Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
Antibody Discovery
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Troubleshooting and Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
MA900 Multi-Application Cell Sorter
Supplier Images
Published Figures
MA900 Multi-Application Cell Sorter
MA900 Multi-Application Cell Sorter from Sony Corporation
Be the first to write a review!
Citations:
(989)
Figures:
(7)
Inquire
from
Sony Corporation for
MA900 Multi-Application Cell Sorter
Description
MA900 multi-application cell sorter features ease of use, support for up to 12 fluorescence parameters and 4-way sorting.
Product Specs
Citations
Reviews
Product Specs
Item
MA900 Multi-Application Cell Sorter
Company
Sony Corporation
Price
Inquire
Catalog Number
MA900
Lasers
2 lasers
Excitation
405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), 561 nm (36 mW)
Parameters
14 parameters / 12 fluorescence channels
Capacity
Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
Data Throughput
70,000 events/sec (max)
Dimensions
(WxDxH) 55 x 55 x 72 cm
Add to Compare List
Citations (989)
(41)
Gene expression adaptation of metastases to their host tissue
iScience
August 21, 2026
Luise Nagel, Marten Wenzel, Sascha Hoppe, Mohammad Karimpour, Patrick S. Plum, Abdossamad Hamoudi, Israt Jahan, Sarah Schmitt, Marek Franitza, Roger Wahba,
et al.
cells were isolated from mixed populations via
fluorescence-activated cell sorting
(FACS) using a
Sony
MA900
cell sorter with a 100 μm nozzle to ensure gentle handling of viable cells. RFP-positive CRC cells were
(42)
KLF4 in Smooth Muscle Cell–Derived Progenitor Cells Is Essential for Angiotensin II–Induced Cardiac Inflammation and Fibrosis
Arterioscler Thromb Vasc Biol
August 20, 2026
Sizhao Lu, Tysen Noble, Jake Elkins, Austin J. Jolly, Allison M. Dubner, Jeffrey G. Jacot, Brisa Peña Castellanos, Elizabeth J. Hardy, Raphael A. Nemenoff, Karen S. Moulton,
et al.
suspensions were stained with DAPI viability dye, and DAPI-negative cells were collected using FACS (
Sony
MA900
). The sorted viable cells were pelleted and resuspended in 1 mL fixation buffer (1× Fix & Perm Buffer
(43)
AI-enabled discovery and biochemical optimization of minibinders targeting cancer cell-surface proteins
Nat Commun
August 20, 2026
Bianca Broske, Benjamin A. McEnroe, Sophie C. Frechen, Tim N. Kempchen, Caroline I. Fandrey, Elisabeth Tan, Dominic Ferber, Michelle C. R. Yong, Marie Kleinert, Julia M. Messmer,
et al.
immediately after
staining
for distinct APC-signal using the
fluorescence
-activated cell sorter
Sony
MA900
. Sorted cells were lysed in direct lysis buffer (1 mM CaCl2, 3 mM MgCl2, 1 mM EDTA, 1% (v/v) Triton
(44)
Hypoxia-activated scleraxis a mediates epicardial progenitor differentiation into a unique cardiac perivascular cell type
Nature Communications
August 20, 2026
Björn Perder, Yu Xia, Jun Yao, Ignace Van der Wee, Miaoyan Qiu, Alvin Gea Chen Yao, Muhammad Naeem, Paul Zumbo, Avi Yakubov, Stephanie L. Tsai,
et al.
spun down and re-suspended in DMEM plus 10% fetal bovine serum (FBS) medium and sorted using a
Sony
MA900
sorter for EGFP+ cells (uninjured) and EGFP+mScarlet+ (3 dpa). Nuclei preparation and CUT&Tag library
(45)
Multiscale integration of tissue and chromatin context converts cell heterogeneity into stable intestinal patterning
Cell
August 20, 2026
Cornelia Schwayer, Silvia Barbiero, David B. Brückner, Koen C. Oost, Clara Baader, Nicole A. Repina, Jinse Kim, Oscar E. Diaz, Isa Uccelli, Laura Capolupo,
et al.
a 30μm cell strainer. Single cells were sorted using a Becton Dickinson Influx cell sorter or
SONY
,
MA900
cell sorter equipped with a 100μm nozzle. Live single cells were gated based on DRAQ7
staining
, size,
(46)
NAP1 switches from an activator to a limiter of interferon induction by trapping TBK1 in condensates
Nature Communications
August 19, 2026
Damien Glon, Quentin Riller, Lucía Álvarez, Louise Gioja, Frédéric Rivière, Benjamin Léonardon, Zackie Aktary, Ariane Guillemot, Laïla Sago, Olivier Pellé,
et al.
electroporation
, cells were allowed to recover for 48 hours before single-
cell sorting
was performed using a
Sony
MA900
cell sorter. Single cells were plated into 96-well plates containing RPMI-1640 medium supplemented with
(47)
Human iPSC-derived bone marrow organoids with integrated hematopoietic and T cell-supportive niches
Stem Cell Research & Therapy
August 19, 2026
Jiyoung Lee, Tomoyuki Kawasaki, Lilika Tabata, Junlong Chen, Toru Uchiyama, Satoshi Yamazaki, Akihiro Umezawa, Hidenori Akutsu
method.
Flow cytometry analysis
Flow cytometry
was performed using a
FACSAria
II (
BD Biosciences
), SH800, or
MA900
flow cytometer
(
Sony
). For analysis of iBMOs, day-14
organoids
were dissociated using collagenase I
(48)
Self-sufficient killing of malignant tumors by an engineered cancer-selective gene circuit
Cell Reports Medicine
August 18, 2026
Qi Liu, Qiqi Xiong, Guanglei Xie, Qidi Chen, Shujie Yang, Yuhang Wu, Liuqi Zhao, Ting Gao, Xinyuan Qiu, Jian Jiang,
et al.
lentiviral particles created with pQL80 as transfer plasmid. Following
flow cytometric
sorting using the
MA900 Multi-Application Cell Sorter
(
Sony Biotechnology
; San Jose, CA), the cell population showing strongest red
fluorescence
were harvested.
(49)
Juvenile influenza can impair myelin development and adult behavior through chemokine signaling in mice
bioRxiv
August 17, 2026
Karen Malacon, Kiarash Shamardani, Sophia Artandi, Lijun Ni, Natalia K. Zernicka-Glover, Abigail Rogers, Belgin Yalçın, Enrique Herrera Castañeda, Theresa Pham, Akiko Iwasaki,
et al.
transferred to
fluorescence-activated cell sorting
(FACS) tubes. Nuclei were then sorted using a
Sony
MA900
sorter with a 70 μm chip. A standard gating strategy was applied to all samples, first gating nuclei
(50)
MERTK inhibition cooperates with immunomodulatory cyclophosphamide to induce CXCL9+ monocyte-macrophage programming and durable antitumor immunity in triple negative breast cancer
Cancer Immunol Res
August 17, 2026
Alex J. Smith, Zachary Schrank, Nan Guan, Diego A. Pedroza, Sebastian J. Calderon, Xueying Yuan, Na Zhao, Zoe Gabriel, Yang Gao, Charlotte H. Rivas,
et al.
collection buffer (PBS + 20%FBS) with
DAPI
. Minimally, 150,000 cells were sorted for
DAPI
-
CD45
+ on a
Sony
MA900
in the
Cytometry
and
Cell Sorting
Core at Baylor College of Medicine. After sorting, cells were spun,
(51)
Identifying phenotype-genotype-function coupling in 3D organoid imaging using Shape, Appearance and Motion Phenotype Observation Tool (SPOT)
Nat Commun
August 17, 2026
Felix Y. Zhou, Brittany-Amber Jacobs, Adam Norton-Steele, Xiaoyue Han, Linna Zhou, Thomas M. Carroll, Carlos Ruiz Puig, Joseph Chadwick, Xiao Qin, Richard Lisle,
et al.
days. To generate a homogenous population of
organoids
positive for the fluorescent protein of interest, a
MA900 Multi-Application Cell Sorter
(
Sony Biotechnology
) was used.
Fluorescence
was detected within 24 h of lentiviral transduction. To
(52)
Hypoxia differentially affects coronary vessel formation during heart development
Cardiovascular Research
August 14, 2026
Sophie Payne, Susann Bruche, Dorota Szumska, Lucija Fleisinger, Alice Neal, Mark D Preston, Sarah De Val
cells were also prepared as controls for setting up the FACS machine. Cells were sorted using a
Sony
MA900
FACS Sorter, with gating set up first using an FSC-A vs. BSC-A plot to exclude cell debris, then an
(53)
Lysosomal dysfunction drives a transcriptional and epigenetic signature characteristic of disease-associated microglia in neurodegenerative diseases
Immunity
August 11, 2026
Christopher D. Balak, Johannes C.M. Schlachetzki, Addison J. Lana, Elizabeth West, Christine Hong, Jordan DuGal, Yi Zhou, Benjamin Li, Nathanael J. Spann, Payam Saisan,
et al.
Cells were then washed and filtered through a 40 μm cell strainer. Sorting was performed on a
Sony
MA900
or Beckman Coulter MoFlo Astrios EQ cell sorter.
Microglia
were defined as events that were DAPI negative,
(54)
Cell surface ADGRG1 and CD86 expression identifies antitumor CD4+ T cells in human cancer
Proc Natl Acad Sci U S A
August 11, 2026
Kyle J. Hitscherich, Aaron J. Dinerman, Abraham A. Hakim, Victoria Dulemba, Sivasish Sindiri, Billel Gasmi, Alakesh Bera, Jared J. Gartner, Todd D. Prickett, Zhiya Yu,
et al.
or CITE-seq as indicated in individual experiments. Cells were isolated via
flow cytometry
via
Sony
MA900 Multi-Application Cell Sorter
(Sony Biotechnology, San Jose, CA). Mean fluorescent intensity (MFI) gates for each population were
(55)
Nuclear compartmentalization at the G1/S transition plays a key role in DNA replication control
Nat Commun
August 10, 2026
Asami Oji, Kosuke Yusa, Izumi Noda, Takako Ichinose, Yoshiko Kondo, Ichiro Hiratani
incubated at 37 °C. After 10 min, cells were filtered through a cell strainer and sorted using a
Sony
MA900
cell sorter (purity mode). After sorting ~3 × 106 cells per FACS gate in three independent experiments,
(56)
Uncovering the signaling networks of disseminated glioblastoma cells in vivo with INSIGHT
Nature Communications
August 8, 2026
Ryuhjin Ahn, Alicia D. D’Souza, Lawrence Long, Yufei Cui, Jennifer Gantchev, Gerard Baquer, Danielle Burgenske, Katrina K. Bakken, Lauren L. Ott, Brett L. Carlson,
et al.
from normal cells for the samples subjected to
mass spectrometry
. For all sorting experiments,
Sony
MA900
(70 µm nozzle) was used to sort cells into 5 ml tubes. Cells were stained with
anti-O4
antibody-APC
(57)
Genomic repeats for single-cell molecular recording
bioRxiv
August 7, 2026
Rachel K. Dveirin, Jessica D. Lin, Preeti Vyas, Jiaxi Lu, Yuqing Yan, Jennifer J. Lee, Xinzhong Dong, Sujatha Kannan, Ben Langmead, Sashank K. Reddy,
et al.
mCherry+ cells and
sequencing
of RGR loci All
flow cytometry
experiments were performed using a
Sony
MA900
system with 100-uM sorting chips (Sony). Prior to each sorting session, the instrument was calibrated
(58)
Localized immunomodulation with cytokine-producing cells to mitigate foreign body responses in rodents and a nonhuman primate
Sci Adv
August 7, 2026
Boram Kim, Dilrasbonu Vohidova, Amanda Nash, Yuen San Chan, Samantha Fleury, Shravani Deo, Danna Murungi, Peter D. Rios, Ira Joshi, Hafsa Nasir,
et al.
were resuspended in
cell staining
buffer and run through a 40-μm filter before acquisition on a
Sony
MA900
. Single-color,
fluorescence
minus one (FMO) controls, as well as a negative unstained control, were
(59)
Regression-Associated Macrophages Recruit Natural Killer Cells That Constrain Targeted Therapy Resistance
Cancer Res
August 5, 2026
Chia-Hsin Hsu, Jingyi Chen, Leanne R. Donahue, Keng-Jung Lee, Yu-Wei Chang, Jianping Lin, Danielle Kacaj, Richard M. White, Robert S. Weiss, Zhong-Yin Zhang,
et al.
CD63+ MHC II+
macrophages
and the corresponding remainder
macrophage
population were sorted using
Sony
MA900
.
NK cell
isolation and culture
NK cells
were isolated by negative selection from the spleens of naive
(60)
Human-specific SRGAP2 paralogs synchronize neotenic microglial maturation and synaptic development
Neuron
August 5, 2026
Carlos Diaz-Salazar, JaeYeon Kim, Marine Krzisch, Juyoun Yoo, Patricia R. Nano, Aparna Bhaduri, Rudolf Jaenisch, Mercedes Paredes, Franck Polleux
sorted directly into TRIzol (
Thermo Fisher Scientific
) as
CD11b
+, CD45low,
CX3CR1
+ cells on a
Sony
MA900
(SONY) sorter with a 100 μm
microfluidic
chip. TRIzol containing the cell lysates was mixed with chloroform
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
MA900 Multi-Application Cell Sorter from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews