BioLegend
Anti-mouse CD45.1 BV510
110741
Info:Supplier Page View Product SpecsView Product
Browse Similar Products: CD45.1 Flow Cytometry Antibodies
Our lab studies the function of T cells in an influenza model in mice. Sometimes we use a model where we transfer cells from one mouse environment to another so we can see the effect of that new environmental on the cells. In order to do that, we use CD45.1 mice and therefore need a good marker to visualize these CD45.1 cells and separate them from the other mouse cells. This antibody works well for us.
Flow Cytometry
Mouse blood
Cells were stained in 100 µL FACS buffer with antibody at 1:100 for 1 hour on ice and in the dark. Cells were washed with FACS buffer and run in 100 µL FACS buffer.
FACS buffer
N/A
LSR II
This antibody works pretty well to see separation between CD45.1+ and – cells.
Stable
NONE
This antibody works efficiently to stain CD45.1 specific cells from mouse blood.