Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
Antibody Discovery
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
MA900 Multi-Application Cell Sorter
Supplier Images
Published Figures
MA900 Multi-Application Cell Sorter
MA900 Multi-Application Cell Sorter from Sony Corporation
Be the first to write a review!
Citations:
(989)
Figures:
(7)
Inquire
from
Sony Corporation for
MA900 Multi-Application Cell Sorter
Description
MA900 multi-application cell sorter features ease of use, support for up to 12 fluorescence parameters and 4-way sorting.
Product Specs
Citations
Reviews
Product Specs
Item
MA900 Multi-Application Cell Sorter
Company
Sony Corporation
Price
Inquire
Catalog Number
MA900
Lasers
2 lasers
Excitation
405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), 561 nm (36 mW)
Parameters
14 parameters / 12 fluorescence channels
Capacity
Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
Data Throughput
70,000 events/sec (max)
Dimensions
(WxDxH) 55 x 55 x 72 cm
Add to Compare List
Citations (989)
(401)
T cell-specific non-viral DNA delivery and in vivo CAR-T generation using targeted lipid nanoparticles
J Immunother Cancer
July 13, 2025
Jaime Fernández Bimbo, Eline van Diest, Daniel E Murphy, Ator Ashoti, Martijn J W Evers, Suneel A Narayanavari, Diana Pereira Vaz, Hanneke Rijssemus, Christina Zotou, Nadine Saber,
et al.
via
flow cytometry
. To obtain a homogeneous
knockout
population, cells were bulk sorted using a
Sony
MA900
cell sorter.
Flow cytometry
CD19
CAR expression in
in vitro
experiments was detected using
CD19
CAR
(402)
Dissecting the epigenetic regulation of the fetal hemoglobin genes to unravel a novel therapeutic approach for β-hemoglobinopathies
Nucleic Acids Res
July 10, 2025
Simone Amistadi, Letizia Fontana, Chiara Magnoni, Tristan Felix, Matteo Kane Charvin, Pierre Martinucci, Candice Gautier, Lilian Greau, Bettina Bessières, Panagiotis Antoniou,
et al.
1/5000, BD) and hCD45-BV510 (dilution 1/100, BD). The hCD45low/−/CD235ahigh cells were sorted using the
MA900
cell sorter (
Sony
Biotechnology, San Jose, CA) and subjected to
DNA methylation
,
RT-qPCR
, RP-
HPLC
, and
(403)
DOCK8 in T cells promotes Th17 and Treg cell functionality to restrain mucosal mast cells and limit susceptibility to oral anaphylaxis
Immunity
July 8, 2025
Janssen E, Das M, Butts J, Alasharee M, Mukherjee S, Lozano GL, Rao C, Livingston AF, Woods B, Smith E,
et al
.
degranulation, CD4+CD25+eGFP+
Treg cells
were sorted from
Foxp3
-eGFP and
Foxp3
-eGFP/Dock8−/−
mice
using an
MA900
Cell Sorter (
Sony
).
Treg cells
were added at equal numbers to BMMCs along with anti-
CD3
+anti-
CD28
coated
(404)
Nuclear morphometrics coupled with machine learning identifies dynamic states of senescence across age
Nature communications
July 7, 2025
Mapkar SA, Bliss SA, Perez Carbajal EE, Murray SH, Li Z, Wilson AK, Piprode V, Lee YJ, Kirsch T, Petroff KS,
et al
.
102510
). Cells were then passed through 35 μm blue-top filters (
Falcon
,
352235
) and sorted using the
Sony
MA900 Multi-Application Cell Sorter
Software (Version 3.3.0) for an enriched fraction of
endothelial cells
(Enr-ECs), immune cells (ICs),
(405)
Impaired Aire-dependent IFN signaling in the thymus precedes the protective autoantibodies to IFNα
J Exp Med
July 7, 2025
Artur Stoljar, Maksym Zarodniuk, Rudolf Bichele, Elise Helene Armulik, Uku Haljasorg, Romain Humeau, Marine Besnard, Liis Haljasmägi, Liina Tserel, Merili Peltser,
et al.
following an overnight rest period in RPMI1640-media as described above. Cells were sorted using a
MA900
cell sorter (
Sony Biotechnology
) or analyzed with
LSRFortessa
flow cytometer
(
BD Bioscience
) or
SONY
(406)
Detecting and quantifying clonal selection in somatic stem cells
Nat Genet
July 3, 2025
Verena Körber, Niels Asger Jakobsen, Naser Ansari-Pour, Rachel Moore, Nina Claudino, Marlen Metzner, Eva Thielecke, Franziska Esau, Batchimeg Usukhbayar, Mirian Angulo Salazar,
et al.
1:10,000
Hoechst 33342 live–dead stain.
Cell sorting
was performed on a
BD
FACSAria
Fusion or
Sony
MA900
equipped with a 100-µm nozzle or sorting chip. Unstained, single-stained and
fluorescence
-minus-one
(407)
Injured tubule derived CCN1 exacerbates renal congestion-mediated acute kidney injury and fibrosis
Scientific reports
July 1, 2025
Minamida A, Nakata T, Kurose R, Sawai S, Nakamura M, Umehara M, Yamauchi-Sawada H, Sunahara Y, Matoba Y, Okuno-Ozeki N,
et al
.
resuspended in PBS and 10% fetal bovine serum (FBS) with 500:1 DAPI (2 mg/mL), and subjected to FACS using
MA900
(
SONY
). Dead cells (DAPI-positive cells) were excluded during FACS. tdTomato-positive and DAPI-negative
(408)
Mapping multimodal phenotypes to perturbations in cells and tissue with CRISPRmap
Nature biotechnology
July 1, 2025
Gu J, Iyer A, Wesley B, Taglialatela A, Leuzzi G, Hangai S, Decker A, Gu R, Klickstein N, Shuai Y,
et al
.
lentiviral transduction with pLV-EF1a-TagBFP2 on OE19 cells,
fluorescence-activated cell sorting
(
Sony
,
MA900
) was performed to obtain a BFP-expressing OE19 population. BFP-expressing OE19 (referred to as OE19–BFP)
(409)
Phenotypic changes associated with continuous long term in vitro expansion of bone marrow-derived mesenchymal stem cells
Biochimie
July 1, 2025
Vitali V. Maldonado, Hanna Jensen, C. Lowry Barnes, Rebekah M. Samsonraj
min and washed three times with FACS buffer. The surface marker expression was quantified using the
MA900 multi-application cell sorter
from
Sony Biotechnology
by obtaining 20000 intensity readings. To analyze cell morphology, BM-MSCs stained
(410)
CDH1 loss remodels gene expression and lineage identity in human mammary epithelial cells
bioRxiv
June 25, 2025
Maggie Musick, Chinasa A. Ufondu, Carmen E. Rowland, Joseph L. Sottnik, Madeleine T. Shackleford, Camryn S. Nesiba, Julie H. Ostrander, Matthew J. Sikora
with
EpCAM
-BV421 (Biolegend #
324220
,
clone
9C4, mouse IgG2b,
1:200
). Cells were sorted using the
Sony
MA900
. Gates were set using unstained controls. For
intracellular flow cytometry
, cells were harvested with
(411)
Mycobacterium tuberculosis PPE18 Protein Bodies in Insect Cells: A Candidate Tuberculosis Vaccine
Vaccines (Basel)
June 23, 2025
Pu Wang, Gang Zhang, Yurong Cai, Lingling Jiang, Xiaoxia Niu, Sinong Zhang, Weifeng Gao, Zhiwei Wu, Yong Li
647-conjugated Anti-Mouse IFN-γ (XMG1.2) antibodies. The stained cells were then analyzed using a
SONY
MA900
flow cytometer
, and the data were processed with FlowJo version 10 software (Tree Star Inc., Ashland,
(412)
The Frequency but not the Phenotype of Circulating Peripheral T Helper Cells is Increased at Later Stages of Progression to Type 1 Diabetes
Eur J Immunol
June 20, 2025
Anna-Mari Schroderus, Andrea Hanel, Céline Vandamme, Viola Pitkänen, Marja Rytkönen-Nissinen, Merja Heinäniemi, Mikael Knip, Riitta Veijola, Jorma Toppari, Jorma Ilonen,
et al.
instructions. Viable CD4+CD45RA−PD‐1hi and CD4+CD45RA−PD‐1lo
T cells
were sorted from each donor with the
Sony
MA900
cell sorter (Sony Biotechnology, Figure S14), and samples from different donors were pooled into PD‐1hi
(413)
Protection against lethal HAdV-4 challenge in STAT1 mice by novel human monoclonal antibodies
Frontiers in Immunology
June 19, 2025
Xinyi Zhang, Zhongge Zhu, Peijie Zhai, Peng Lv, You Yang, Chuanhang Cheng, Busen Wang, Ting Fang, Guanying Zhang, Xiangyang Chi,
et al.
After
staining
, the cells were washed twice with
cell staining
buffer. B cells were then sorted using a
MA900
cell sorter (
SONY
), with target cells defined as
CD3
−
CD19
+IgG+CD27+streptavidin+ (Hexon). Single cells
(414)
Model-guided design of microRNA-based gene circuits supports precise dosage of transgenic cargoes into diverse primary cells
Cell Systems
June 18, 2025
Kasey S. Love, Christopher P. Johnstone, Emma L. Peterman, Stephanie Gaglione, Michael E. Birnbaum, Kate E. Galloway
Trypsin-EDTA. Cells were resuspended in fresh DMEM + 10% FBS and sorted into polyclonal populations on a
Sony
MA900
Cell Sorter at the Koch Institute
Flow Cytometry
Core. Cells expressing the marker and/or output genes
(415)
Axillary adipose tissue-derived lymphatic endothelial cells exhibit distinct transcriptomic signatures reflecting lymphatic invasion status in breast cancer
Breast Cancer Res
June 17, 2025
Asumi Iesato, Jun Suzuka, Kazutaka Otsuji, Tomo Osako, Nami Yamashita, Yuka Inoue, Tetsuyo Maeda, Natsue Uehiro, Kazuyo Yoshida, Yoko Takahashi,
et al.
Labeled cells, resuspended in FACS buffer (5% fetal bovine serum in PBS), were sorted using a Cell Sorter
MA900
(
Sony
, Tokyo, Japan). Sorted cells were seeded in 6- plates or 24-well plates coated with collagen type
(416)
Transcriptional fingerprinting of regulatory T cells: ensuring quality in cell therapy applications
Front Immunol
June 16, 2025
Zhang Cheng, Li-Jie Wang, Yuchi Honaker, Steven A. Cincotta, Claire E. Page, Sydney Vollhardt, Victor Yuan, S. Alice Long, Yuanyuan Xiao, Joshua N. Beilke,
et al.
Enriched CD25+ cells were then stained by anti-CD4/CD25/CD127 before Treg and
Teff
isolation by FACS (
Sony
MA900
). Purified cells were then either frozen (D0) or activated and expanded for 14 days in CTS™ OpTmizer™
(417)
Common AAV gene therapy vectors show nonselective transduction of ex vivo human brain tissue
Molecular Therapy Methods & Clinical Development
June 12, 2025
J P McGinnis, Joshua Ortiz-Guzman, Maria Camila Guevara, Sai Mallannagari, Benjamin D.W. Belfort, Suyang Bao, Snigdha Srivastava, Maria Morkas, Emily Ji, Angela Addison,
et al.
SmartStrainer, centrifuged, and resuspended in ∼250–500 μL. Nuclei were then FACS sorted using DAPI on a
Sony
MA900
in the Baylor
Cytometry
and
Cell Sorting
Core. Library preparation The single-cell
gene expression
(418)
Feature-specific threat coding in lateral septum guides defensive action
ResearchSquare
June 12, 2025
Dionnet Leandro Bhatti Fishell, Dionnet Bhatti Pasqualini, Sherry Jingjing Pasqualini, Marc Z.C. Berger, Christopher M. Berger, Salvador Ignacio Brito, Salvador Brito, Shenfeng Levitt, Todd Erryl Anthony, Todd Anthony
filtered through a 40 μm strainer, and stained with DAPI. GFP-positive nuclei were isolated on a
Sony
MA900
sorter using a 70 μm nozzle (see Supplemental Methods). Sorted nuclei were collected into chilled 0.2
(419)
Rewriting regulatory DNA to dissect and reprogram gene expression
Cell
June 12, 2025
Gabriella E. Martyn, Michael T. Montgomery, Hank Jones, Katherine Guo, Benjamin R. Doughty, Johannes Linder, Deepa Bisht, Fan Xia, Xiangmeng S. Cai (蔡向濛), Ziwei Chen,
et al.
detect small effect sizes) into 4 bins based on the
fluorescence
intensity of the target gene using the
MA900 Multi-Application Cell Sorter
(
Sony
). For splice site disruption and motif insertion experiments, we sorted up to 6 million cells
(420)
Immunotherapy-related cognitive impairment after CAR T cell therapy in mice
Cell
June 12, 2025
Anna C. Geraghty, Lehi Acosta-Alvarez, Maria C. Rotiroti, Selena Dutton, Michael R. O’Dea, Wonju Kim, Vrunda Trivedi, Rebecca Mancusi, Kiarash Shamardani, Karen Malacon,
et al.
filtered through a 40 μm cell strainer into FACS tubes immediately prior to FACS sorting using a
Sony
MA900
sorter with a 70 μm chip. A standard gating strategy was applied to all samples. First, nuclei were
Page
<<
<
21
22
23
24
25
>
>>
Reviews
Be the First to Write a Review!
MA900 Multi-Application Cell Sorter from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top