Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
Antibody Discovery
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
MA900 Multi-Application Cell Sorter
Supplier Images
Published Figures
MA900 Multi-Application Cell Sorter
MA900 Multi-Application Cell Sorter from Sony Corporation
Be the first to write a review!
Citations:
(989)
Figures:
(7)
Inquire
from
Sony Corporation for
MA900 Multi-Application Cell Sorter
Description
MA900 multi-application cell sorter features ease of use, support for up to 12 fluorescence parameters and 4-way sorting.
Product Specs
Citations
Reviews
Product Specs
Item
MA900 Multi-Application Cell Sorter
Company
Sony Corporation
Price
Inquire
Catalog Number
MA900
Lasers
2 lasers
Excitation
405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), 561 nm (36 mW)
Parameters
14 parameters / 12 fluorescence channels
Capacity
Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
Data Throughput
70,000 events/sec (max)
Dimensions
(WxDxH) 55 x 55 x 72 cm
Add to Compare List
Citations (989)
(541)
Candida albicans-Derived β-Glucan as a Novel Modulator of Tumor Microenvironment: Targeting Macrophage Polarization and Inducing Ferroptosis in Lung Cancer
Journal of Inflammation Research
December 6, 2024
Xiang He, Qin Ran, Xiaolan Li, Anying Xiong, Lei Zhang, Manling Jiang, Lingling Bai, Dan Peng, Junyi Wang, Baoqing Sun,
et al.
processes were performed according to recommended protocols. The stained cells were detected by
SONY
MA900
flow cytometer
(SONY, Tokyo, Japan). FACS data analysis was performed using FLOWJOTM Software.
Quantitative Real-Time PCR
(542)
Candida albicans-Derived β-Glucan as a Novel Modulator of Tumor Microenvironment: Targeting Macrophage Polarization and Inducing Ferroptosis in Lung Cancer
J Inflamm Res
December 6, 2024
Xiang He, Qin Ran, Xiaolan Li, Anying Xiong, Lei Zhang, Manling Jiang, Lingling Bai, Dan Peng, Junyi Wang, Baoqing Sun,
et al.
processes were performed according to recommended protocols. The stained cells were detected by
SONY
MA900
flow cytometer
(SONY, Tokyo, Japan). FACS data analysis was performed using FLOWJOTM Software.
Quantitative Real-Time PCR
(543)
Immune responses in checkpoint myocarditis across heart, blood and tumour
Nature
December 5, 2024
Steven M. Blum, Daniel A. Zlotoff, Neal P. Smith, Isabela J. Kernin, Swetha Ramesh, Leyre Zubiri, Joshua Caplin, Nandini Samanta, Sidney Martin, Mike Wang,
et al.
cells were resuspended in sort buffer containing
DAPI
.
Flow cytometric
sorting was performed on a
Sony
MA900
Cell Sorter (Cell Sorter Software v 3.3.0) to collect live, singlet,
CD235a
- cells (Extended Data Fig
(544)
Cross-species single-cell RNA-seq analysis reveals disparate and conserved cardiac and extracardiac inflammatory responses upon heart injury
Communications biology
December 3, 2024
Cortada E, Yao J, Xia Y, Dündar F, Zumbo P, Yang B, Rubio-Navarro A, Perder B, Qiu M, Pettinato AM,
et al
.
0.05% sodium azide in PBS) at 4 °C with fluorescent antibodies and analyzed and FAC-sorted on a
Sony
MA900
cell sorter. The following antibodies were used for WBC analysis:
Anti-CD16/32
(
Biolegend
cat.
101302
,
(545)
Thyroid hormone receptor beta (THRβ1) is the major regulator of T3 action in human iPSC-derived hepatocytes
Molecular metabolism
December 1, 2024
Soares De Oliveira L, Kaserman JE, Van Der Spek AH, Lee NJ, Undeutsch HJ, Werder RB, Wilson AA, Hollenberg AN.
(
ThermoFisher Scientific
), as per manufacturer's instructions.
Staining
quantification was measured using
MA900 Multi-Application Cell Sorter
(
Sony
). Data analysis was performed using FlowJo software (Becton, Dickinson & Company). For all
flow cytometry analysis
(546)
An organotypic atlas of human vascular cells
Nature Medicine
December 1, 2024
Sam N. Barnett, Ana-Maria Cujba, Lu Yang, Ana Raquel Maceiras, Shuang Li, Veronika R. Kedlian, J. Patrick Pett, Krzysztof Polanski, Antonio M. A. Miranda, Chuan Xu,
et al.
antibodies and DAPI for 30 min. After
staining
, cells were washed and analyzed using Sony SH800 or
Sony
MA900
sorters (Cell Sorter Software version 3.1.1) with a 130-μm nozzle. Two cell fractions—one, positive
(547)
Directed-evolution mutations enhance DNA-binding affinity and protein stability of the adenine base editor ABE8e
Cellular and Molecular Life Sciences
December 1, 2024
Haixia Zhu, Lei Wang, Ying Wang, Xinyi Jiang, Qin Qin, Menghua Song, Qiang Huang
2.7 mM KCl, 10.0 mM Na2HPO4, 1.8 mM KH2PO4, pH 7.4).
Flow cytometry analysis
was carried out using a
MA900 Multi-Application Cell Sorter
(
Sony
). Genomic DNA was extracted using the TIANamp Genomic DNA Kit (TIANGEN) according to the manufacturer’s
(548)
IRF2BP2 binds to a conserved RxSVI motif of protein partners and regulates megakaryocytic differentiation
Nature Communications
November 30, 2024
Guanchao Wang, Tiantian Lu, Lei Zhang, Jianping Ding
(
BD Biosciences
), collecting a minimum of 10,000 events per sample. FACS sorting was performed with a
Sony
MA900
instrument (Sony) using the GFP tag. Morphological analysis Cells were collected on the third day
(549)
Hypoimmunogenic CD19 CAR-NK cells derived from embryonic stem cells suppress the progression of human B-cell malignancies in xenograft animals
Frontiers in Immunology
November 27, 2024
Qi Zhang, Chengxiang Xia, Qitong Weng, Leqiang Zhang, Yao Wang, Yanhong Liu, Xiujuan Zheng, Yunqing Lin, Yi Chen, Yiyuan Shen,
et al.
antibody (
clone
: W6/32,
Biolegend
,
311404
) on ice for 15-30 min. HLA-ABC negative ESCs were sorted by
Sony
MA900
Sorter. 2.3
HLA-E
and CD19 CAR transduction in B2M KO-ESC The fragment encoding a single chain trimer
(550)
Immune System-Related Plasma Pathogenic Extracellular Vesicle Subpopulations Predict Osteoarthritis Progression
International Journal of Molecular Sciences
November 21, 2024
Xin Zhang, Sisi Ma, Syeda Iffat Naz, Erik J. Soderblom, Vaibhav Jain, Constantin Aliferis, Virginia Byers Kraus
tested biomarkers, as defined by the percentages of EVs carrying each biomarker, were measured using a
MA900
flow cytometer
with 4-way sorting function (
Sony Biotechnology
, San Jose, CA, USA) and analyzed using
(551)
Functional genomics screens reveal a role for TBC1D24 and SV2B in antibody-dependent enhancement of dengue virus infection
Journal of Virology
November 19, 2024
Laura Belmont, Maya Contreras, Catiana H. Cartwright-Acar, Caleb D. Marceau, Aditi Agrawal, Lisa M. Levoir, Jay Lubow, Leslie Goo
330105
,
Biolegend
), and cell populations highly expressing both DCSIGN and BFP were bulk sorted (
Sony
MA900
). C6/36 cells were maintained at 30°C in 5% CO2; all other cell lines were maintained at 37°C in 5%
(552)
Eosinophils mitigate intestinal fibrosis while promoting inflammation in a chronic DSS colitis model and co-culture model with fibroblasts
Scientific reports
November 7, 2024
Jacobs I, Deleu S, Ke BJ, Cremer J, Dilissen E, De Hertogh G, Martens T, Vanden Berghe P, Matteoli G, Vermeire S,
et al
.
suspension was dissolved at a maximum of 5.106 cells per mL.
Eosinophils
were furthermore sorted on a
Sony
MA900
based on a high side scatter and high autofluorescence profile (purity > 95%; supplementary Fig. 5).
In vitro
(553)
A novel method for the preparation of reproducible, stable, and non-infectious quality control materials for Chlamydia trachomatis nucleic acid detection
Microbiology Spectrum
November 5, 2024
Jing Li, Kuo Zhang, Yanxi Han, Rongxue Peng, Lin Li, Jinming Li, Guigao Lin
at the Peking Union Medical College State Key Laboratory of Medical Molecular Biology using a
Sony
MA900
cell sorter (Sony Biotechnology, San Jose, CA, USA). The sorted cells were cultured in DMEM supplemented
(554)
Comparison of seven CD19 CAR designs in engineering NK cells for enhancing anti‐tumour activity
Cell Proliferation
November 1, 2024
Yao Wang, Jianhuan Li, Zhiqian Wang, Yanhong Liu, Tongjie Wang, Mengyun Zhang, Chengxiang Xia, Fan Zhang, Dehao Huang, Leqiang Zhang,
et al.
CD56 and anti‐FMC63 scFv were used to sort transduced UCB‐
NK cells
for CD56+CAR+
NK cells
using
Sony
MA900
(SONY). Data were analysed with FlowJo software (FlowJo_v10.8.1). To assess the expression of NK receptor
(555)
Shear Stress Induces a Time-Dependent Inflammatory Response in Human Monocyte-Derived Macrophages
Annals of Biomedical Engineering
November 1, 2024
Elysa Jui, Griffin Kingsley, Hong Kim T. Phan, Kavya L. Singampalli, Ravi K. Birla, Jennifer P. Connell, Sundeep G. Keswani, K. Jane Grande-Allen
transferred to 5 mL
flow cytometry
tubes.
Flow cytometry
data for all markers was acquired using the
Sony
MA900 multi-application cell sorter
(Sony Biotechnology Inc) and was analyzed using FlowJo. 2.4 Viability
staining
and morphology quantification Cell
(556)
Suppression of non-muscle myosin II boosts T cell cytotoxicity against tumors
Science advances
November 1, 2024
Yang Y, Wen D, Lin F, Song X, Pang R, Sun W, Yu D, Zhang Z, Yu T, Kong J,
et al
.
(PBS), these cells were filtered through a 40-μm strainer to remove clumps and then sorted on a
Sony
MA900
automatic flow separator.
Flow cytometry
For cell apoptosis
staining
, activated CTLs pretreated with
(557)
Intra-lymph node crosslinking of antigen-bearing polymers enhances humoral immunity and dendritic cell activation
Bioengineering & translational medicine
November 1, 2024
Euliano EM, Agrawal A, Yu MH, Graf TP, Henrich EM, Kunkel AA, Hsu CC, Baryakova T, McHugh KJ.
flow cytometry
;
spleen
samples were measured using a
Sony
SA3800
Cytometer and LN samples using a
Sony
MA900
Cell Sorter (Sony Biotechnology, San Jose, CA). 2.10 Statistics All group comparisons were calculated
(558)
Genome-wide screen of Mycobacterium tuberculosis-infected macrophages revealed GID/CTLH complex-mediated modulation of bacterial growth
Nature Communications
October 29, 2024
Nelson V. Simwela, Luana Johnston, Paulina Pavinski Bitar, Eleni Jaecklein, Craig Altier, Christopher M. Sassetti, David G. Russell
paraformaldehyde (PFA) for >1 hour before FACS of cells in the live gate. FACS was carried out on a
Sony
MA900
sorter, and a minimum of 10 million cells were sorted per replicate to achieve a >150× library coverage. DNA
(559)
JK-1, a useful erythroleukemic cell line model to study a controlled erythroid differentiation from progenitors to terminal erythropoiesis
Scientific Reports
October 29, 2024
Sylvain Metral, Sandrine Genetet, Benoît Gamain, Isabelle Mouro-Chanteloup
tested by MGG
staining
or
flow cytometry analysis
.
Cell sorting
processes were carried out using a
SONY
MA900
sorter at speeds of 3000–4000 events per second with a 100 μm nozzle and purity mode.
Western blot analysis
(560)
Caspase-1 in Cx3cr1-expressing cells drives an IL-18-dependent T cell response that promotes parasite control during acute Toxoplasma gondii infection
PLOS Pathogens
October 24, 2024
Isaac W. Babcock, Lydia A. Sibley, Sydney A. Labuzan, Maureen N. Cowan, Ish Sethi, Seblework Alemu, Abigail G. Kelly, Michael A. Kovacs, John R. Lukens, Tajie H. Harris
were pre-gated on live, and Zsgreen+ then sorted 4 ways based on F480 and
Ly6C
expression using a
Sony
MA900
and a 100 μM chip at the UVA
flow cytometry
core facility. Cells were collected in Trizol.
ELISA
and
Page
<<
<
26
27
28
29
30
>
>>
Reviews
Be the First to Write a Review!
MA900 Multi-Application Cell Sorter from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top