA900
cell sorter, Sony Biotechnology). MSLN+GFP+/ffLuc+ OVCAR-4 and SKOV-3 cells were assessed for microbiology
(822)
Engineered PROTAC-CID Systems for Mammalian Inducible Gene Regulation
Journal of the American Chemical Society
January 25, 2023
Ma D, Yuan Q, Peng F, Paredes V, Zeng H, Osikpa EC, Yang Q, Peddi A, Patel A, Liu MS,
et al
.
Cells were transferred into 12×75 mm flow tubes (Global Scientific no. 110410). Cells were analyzed by
MA900
flow cytometry
(
SONY
). 405 nm laser (FL6 filter) was used for testing the BFP channel. 488 nm (FL1 filter)
(823)
mTOR regulates T cell exhaustion and PD-1–targeted immunotherapy response during chronic viral infection
Journal of Clinical Investigation
January 17, 2023
Satomi Ando, Charles M. Perkins, Yamato Sajiki, Chase Chastain, Rajesh M. Valanparambil, Andreas Wieland, William H. Hudson, Masao Hashimoto, Suresh S. Ramalingam, Gordon J. Freeman,
et al.
vivo resting, Thy1.1+ transduced P14 cells were sorted by a FACSAria II, FACSAria Fusion, SH800S, or
MA900
(
Sony
Biotechnology). As a control, nontransduced P14 cells were prepared using the same method without
(824)
mTOR regulates T cell exhaustion and PD-1–targeted immunotherapy response during chronic viral infection
J Clin Invest
January 17, 2023
Satomi Ando, Charles M. Perkins, Yamato Sajiki, Chase Chastain, Rajesh M. Valanparambil, Andreas Wieland, William H. Hudson, Masao Hashimoto, Suresh S. Ramalingam, Gordon J. Freeman,
et al.
vivo resting, Thy1.1+ transduced P14 cells were sorted by a FACSAria II, FACSAria Fusion, SH800S, or
MA900
(
Sony
Biotechnology). As a control, nontransduced P14 cells were prepared using the same method without
(825)
The Notch1/CD22 signaling axis disrupts Treg cell function in SARS-CoV2-associated multisystem inflammatory syndrome in children
Journal of Clinical Investigation
January 3, 2023
Mehdi Benamar, Qian Chen, Janet Chou, Amélie M. Julé, Rafik Boudra, Paola Contini, Elena Crestani, Peggy S. Lai, Muyun Wang, Jason Fong,
et al.
In vitro
Notch1 induction
Human
Tregs from healthy donors were isolated by
cell sorting
(
Sony
Sorter,
MA900
) based on
CD3
, CD4, CD25hi, and CD127lo expression. Tregs were seeded at 1 × 104 cells in 96-well plates
(826)
Use of a dual genetic system to decipher exocrine cell fate conversions in the adult pancreas
Cell discovery
January 3, 2023
Zhao H, Huang X, Liu Z, Lai L, Sun R, Shen R, Li Y, He L, Pu W, Lv Z,
et al
.
Then
flow cytometry
experiments were performed using the
Beckman
Cytoflex LX
or sorted using the
Sony
MA900
flow cytometer
. Single-cell RNA sequencing Single-cell RNA sequencing was performed as previously27.
(827)
The Notch1/CD22 signaling axis disrupts Treg function in SARS-CoV-2–associated multisystem inflammatory syndrome in children
J Clin Invest
January 3, 2023
Mehdi Benamar, Qian Chen, Janet Chou, Amélie M. Julé, Rafik Boudra, Paola Contini, Elena Crestani, Peggy S. Lai, Muyun Wang, Jason Fong,
et al.
In vitro
Notch1 induction
Human
Tregs from healthy donors were isolated by
cell sorting
(
Sony
Sorter,
MA900
) based on
CD3
, CD4, CD25hi, and CD127lo expression. Tregs were seeded at 1 × 104 cells in 96-well plates
(828)
Human type I IFN deficiency does not impair B cell response to SARS-CoV-2 mRNA vaccination
Journal of Experimental Medicine
January 2, 2023
Aurélien Sokal, Paul Bastard, Pascal Chappert, Giovanna Barba-Spaeth, Slim Fourati, Alexis Vanderberghe, Pauline Lagouge-Roussey, Isabelle Meyts, Adrian Gervais, Magali Bouvier-Alias,
et al.
(
Thermo Fisher Scientific
,
1:200
) incubated with conjugated antibodies. Samples were acquired using an
MA900
(
Sony
). For
cell sorting
, cells were stained using the same protocol and then sorted in 96 plates using
(829)
Tissue-specific melt electrowritten polymeric scaffolds for coordinated regeneration of soft and hard periodontal tissues
Bioactive materials
January 1, 2023
Daghrery A, Ferreira JA, Xu J, Golafshan N, Kaigler D, Bhaduri SB, Malda J, Castilho M, Bottino MC.
assess the presence and expression of
mesenchymal stem cell
(MSC) surface markers,
flow cytometry
(
MA900
Cell Sorter,
Sony Biotechnology
Inc., San Jose, CA, USA) was performed following the criteria recommended
(830)
Dantrolene inhibits lysophosphatidylcholine-induced valve interstitial cell calcific nodule formation via blockade of the ryanodine receptor
Frontiers in cardiovascular medicine
January 1, 2023
Sylvester CB, Amirkhosravi F, Bortoletto AS, West WJ 3rd, Connell JP, Grande-Allen KJ.
HHBSS without calcium or magnesium, and fluorescent intensity was examined using
flow cytometry
in an
MA900
Cell Sorter (
Sony
). Median
fluorescence
intensity (MFI) was used to determine changes in ROS production.
(831)
Pexidartinib synergize PD-1 antibody through inhibiting treg infiltration by reducing TAM-derived CCL22 in lung adenocarcinoma
Frontiers in pharmacology
January 1, 2023
Zhang W, Jiang X, Zou Y, Yuan L, Wang X.
10.0 was used for data analysis. For
T cell
sorting, the CD3+
CD45
+ cells were collected using
SONY
MA900
(Sony, Tokyo, Japan). An example of the gating strategy is given in Supplementary Figure S1. Anti-
F4/80
(832)
Enhancing adoptive T-cell therapy with fucoidan-based IL-2 delivery microcapsules
Bioengineering & translational medicine
January 1, 2023
Jeon EY, Choi DS, Choi S, Won JY, Jo Y, Kim HB, Jung Y, Shin SC, Min H, Choi HW,
et al
.
isolation kit and CD4+T,
CD8
+T, and regulatory T (
Treg) cells
were then sorted by
flow cytometry
using an
MA900
cell sorter (
SONY
). Sorted
T cells
were stained with CellTrace
Violet
(CTV; Invitrogen) and stimulated
(833)
Gut lumen-leaked microbial DNA causes myocardial inflammation and impairs cardiac contractility in ageing mouse heart
Frontiers in immunology
January 1, 2023
Gao H, Wang K, Suarez JA, Jin Z, Rocha KCE, Zhang D, Farrell A, Truong T, Tekin Y, Tan B,
et al
.
CD45
+
Clec4f
+
F4/80
+ cells, and cardiac
macrophages
were
CD45
+
CD11b
+
F4/80
+ cells. These cells were analyzed by an
MA900
flow cytometer
(
SONY
). Data were analyzed using Flowjo software.
Clec4f
(Cat. No.
156804
),
F4/80
(Cat.
(834)
PEAC-seq adopts Prime Editor to detect CRISPR off-target and DNA translocation
Nature Communications
December 12, 2022
Zhenxing Yu, Zhike Lu, Jingjing Li, Yingying Wang, Panfeng Wu, Yini Li, Yangfan Zhou, Bailun Li, Heng Zhang, Yingzheng Liu,
et al.
by Lipofectamine 3000. The post-
transfection
cells were collected after 48 h. The cell sorter (
SONY
MA900
) was used to sort about 100,000 GFP-positive cells (Supplementary Fig. 14). About 500 ng extracted gDNA
(835)
Meteorin-like is an injectable peptide that can enhance regeneration in aged muscle through immune-driven fibro/adipogenic progenitor signaling
Nature communications
December 9, 2022
Lee DE, McKay LK, Bareja A, Li Y, Khodabukus A, Bursac N, Taylor GA, Baht GS, White JP.
were positively gated before analysis of PB-AnnexinV.
Flow cytometry
and FACS were performed on
Sony
MA900
cell sorter equipped with four lasers and appropriate detector filter sets.
Cell sorting
was performed
(836)
CX3CR1 deficiency aggravates amyloid driven neuronal pathology and cognitive decline in Alzheimer’s disease
Molecular Neurodegeneration
December 1, 2022
Shweta S. Puntambekar et al.
with PE-conjugated α-CD11b (M1/20) antibodies. CD11b+
microglial cells
were purified using the
Sony
MA900
cell sorter. FACS purified cell populations were recovered by
centrifugation
at 400 × g for 7 min at
(837)
Endocardium-to-coronary artery differentiation during heart development and regeneration involves sequential roles of Bmp2 and Cxcl12/Cxcr4
Developmental cell
November 21, 2022
D'Amato G, Phansalkar R, Naftaly JA, Fan X, Amir ZA, Rios Coronado PE, Cowley DO, Quinn KE, Sharma B, Caron KM,
et al
.
(1.1 μM) was added to the cells immediately before FACS. Once stained, the cells were sorted on a
Sony
MA900
cell sortrer into 1.5 ml tubes. The gates were set up to sort cells with low DAPI, low
Cd45
(hematopoietic
(838)
MACHETE identifies interferon-encompassing chromosome 9p21.3 deletions as mediators of immune evasion and metastasis
Nature Cancer
November 7, 2022
Francisco M. Barriga, Kaloyan M. Tsanov, Yu-Jui Ho, Noor Sohail, Amy Zhang, Timour Baslan, Alexandra N. Wuest, Isabella Del Priore, Brigita Meškauskaitė, Geulah Livshits,
et al.
electroporation
. In the case of
fluorescence
reporters, cells were sorted 48 h after
electroporation
(
Sony
MA900
) and further enriched for stable expression 1 week after this initial sort. Selected cells were expanded
(839)
Functional antibodies exhibit light chain coherence
Nature
November 1, 2022
Jaffe DB, Shahi P, Adams BA, Chrisman AM, Finnegan PM, Raman N, Royall AE, Tsai F, Vollbrecht T, Reyes DS,
et al
.
as per_cell_stuff) were run on a MacBook Pro with 16 GB of memory.
Flow cytometry
We used a
Sony
MA900
cell sorter to purify single B cell suspensions from PBMCs from the four donors described in this paper.
(840)
SARS-CoV-2 hijacks macropinocytosis to facilitate its entry and promote viral spike-mediated cell-to-cell fusion
The Journal of biological chemistry
November 1, 2022
Zhang YY, Liang R, Wang SJ, Ye ZW, Wang TY, Chen M, Liu J, Na L, Yang YL, Yang YB,
et al
.
10 min. Cells were resuspended in PBS for
fluorescence-activated cell sorting
analysis with a
SONY
-
MA900
Flow Cell Sorter System.
Assays
were performed in triplicate, and the results are displayed as the percentage
Page
<<
<
41
42
43
44
45
>
>>
Reviews
Be the First to Write a Review!
MA900 Multi-Application Cell Sorter from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top