Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
Antibody Discovery
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
MA900 Multi-Application Cell Sorter
Supplier Images
Published Figures
MA900 Multi-Application Cell Sorter
MA900 Multi-Application Cell Sorter from Sony Corporation
Be the first to write a review!
Citations:
(989)
Figures:
(7)
Inquire
from
Sony Corporation for
MA900 Multi-Application Cell Sorter
Description
MA900 multi-application cell sorter features ease of use, support for up to 12 fluorescence parameters and 4-way sorting.
Product Specs
Citations
Reviews
Product Specs
Item
MA900 Multi-Application Cell Sorter
Company
Sony Corporation
Price
Inquire
Catalog Number
MA900
Lasers
2 lasers
Excitation
405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), 561 nm (36 mW)
Parameters
14 parameters / 12 fluorescence channels
Capacity
Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
Data Throughput
70,000 events/sec (max)
Dimensions
(WxDxH) 55 x 55 x 72 cm
Add to Compare List
Citations (989)
(501)
Nicotinamide adenine dinucleotide rejuvenates septic bone marrow mesenchymal stem cells
World Journal of Stem Cells
February 26, 2025
Xin Xia, Kun Zhou, Lin-Ying An, Min Zhao, Bin-Le Tian, Jin-Yan Zhao, Zhi-Gang Zhou, Yin Tong
in the dark at 4 °C. The detailed
cell sorting
strategy is plotted in Supplementary Figure 1.
SONY
MA900
was used for sorting. β-galactosidase
staining
The cell layers were fixed at room temperature for
(502)
Characterization of Rationally Designed CRISPR/Cas9-Based DNA Methyltransferases with Distinct Methyltransferase and Gene Silencing Activities in Human Cell Lines and Primary Human T Cells
ACS Synthetic Biology
February 21, 2025
Rosa Selenia Guerra-Resendez, Samantha LeGoff Lydon, Alex J. Ma, Guy C. Bedford, Daniel R. Reed, Sunghwan Kim, Erik R. Terán, Tomoki Nishiguchi, Mario Escobar, Andrew R. DiNardo,
et al.
T cells
were sorted at day 8 post-transduction unless otherwise stated. All FACS was performed in a
Sony
MA900
Cell Sorter.
T Cell
Stimulation with PMA/Ionomycin 5 × 105 mCherry/EGFP double positive
T cells
were
(503)
Human Immune Cell Epigenomic Signatures in Response to Infectious Diseases and Chemical Exposures
bioRxiv
February 21, 2025
Wenliang Wang, Manoj Hariharan, Wubin Ding, Anna Bartlett, Cesar Barragan, Rosa Castanon, Vince Rothenberg, Haili Song, Joseph Nery, Andrew Aldridge,
et al.
CD56+) and other cells (CD3−, CD19−, CD14−, CD16−, CD56−). The
SONY
Multi-Application Cell Sorter LE-
MA900
Series was used to isolate single cells in 384-well PCR plates containing protein kinase. After
cell sorting
(504)
RNA sensing induced by chromosome missegregation augments anti-tumor immunity
Molecular Cell
February 20, 2025
Nobunari Sasaki, Mizuki Homme, Takahiko Murayama, Tatsuya Osaki, Toshiyuki Tenma, Tadaichi An, Yujiro Takegami, Tetsuo Tani, Patrick C. Gedeon, Yoshihisa Kobayashi,
et al.
MNs and PNs were filtered through cell strainer and then sorted by
flow cytometry
(
SONY
, Cell Sorter
MA900
) using 70 μm sorting chip.
IHC
staining
and analysis
Immunohistochemistry
was performed on the Leica
(505)
RELMβ sets the threshold for microbiome-dependent oral tolerance
Nature
February 20, 2025
Emmanuel Stephen-Victor, Gavin A. Kuziel, Monica Martinez-Blanco, Bat-Erdene Jugder, Mehdi Benamar, Ziwei Wang, Qian Chen, Gabriel L. Lozano, Azza Abdel-Gadir, Ye Cui,
et al.
pooled for isolation. Naïve CD4+ T cells (CD4+CD44−CD62L+) were isolated by
cell sorting
(
Sony
Sorter,
MA900
). Isolated
T cells
were seeded at a concentration of 1×106 cells/mL with plate-bound anti-CD3 (10 μg/mL)
(506)
Inhibition of acute lung inflammation by a neuroimmune circuit induced by vagal nerve stimulation
bioRxiv : the preprint server for biology
February 17, 2025
Murray K, Cremin M, Tay E, Sanchez K, Schreiber S, Brust-Mascher I, Leigh W, Ashfaq J, Gareau MG, Reardon C.
Tonbo Biosciences
) and anti-B220 PerCP-Cy5.5 (catalog no.
65-0452-U025
,
Tonbo Biosciences
) and sorted on
Sony
MA900
Cell Sorter. Genomic DNA was then extracted by resuspending cells in digestion buffer (50 mM KCl, 10
(507)
Massively parallel in vivo Perturb-seq screening
Nature Protocols
February 12, 2025
Xinhe Zheng, Patrick C. Thompson, Cassandra M. White, Xin Jin
Tubes with Cell strainer Snap Cap, 5mL (Fisher Scientific, cat. no. 0877123) FACS sorter, e.g.
SONY
MA900
or
Beckman
MoFlo Astrios
EQ
flow cytometer
Refrigerated swing bucket rotor centrifuge (e.g. Eppendorf
(508)
Pooled screening for CAR function identifies novel IL-13Rα2-targeted CARs for treatment of glioblastoma
J Immunother Cancer
February 11, 2025
Khloe S Gordon, Caleb R Perez, Andrea Garmilla, Maxine S Y Lam, Joey J Y Aw, Anisha Datta, Douglas A Lauffenburger, Andrea Pavesi, Michael E Birnbaum
flow analysis on a BD Accuri C6 or
Beckman
CytoFLEX S
or
cell sorting
with a BD
FACSAria
II or
Sony
MA900
. Anti-IL-13 (
clone
JES11-5A2), anti-CD213a2 (
clone
SHM38), anti-Flag (
clone
L5), anti-CD4 (
clone
SK3),
(509)
Transdermal microneedle-assisted ultrasound-enhanced CRISPRa system to enable sono-gene therapy for obesity
Nat Commun
February 10, 2025
Shaoyue Li, Jifeng Yu, Yuting Shen, Bing Xiong, De Zhao, Weichen Xu, Shen Zhang, Xin Guan, Yunyun Liu, Xuexia Shan,
et al.
BD Biosciences).
Data collection
was used with a multi-application cell sorter (
Sony Biotechnology
,
MA900
). For Calcein-AM/PI
staining
assay
, the preadipocytes were stained with Calcein-AM and PI solution for
(510)
Bi-allelic KICS2 mutations impair KICSTOR complex-mediated mTORC1 regulation, causing intellectual disability and epilepsy
The American Journal of Human Genetics
February 6, 2025
Rebecca Buchert, Martin D. Burkhalter, Chrisovalantou Huridou, Linda Sofan, Timo Roser, Kirsten Cremer, Javeria Raza Alvi, Stephanie Efthymiou, Tawfiq Froukh, Sughra Gulieva,
et al.
transfection
, the
transfected
cells expressing GFP were sorted as single cells into 96-well plates using an
MA900
cell sorter (
Sony Biotechnology
). The resulting single cells were then propagated, and
gene editing
(511)
Higher throughput assays for understanding the pathogenicity of variants of unknown significance (VUS) in the RPE65 gene
bioRxiv
February 5, 2025
Leila Azizzadeh Pormehr, Kannan Vrindavan Manian, Ha Eun Cho, Jason Comander
for FACS as described previously
for flow cytometry
. The stained cells were sorted on
Sony
SH800 or
MA900
FACS machines by their RPE65 expression level, where the “high” and “low” gates contained the top and
(512)
Influenza B virus infection alters the regenerative potential of murine alveolar type 2 pneumocytes
mBio
February 5, 2025
Satoko Nakano, Cait E. Hamele, Aleksandra Tata, Purushothama Rao Tata, Nicholas S. Heaton
AT2) cells were sorted using the Beckman Coulter MoFlo Astrios EQ High-speed Cell Sorter, the
Sony
MA900
Cell Sorter, or the Sony SH800 Cell Sorter. Culturing AT2
pneumocytes
ex vivo The collected cells
(513)
Flow-Cytometric Quantification of Urine Kidney Epithelial Cells Specifically Reflects Tubular Damage in Acute Kidney Diseases
Kidney International Reports
February 3, 2025
Leonie Wagner, Jacob Kujat, Valerie Langhans, Luka Prskalo, Diana Metzke, Emil Grothgar, Paul Freund, Nina Goerlich, Hannah Brand, Sara Timm,
et al.
urine.
Microscopy
The samples were prepared as described above and subsequently purified using a
Sony
MA900 multi-application cell sorter
(Sony Group Corporation, Minato, Tokyo, Japan). The resulting cell suspension was sorted directly on
(514)
H3K36 methylation regulates cell plasticity and regeneration in the intestinal epithelium
Nature Cell Biology
February 1, 2025
Alison R. S. Pashos, Anne R. Meyer, Cameron Bussey-Sutton, Erin S. O’Connor, Mariel Coradin, Marilyne Coulombe, Kent A. Riemondy, Sanjana Potlapelly, Brian D. Strahl, Gunnar C. Hansson,
et al.
Cells were sorted at the University of Colorado
Cancer
Center
Flow Cytometry
Shared Resource on a
Sony
MA900
with a 100 μm sorting chip or Beckman Coulter MoFlo XDP100 with a 100 μm nozzle tip.
Paneth Cell
scRNA-seq
(515)
Resident synovial macrophages in synovial fluid: Implications for immunoregulation
Clinical Immunology
February 1, 2025
Karen I. Cyndari, Breanna M. Scorza, Zeb R. Zacharias, Danielle Pessôa-Pereira, Leela Strand, Kurayi Mahachi, Juan Marcos Oviedo, Lisa Gibbs, Katherine L. Butler, Graham Ausdal,
et al.
30 minutes, washed, then resuspended in 50 μL of 4°C FACS buffer. Samples were then sorted on a
Sony
MA900
(San Jose, CA) with 100 μm sorting chip, sorting out CD66b+ and DAPI positive cells, then sorting on
(516)
Functional analysis of antigen presentation by enteric glial cells during intestinal inflammation
Glia
February 1, 2025
Ryan M. Brown, Helen H. Le, Isaac W. Babcock, Tajie H. Harris, Alban Gaultier
experiments. 2.4 FACS Sorting GFP-positive cells were sorted from primary EGC cultures using a
Sony
MA900
Cell Sorter and was performed by the University of Virginia Flow Cytometry Core Facility. 2.5
Flow Cytometry
(517)
PTEN loss in glioma cell lines leads to increased extracellular vesicle biogenesis and PD-L1 cargo in a PI3K-dependent manner
Journal of Biological Chemistry
February 1, 2025
Julio C. Sanchez, Timothy M. Pierpont, Dariana Argueta-Zamora, Kristin Wilson, Avery August, Richard A. Cerione
the resulting cell pellet was then resuspended in FACS buffer. Stained cells were sorted on a
Sony
MA900
with a 100 μm nozzle. Our gating strategy used empty vector
Jurkat cells
as a negative control for
PD-1
.
(518)
Prenatal Exposure to Chemotherapy Increases the Mutation Burden in Human Neonatal Hematopoietic Stem Cells
Cancer Discov
January 24, 2025
Ilana Struys, Carolina Velázquez, Joske Ubels, Charlotte L. LeJeune, Markus J. van Roosmalen, Axel K.M. Rosendahl Huber, Anais J.C.N. van Leeuwen, Wouter Bossuyt, Bernard Thienpont, Thierry Voet,
et al.
nmol/L, STEMCELL Technologies). Then, single neonatal HSPCs were sorted in 384-well plates by FACS (
Sony
MA900
cell sorter) using the following surface markers: CD34-BV421 (
1:20
, BioLegend, RRID: AB_11147951), lineage
(519)
Development of a Vaccine Candidate Based on Surface-Displayed Particles of Mycobacterium tuberculosis from the MTB39A Protein
Int J Mol Sci
January 18, 2025
Pu Wang, Gang Zhang, Lingling Jiang, Sinong Zhang, Weifeng Gao, Zhiwei Wu, Yong Li
647 Anti-Mouse IFN-γ (XMG1.2, Proteintech, Wuhan, China)). The cells were then detected with a
SONY
MA900
and analyzed using FlowJo 10.0 (Tree Star Inc., Ashland, OR, USA) software. 4.9. H&E
Staining
The
(520)
Single-cell analysis reveals Mycobacterium tuberculosis ESX-1-mediated accumulation of permissive macrophages in infected mouse lungs
Sci Adv
January 17, 2025
Weihao Zheng, Michael Borja, Leah C. Dorman, Jonathan Liu, Andy Zhou, Amanda Seng, Ritwicq Arjyal, Sara Sunshine, Alina Nalyvayko, Angela Oliveira Pisco,
et al.
using FlowJo software (TreeStar). To obtain MFI at time of cell sort, data were reviewed using the
Sony
MA900
software from sort of each run and using Boolean expression, tabulated for integration into the transcriptional
Page
<<
<
26
27
28
29
30
>
>>
Reviews
Be the First to Write a Review!
MA900 Multi-Application Cell Sorter from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top