As technology advances and the costs go down, single-cell RNA sequencing (scRNAseq) is replacing bulk sequencing for examining transcriptomics changes occurring at the cellular level. Single-cell analysis sheds light on the individual contributions of a cell population to the biological response and offers a high-resolution view of the heterogeneity that exists in a tissue sample. Along with scRNAseq, there is now single-nucleus RNA sequencing (snRNAseq), which captures changes occurring at the nuclear level.

While scRNASeq involves dissociating the tissue sample into a single-cell suspension, snRNASeq involves lysing the cells to obtain the nuclei before sequencing. Both techniques have their own advantages and limitations and, therefore, it would be ideal to use both techniques to get a complete picture of the biology being studied. However, since the cells need to be lysed to perform snRNAseq, it has to be one or the other when studying a single cell. This article summarizes the perspectives shared by the speakers in a recent Bench Tips webinar titled, Single Cell Analysis for Spatial Studies.
Comparing information from scRNAseq vs snRNAseq
If there is enough sample available to conduct both scRNAseq and snRNAseq, then the decision comes down to time and costs. But if there isn’t, then it is imperative to understand how each technique works and what information they can provide in order to make the right choice. The choice largely depends on the type of sample, or the specific cell being studied, and the biological question that needs to be answered. The table below summarizes some of the pros and cons of each technique.
| Single-cell RNA-Seq | Single-nucleus RNA-Seq |
|---|
Pros- Captures cytoplasmic and nuclear transcripts
- Enhanced capture of immune cells for disease studies
- Large number of datasets have been generated
Cons- Tissue needs to be fresh
- Dissociation induces stress response which can impact data interpretation
- Biases toward cells that survive dissociation process
| Pros- Can be used on archived samples (fixed or frozen)
- Improved capture of hard to dissociate or fragile cells
Cons- Depletion of immune cells
- Capture of mostly unspliced pre-mRNA
|
Both scRNA and snRNAseq can accurately profile gene expression changes and there is often good correlation between the data. Some of the observed discrepancies can be attributed to the fact that the cytoplasm is removed during snRNAseq and, hence, the transcripts obtained are mostly unspliced pre-mRNA. Sometimes the protocols used and factors like dissociation times and stress response can also impact the availability or enrichment of certain cell types, which, in turn, affects the data obtained.
snRNAseq is better when working with fragile and difficult-to-dissociate cell types, and the cell type proportions obtained are more representative of the actual cell composition. snRNAseq, on the other hand, is a good alternative for labs that need to wait and obtain all their samples before they can be analyzed. The samples can be frozen and stored until ready for snRNAseq, thereby saving some processing costs and also minimizing batch effects. The samples for scRNAseq have to be processed fairly quickly and cannot be frozen. It’s evident that using both scRNAseq and snRNAseq to analyze the sample is ideal and using just one of the techniques is likely to lead to missing some interesting biology.
Sample preparation is critical for all transcriptomic analysis
Numerous sampling protocols exist for use in a variety of tissues, and each step needs to be optimized for the type and amount of sample used. Sample preparation also varies based on what other downstream analysis is going to be carried out. For instance, if spatial analysis is planned it’s best not to have the samples fixed. Here are some sample preparation tips:
- Good single-cell suspension is a must for scRNAseq
- It’s important to have high cell viability
- Cell debris and dying cells release RNA, leading to contamination. They can potentially be removed by density gradients, bead removal kits, or by flow sorting
- Centrifugation speeds and time needs to be optimized
- It is critical to optimize the lysis time so the nuclear membrane is not compromised for snRNAseq
- Filtering and addition of DNAse can remove/reduce cell clumping
- Certain experiments may require cell enrichment based on a marker by magnetic or fluorescent sorting
Resources by application
| Category | Tools/Methods |
|---|
| Single-cell data integration | |
| Cell annotation | |
| Comparative single-cell analysis | |
| RNA velocity | |
| Slide-seq data annotation | |
| Single-cell copy number variations analysis | |
| Cell-cell interactions | |
Community tools and tutorials
https://www.scrna-tools.org/
https://satijalab.org/seurat/articles/seurat5_integration
https://cole-trapnell-lab.github.io/monocle3/
http://www.cellchat.org/
https://scenicplus.readthedocs.io/en/latest/
https://www.bioconductor.org/
https://scanpy.readthedocs.io/en/stable/
https://bioconductor.org/packages/devel/bioc/vignettes/slingshot/inst/doc/vignette.html
https://scvelo.readthedocs.io/en/stable/
https://bioconductor.org/packages/release/bioc/html/scDblFinder.html
https://github.com/kharchenkolab/conos
https://portals.broadinstitute.org/harmony/articles/quickstart.html
https://bioconductor.org/packages/release/bioc/html/SingleR.html
https://rdrr.io/github/dmcable/RCTD/f/vignettes/spatial-transcriptomics.Rmd
https://kharchenkolab.github.io/numbat/
https://bioconductor.org/packages/release/bioc/html/infercnv.html