Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
MA900 Multi-Application Cell Sorter
Supplier Images
Published Figures
MA900 Multi-Application Cell Sorter
MA900 Multi-Application Cell Sorter from Sony Corporation
Be the first to write a review!
Citations:
(918)
Figures:
(7)
Inquire
from
Sony Corporation for
MA900 Multi-Application Cell Sorter
Description
MA900 multi-application cell sorter features ease of use, support for up to 12 fluorescence parameters and 4-way sorting.
Product Specs
Citations
Reviews
Product Specs
Item
MA900 Multi-Application Cell Sorter
Company
Sony Corporation
Price
Inquire
Catalog Number
MA900
Lasers
2 lasers
Excitation
405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), 561 nm (36 mW)
Parameters
14 parameters / 12 fluorescence channels
Capacity
Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
Data Throughput
70,000 events/sec (max)
Dimensions
(WxDxH) 55 x 55 x 72 cm
Add to Compare List
Citations (918)
(101)
Dual role of Ninjurin-1 in myeloid cell adhesion and inflammation in relapse-remitting EAE
Front Immunol
April 15, 2026
Coleen Thompson, Alex Annett, Anastasia Alkhimovitch, Kashish Singh Parihar, Igal Ifergan
CD45+CD11b+B220-CD3-Ly6G-Ninjurin-1+ (Ninjurin-1+) or CD45+CD11b+B220-CD3-Ly6G-Ninjurin-1- (Ninjurin-1-) using a
MA900
(
Sony
). 2.9
Quantitative PCR
After
cell sorting
, both populations obtained from
cell sorting
(Ninjurin-1+
(102)
Medullary cavity expansion is mediated by distinct cell populations during fetal bone development
Nature Communications
April 14, 2026
Eriko Sumiya, Kohei Saeki, Kenta Nakano, Chie Kikutake, Noriko Kurisaki, Natsuko Nakaima, Mami Kurumata-Shigeto, Yumiko Kitada, Yuka Morioka, Yasuhiro Go,
et al.
(
TONBO
,
75-4031-U100
).
Flow cytometric analysis
and
cell sorting
were performed with
SA3800
, SH800,
MA900
(
Sony
Imaging Products & Solutions) or FACS Melody (BD Biosciences). Data was analyzed using FlowJo
(103)
Lipid metabolism transcriptomic signature of defective erythropoiesis in Diamond Blackfan anemia syndrome∗
Blood Advances
April 14, 2026
Kaiwen Deng, Yu Wang, Joseph C. Min, Xiaofang Liu, Hiroki Ueharu, Greggory Myers, Lei Yu, Susan B Hammoud, Adham Adam, Rilie Saba,
et al.
CD71+/Ter119− cells were sorted to obtain early
erythroid progenitor cells
(BD FACS ARIA III or
Sony
MA900
Cell Sorter). Total RNA was extracted using RNeasy Micro Kit (
Qiagen
; catalog no.
74004
) and used for
(104)
Mucosal tissue NK cells tune their function between optimal anti-pathogen activity and tissue protection
bioRxiv
April 13, 2026
Sarah C. Vick, Eva Domenjo-Vila, Marie Frutoso, Raisa A. Glabman, Lakshmi S. Warrier, Sean M. Hughes, Anna C. Kirby, Michael F. Fialkow, Florian Hladik, Martin Prlic,
et al.
and each condition was represented by 4 biological replicates.
Cell sorting
was performed on a
Sony
MA900
(Sony) using a 100-μm sorting chip with 90% sort efficiency and 90–95% purity. Cells were sorted directly
(105)
Synaptic proteins that aggregate and degrade slower with aging accumulate in microglia
bioRxiv
April 12, 2026
Ian H. Guldner, Viktoria P. Wagner, Patricia Moran-Losada, Sophia M. Shi, Kelly Chen, Barbara T Meese, Hamilton Oh, Yann Le Le Guen, Nannan Lu, Pui Shuen Wong,
et al.
Fluorescence Activated Cell Sorting
(FACS).
CD11b
+/brain
macrophages
were sorted by gating on
CD11b
+, Calcein-AM+ singlets on a
Sony
MA900
cell sorter (Sony Biotechnology, Inc). Three biological replicates-worth of brain
macrophages
were pooled
(106)
EXOSC3 S1-domain variants implicated in PCH1b alter RNA exosome cap subunit abundance and thermal stability disrupting rRNA processing and targeting of AU-rich mRNA
bioRxiv
April 12, 2026
Avery M. Runnebohm, H.R. Sagara Wijeratne, Monica P. Barron, Whitney R. Smith-Kinnaman, James D. Rooney, Sarah A. Peck Justice, Lauryn A. Cureton, Annalise Holland, Homa Ghalei, Stephane Pelletier,
et al.
samples were passed through a 40 μm cell strainer to remove aggregates. FACS was performed using a
Sony
MA900
cell sorter equipped with 488 nm and 561 nm laser lines and corresponding emission filters (FL2 585/30
(107)
Structure-specific Mini-Prion Model for Alzheimer’s Disease Tau Fibrils
bioRxiv
April 12, 2026
Vishnu Vijayan, Gregory E. Merz, Karen Tsay, Andrew P. Longhini, Samuel Lobo, Athena Quddus, Kristi Lynn S. Nakagawa, Michael P. Vigers, Arthur A. Melo, Eric Tse,
et al.
in 500 μg/mL geneticin (G418), followed by
fluorescence-activated cell sorting
(FACS) using a
Sony
MA900
sorter to isolate populations co-expressing red (mRuby3) and green (mClover3)
fluorescence
. Cells were
(108)
Pluripotent Stem Cell Plasticity is Sculpted by a Slit-Independent Robo Pathway in a Regenerative Animal
bioRxiv
April 12, 2026
Kuang-Tse Wang, Yu-Chia Chen, Fu-Yu Tsai, Catherine P Judy, Carolyn E Adler
temperature for 20 minutes. Live cells were identified by Calcein-AM
staining
and sorted using a
Sony
MA900
Cell Sorter. A total of 100,000 cells were sorted and diluted to 1000 cells/μL for subsequent 10X library
(109)
Phenotypic screening for small molecules that lower PrP in cultured cells
bioRxiv
April 9, 2026
Jeannine A Frei, Andrew G Reidenbach, Leo Mh Xu, Raja Mohan Gopalakrishnan, Dominick Casalana, Daniel A Sprague, Mark-Anthony Bray, Amy Q. Wang, Vanessa Laversenne, Brian Erickson,
et al.
were analyzed on a
Cytoflex S flow cytometer
(
Beckman
Coultier).
HEK293 cells
were analyzed on a
Sony
MA900
cell sorter (Sony). Nucleated cells were distinguished from debris and dead cells based on forward scatter-A/side
(110)
A basophil-specific GPCR mediates the immune response to helminth infection
bioRxiv
April 8, 2026
Aleksander Geske, Rachel Pan, Celeste Flores, Taylor Follansbee, Nathachit Limjunyawong, Xintong Dong, Xinzhong Dong
prior. Dead cells were stained with SYTOX Blue (Thermo Fisher).
Cell sorting
was performed on the
Sony
MA900
cell sorter (Sony Biotechnology) with a 100 μm nozzle.
Basophils
were gated as CD45+c-kit−FceRI+CD200R3+Cd49b+.
RNA sequencing
(111)
Activation of ERBB4 Pathway Inhibits Pathological Transdifferentiation of Lung Epithelial Progenitors into CD66c + Basal Cells in Severe Lung Injury
Advanced Science
April 7, 2026
Kaijun Lin, Xinran Deng, Haonan Wang, Yamei Jiang, Jian Sun, Hailin Ding, Ming Ye, Xiaoting Wang, Yu Wang, Li Yuan,
et al.
eBioscience). Following
filtration
through a 40 µm strainer, single cells were analyzed or sorted on an
MA900
flow cytometer
(
Sony
, Japan) following exclusion of doublets and dead cells. FACS‐sorted cells were
(112)
Charged molecular glue discovery enabled by targeted degron display
Nature Chemical Biology
April 6, 2026
Zhe Zhuang, Woong Sub Byun, Jakub Chrustowicz, Zuzanna Kozicka, Veronica L. Li, Dinah M. Abeja, Katherine A. Donovan, Sara Sepic, Inchul You, Mikołaj Słabicki,
et al.
and bottom 5%) on the basis of the mean
fluorescence
intensity ratio of
BRD4
–eGFP to mCherry on an
MA900
Cell Sorter (
Sony
). Sorted cells were collected by
centrifugation
, subjected to direct lysis and amplified
(113)
Nanobody-based bioPROTAC for viral protein degradation provides an antiviral strategy for porcine arterivirus
Journal of Nanobiotechnology
April 5, 2026
Shibo Su, Mingxia Sun, Haiwei Wang, Yan-Dong Tang, Jin Chen, Xinqi Shi, Shuang Cai, Hanrong Zhou, Wei Yang, Ning Zhang,
et al.
cells expressing mCherry were sorted into 96-well plates at a density of one cell per well via a
SONY
-
MA900
Flow Cell Sorter. The sorted monoclonal cells were expanded for culture and monitored by
fluorescence microscopy
(114)
Functional sQTLs regulating PTK2B exon 31 splicing uncover an RNA-dependent modulation of its kinase activity and cellular phenotype
Cell Communication and Signaling
April 2, 2026
Masahide Kato, Ayaka Isazawa, Ai Ohki, Akari Fujita, Makoto Araki, Motoaki Yanaizu, Yoshihiro Kino
puromycin. After selection with puromycin, single cells were seeded into 96-well plates using a cell sorter
MA900
(
SONY
, Tokyo, Japan), and multiple stable
clones
were established. Induction of HA expression after
(115)
Regulatory T-cell sensing of extracellular ATP via P2RX7 promotes their accumulation and suppression and drives lung tumor growth
Cancer Immunol Res
April 2, 2026
Igor Santiago-Carvalho, Ronaldo Francisco, Bruna de Gois Macedo, Caio Loureiro Salgado, Carly R. Stoll, Samantha Shao, Angad Beniwal, Tina Kwok, Alma Banuelos, Marcos Pinheiro Cione,
et al.
(
Foxp3
/
GFP
+
CD25
+CD4+ T cells) were sorted from the lung of WT and Treg-specific P2RX7-KO
mice
at day 30 p.i. using a
MA900 Multi-Application Cell Sorter
(
Sony
Biotechnology). Sorted lung Tregs were plated with pre-activated WT CD4+ or CD8+ T cells isolated
(116)
Deletion of SPI1 in microglia exacerbates amyloid pathology by impairing microglial response in Alzheimer's disease models
Neuron
April 1, 2026
Kim B, Tate MD, Karahan H, Wijeratne HRS, Sharify AD, Wang SS, Kim JR, Al-Amin MM, Hartigan K, Chung S,
et al
.
analysis. The frequency of viable MeX04+
CD11b
+CD45high microglia was measured by
flow cytometry
using an
MA900
cell sorter (
Sony
Biotechnology) and analyzed using FlowJo™ (v10.9.0, BD Biosciences). The median
fluorescence
(117)
Efficient Generation of Functional TCRαβ + Cytotoxic T Cells from hiPSCs via Small-Molecule Modulation
bioRxiv
April 1, 2026
Caroline Kubaczka, Netra Kambli, Roland Windisch, Kelly Yu, Yunliang Zhao, Sharon Wu, Katie Frenis, Morgan T. Walcheck, Marcelo Falchetti, Mohamad Najia,
et al.
buffer containing viability dye (PI, DAPI or Sytox Blue). Sample acquisition was performed on a
SONY
MA900
,
LSRFortessa
(
BD
) or Cytek Aurora and analyzed using FlowJo v10.10.0. For
zebrafish
experiments, pools
(118)
The landscape of regulatory element evolution in a C4 perennial grass
BMC Genomics
March 30, 2026
Taslima Haque, Govinal Badiger Bhaskara, Robert J. Schmitz, Thomas E. Juenger
extract was stained with 4,6-diamidino-2-phenylindole (DAPI) and loaded into a
flow cytometer
(
Sony
MA900
) to sort nuclei. Sorted nuclei were further washed and treated with 2 uL Tn5 transposase in 40 uL tagmentation
(119)
Epigenetic control of PDX1 and NGN3 by a computationally designed PRC2 inhibitor enforces pancreatic endocrine differentiation from pluripotent stem cells
Research Square
March 27, 2026
Vincenzo Cirulli, Laura Crisa, shiri levy, Daniel Bomsztyk, Stephanie Bomsztyk, Stephanie Battle, Cecilia Lopez-Martinez, Cecilia Lpez-Martinez, Patrick McGrath, Julie Mathieu,
et al.
transfected
hPSC pool was clonally expanded following single-cell deposition into 96-well plates using a
Sony
MA900
cell sorter. Clonally expanded lines were screened for puromycin
sensitivity
to confirm excision of
(120)
Pathogenic GM-CSF drives functional diversification of inflammatory macrophages in autoimmune arthritis
Sci Adv
March 27, 2026
Hiroki Mukoyama, Yusuke Takeuchi, Daiya Ohara, Yoonha Lee, Hitomi Watanabe, Hiroki Kato, Gen Kondoh, Akio Morinobu, Keiji Hirota
S (Beckman Coulter) was used
for flow cytometry
analysis, and
FACSAria
III (
BD Biosciences
) and an
MA900
cell sorter (
Sony
) were used for
cell sorting
.
Flow cytometry
data were analyzed using the FlowJo software
Page
<<
<
6
7
8
9
10
>
>>
Reviews
Be the First to Write a Review!
MA900 Multi-Application Cell Sorter from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top