Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
Antibody Discovery
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
MA900 Multi-Application Cell Sorter
Supplier Images
Published Figures
MA900 Multi-Application Cell Sorter
MA900 Multi-Application Cell Sorter from Sony Corporation
Be the first to write a review!
Citations:
(989)
Figures:
(7)
Inquire
from
Sony Corporation for
MA900 Multi-Application Cell Sorter
Description
MA900 multi-application cell sorter features ease of use, support for up to 12 fluorescence parameters and 4-way sorting.
Product Specs
Citations
Reviews
Product Specs
Item
MA900 Multi-Application Cell Sorter
Company
Sony Corporation
Price
Inquire
Catalog Number
MA900
Lasers
2 lasers
Excitation
405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), 561 nm (36 mW)
Parameters
14 parameters / 12 fluorescence channels
Capacity
Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
Data Throughput
70,000 events/sec (max)
Dimensions
(WxDxH) 55 x 55 x 72 cm
Add to Compare List
Citations (989)
(901)
T-cell CX3CR1 expression as a dynamic blood-based biomarker of response to immune checkpoint inhibitors
Nature Communications
December 1, 2021
Takayoshi Yamauchi et al.
(
BD Biosciences
), or
BD
FACSARIA
II Cell sorter with BD FACSDiva software v8.0 (BD Biosciences) or
MA900 Multi-Application Cell Sorter
(
Sony Biotechnology
Inc.) and data analyzed with FlowJo software v10.1.5 (TreeStar). For TCR
sequencing
(902)
Optimized CRISPR tools and site-directed transgenesis towards gene drive development in Culex quinquefasciatus mosquitoes
Nature Communications
December 1, 2021
Xuechun Feng, Víctor López Del Amo, Enzo Mameli, Megan Lee, Alena L. Bishop, Norbert Perrimon, Valentino M. Gantz
sorting.
Fluorescence-activated cell sorting
(FACS) of
transfected
cells
Cell sorting
was performed in a
Sony
MA900 Multi-Application Cell Sorter
(Department of Genetics, Harvard Medical School) using a 100-μm sorting chip and average flow rate of
(903)
Neurodevelopmental signatures of narcotic and neuropsychiatric risk factors in 3D human-derived forebrain organoids
Molecular psychiatry
December 1, 2021
Notaras M, Lodhi A, Barrio-Alonso E, Foord C, Rodrick T, Jones D, Fang H, Greening D, Colak D.
Iodide (PI;
Thermofisher
, Material#:
P3566
), and analyzed for single-cell DNA content utilizing a
Sony
MA900
cell analysis cytometer. Cell-cycle was subsequently modeled post hoc in the FloJo
cytometry
analysis
(904)
Identification of pathogenic variants in cancer genes using base editing screens with editing efficiency correction
Genome Biology
December 1, 2021
Changcai Huang, Guangyu Li, Jiayu Wu, Junbo Liang, Xiaoyue Wang
Fluorescent-activated
cell sorting
(FACS) was performed to sort 1 N ploidy according to the lowest Hoechst peak using a
MA900
cell sorter (
Sony Biotechnology
). Lentivirus production HEK293T cells were grown on 150-mm dishes
(905)
Multiplexed single-cell proteomics using SCoPE2
Nature Protocols
December 1, 2021
Aleksandra A. Petelski, Edward Emmott, Andrew Leduc, R. Gray Huffman, Harrison Specht, David H. Perlman, Nikolai Slavov
can be prepared by nPOP as described in ref. 23. We have successfully used Aria II, Aria III and
Sony
MA900
sorters. Other single-cell dispensers, such as Namocell, might also be usable, but we do not have direct
(906)
Antibody screening at reduced pH enables preferential selection of potently neutralizing antibodies targeting SARS‐CoV ‐2
AIChE Journal
December 1, 2021
Bharat Madan et al.
for the preparation and sorting of samples at their respective pH. Sorting was performed on a
SONY
MA900
cell sorter using associated software for sort data analysis. Sort gates were drawn for sorting as previously
(907)
Chromatin-based, in cis and in trans regulatory rewiring underpins distinct oncogenic transcriptomes in multiple myeloma
Nature Communications
December 1, 2021
Jaime Alvarez-Benayas et al.
selected 3 days post-transduction with puromycin (5 μg/ml), and 48 h later viable cells were sorted on
MA900 Multi-Application Cell Sorter
(
Sony Biotechnology
) and cultured in fresh DMEM/IMEM medium (Sigma, UK). Cells were grown for 10 days,
(908)
Repeated Social Defeat Exaggerates Fibrin-Rich Clot Formation by Enhancing Neutrophil Extracellular Trap Formation via Platelet–Neutrophil Interactions
Cells
November 28, 2021
Takeshi Sugimoto et al.
within the
neutrophil
population, as previously described [31].
Cell counting
was performed using a
Sony
MA900
(Sony Biotechnology Inc., Tokyo, Japan). Data were processed using FlowJo software (BD Biosciences). 2.11.
(909)
Peritransplant glucocorticoids redistribute donor T cells to the bone marrow and prevent relapse after haploidentical SCT
JCI insight
November 22, 2021
Inoue T, Koyama M, Kaida K, Ikegame K, Ensbey KS, Samson L, Takahashi S, Zhang P, Minnie SA, Maruyama S,
et al
.
cells (2–3
mice
/biological group) from the vehicle- and GC-treated recipients were acquired on a
Sony
MA900
cell sorter (purity at 93%–97%). Total RNA was extracted from each sorted
T cell
using a RNeasy micro
(910)
A Novel Isogenic Human Cell-Based System for MEN1 Syndrome Generated by CRISPR/Cas9 Genome Editing
International Journal of Molecular Sciences
November 8, 2021
Natalia Klementieva, Daria Goliusova, Julia Krupinova, Vladislav Yanvarev, Alexandra Panova, Natalia Mokrysheva, Sergey L. Kiselev
resuspended in mTeSR1 medium, and filtered through a 70 μm cell strainer. Next, cells were loaded into a
Sony
MA900
sorter (Sony Biotechnology Inc., Tokyo, Japan). Detection of the target population of OFP-positive cells
(911)
H3K9me selectively blocks transcription factor activity and ensures differentiated tissue integrity
Nature cell biology
November 1, 2021
Methot SP, Padeken J, Brancati G, Zeller P, Delaney CE, Gaidatzis D, Kohler H, van Oudenaarden A, Großhans H, Gasser SM.
low-bind tubes (Eppendorf) following a similar strategy using either a
BD
FACSAria
(Becton Dickinson) or
MA900
(
Sony
) cell sorter. For
RNA-seq
, approximately 25–50 × 103
muscle cells
or approximately 1 × 104 seam
(912)
HIV-1-Specific CD11c+ CD8+ T Cells Display Low PD-1 Expression and Strong Anti-HIV-1 Activity
Frontiers in Immunology
October 15, 2021
An-Liang Guo et al.
anti-CD8-BV510, and anti-CD11c-FITC antibodies, CD11c+ and CD11c- CD8+ T cells were sorted using a
MA900
Cell Sorter (
Sony Biotechnology
, Tokyo, Japan).
RNA Purification
and
Microarray Analysis
According
(913)
JAML promotes CD8 and γδ T cell antitumor immunity and is a novel target for cancer immunotherapy
Journal of Experimental Medicine
October 4, 2021
Joseph M. McGraw, Flavian Thelen, Eric N. Hampton, Nelson E. Bruno, Travis S. Young, Wendy L. Havran, Deborah A. Witherden
in R.
In vitro
expansion of CD8 and γδ
T cells
CD8 and γδ
T cell
splenocytes were sorted on a
Sony
MA900
chip cuvette sorter into RPMIc supplemented with 20% FCS. Sorted splenic CD8 T cells were expanded
in vitro
(914)
Dispensable roles of Gsdmd and Ripk3 in sustaining IL-1β production and chronic inflammation in Th17-mediated autoimmune arthritis
Scientific reports
September 21, 2021
Takeuchi Y, Ohara D, Watanabe H, Sakaguchi N, Sakaguchi S, Kondoh G, Morinobu A, Mimori T, Hirota K.
following monoclonal antibodies were used
for flow cytometry
(BD FACSCantoII) and
cell sorting
(
SONY
MA900
): anti-mouse CD4 (RM4-4), CD11b (M1/70), CD45.2 (104), Ly-6G (1A8), Podoplanin (8.1.1), IL-17A (TC11-18H10.1),
(915)
The adaptive immune system is a major driver of selection for tumor suppressor gene inactivation
Science (New York, N.Y.)
September 17, 2021
Martin TD, Patel RS, Cook DR, Choi MY, Patil A, Liang AC, Li MZ, Haigis KM, Elledge SJ.
infect CT26
mouse
cells. The truncated
mouse
CD19
marker was used to sort infected cells using a
Sony
MA900
cell sorter after
staining
with
PE anti-mouse CD19
(
Biolegend
, cat. #
152407
). In all experiments, CCL2
(916)
Adipose Tissue Macrophages Modulate Obesity-Associated β Cell Adaptations through Secreted miRNA-Containing Extracellular Vesicles
Cells
September 17, 2021
Gao H, Luo Z, Jin Z, Ji Y, Ying W.
101206
), and
F4/80
(
Biolegend
, Cat. No.
123116
).
CD45
+
CD11b
+
F4/80
+
macrophages
were purified using
SONY
MA900
flow cytometer
(SONY). In addition, cells were stained with
CD11c
(
Biolegend
, Cat. No.
117343
) and
CD206
(917)
Identification and Validation of T-cell Receptors Targeting
RAS
Hotspot Mutations in Human Cancers for Use in Cell-based Immunotherapy
Clinical Cancer Research
September 15, 2021
Noam Levin et al.
41BB+/OX40+ (both double- and single-positive cells), Live/CD3+, separated for CD4+ or CD8+ by SH800S/
MA900
instrument (
Sony
Biotechnology) or by
FACSAria
II (
BD Biosciences
). Construction of genes, peptides,
(918)
Improving Mobilization of Foreign DNA into Zymomonas mobilis Strain ZM4 by Removal of Multiple Restriction Systems
Applied and Environmental Microbiology
September 10, 2021
Piyush Behari Lal, Fritz Wells, Kevin S. Myers, Rajdeep Banerjee, Adam M. Guss, Patricia J. Kiley
GOTaq Flexi DNA polymerase
was from
Promega
. Primers were obtained from Integrated DNA Technologies (IDT). A
Sony
MA900
fluorescence
activated cell sorter (FACS) was used for sorting nonfluorescent cells from fluorescent
(919)
Chd1 protects genome integrity at promoters to sustain hypertranscription in embryonic stem cells
Nature communications
August 11, 2021
Bulut-Karslioglu A, Jin H, Kim YK, Cho B, Guzman-Ayala M, Williamson AJK, Hejna M, Stötzel M, Whetton AD, Song JS,
et al
.
SYTOX Blue (Invitrogen) was used to detect DNA content at
1:1000
dilution. Data was collected on a
Sony
MA900 Multi-Application Cell Sorter
, analyzed using FCS Express 7, and plotted using Prism 7. Bioinformatic analyses
ChIP-seq
, DSB-seq,
(920)
Functional Characterization of Hexacorallia Phagocytic Cells
Frontiers in Immunology
July 26, 2021
Grace A. Snyder, Shir Eliachar, Michael T. Connelly, Shani Talice, Uzi Hadad, Orly Gershoni-Yahalom, William E. Browne, Caroline V. Palmer, Benyamin Rosental, Nikki Traylor-Knowles
minutes at 250 x g and resuspended in 500 µL of FACS
staining
media and analyzed on a Sony SH800 (
Sony
MA900
for N. vectensis)
flow cytometer
fitted with a 100 µm nozzle. Gate selection for
cell sorting
included
Page
<<
<
46
47
48
49
50
>
>>
Reviews
Be the First to Write a Review!
MA900 Multi-Application Cell Sorter from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top