
Flow cytometry kits contain specialized reagents designed for flow cytometric cellular analysis. These kits will generally include unique conjugated antibodies and fluorescent dyes or reporter molecules for the detection of target antigens or cells. They can be used to detect specific proteins, such as Annexin V, cells like macrophages, enzymes such as caspases and phosphatases, as well as processes such as autophagy. Streptavidin-coated, bead-based flow cytometry kits that can be used for the detection of biotinylated targets are also available. Flow cytometry kits can be used for studying immunology, cell viability and apoptosis, epigenetics, cell proliferation, and cell signaling. Protein expression and post-translational modifications can also be studied using these kits. Visit the supplier page for more product information, such as quantity, assay type, and detection target.
Your search returned 50 Flow Cytometry Kits across 1 supplier.
Get pricing for all products
Select up to 5 products from below to compare or request more information.
Sponsored Products
- Background: FLICA is a powerful method to assess cell death by detecting apoptosis in vitro. FLICA probes are non-...
- 2x100 Tests
- Flow Cytometer, Fluorescence Microscope, Fluorescence Plate ...
Read More
- Background: FLICA is a powerful method to assess cell death by detecting apoptosis in vitro. FLICA probes are non-...
- 4x100 Tests
- Flow Cytometer, Fluorescence Microscope, Fluorescence Plate ...
Read More
- Background: FLICA is a powerful method to assess cell death by detecting apoptosis in vitro. FLICA probes are non-...
- 100 Tests
- Flow Cytometer, Fluorescence Microscope, Fluorescence Plate ...
Read More
- Background: FLICA is a powerful method to assess cell death by detecting apoptosis in vitro. FLICA probes are non-...
- 5x100 Tests
- Flow Cytometer, Fluorescence Microscope, Fluorescence Plate ...
Read More
- The lymphocyte activation gene-3 (LAG3) is a member of the immunoglobulin superfamily and binds MHC class II with high ...
- 1 Set, 3x1 Set, 5x1 Set, 2x1 Set, 4x1 Set
- FCM/FACS (Flow Cytometry), IF (Immunofluorescence), IHC (...
Read More
- ApoScreen® Annexin V Apoptosis Kit-FITC (Cat. No. MBS678004) employs a fluorescein-conjugated Annexin V (Annexin V-...
- 5x100 Tests, 3x100 Tests, 100 Tests, 4x100 Tests, 2x100 ...
- FCM/FACS (Flow Cytometry)
Read More
- Description: The FLICA 660 caspase-1 kit uses a target sequence (YVAD) sandwiched between a far-red fluorescent 660 dye ...
- 2x25 Tests, 4x25 Tests, 25 Tests, 5x25 Tests, 3x25 Tests
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Background: FLICA is a powerful method to assess cell death by detecting apoptosis in vitro. FLICA probes are non-...
- 3x100 Tests
- Flow Cytometer, Fluorescence Microscope, Fluorescence Plate ...
Read More
- Background: FLICA is a powerful method to assess cell death by detecting apoptosis in vitro. FLICA probes are non-...
- 25 Tests
- Flow Cytometer, Fluorescence Microscope, Fluorescence Plate ...
Read More
- 2x1 mL, 5x1 mL, 4x1 mL, 1 mL, 3x1 mL
- FCM/FACS (Flow Cytometry)
- Background: Nitric oxide synthases are a family of enzymes capable of catalyzing the production of nitric oxide (NO). NO...
- 50 Tests, 3x50 Tests, 2x50 Tests, 5x50 Tests, 4x50 Tests
- Fluorescence Plate Reader, FM (Fluorescence Microscopy), FCM...
Read More
- Ubiquitin C-terminal hydrolase 1 (UCHL1) was independently discovered by several different research groups and so has ...
- 2x1 Kit, 4x1 Kit, 1 Kit, 3x1 Kit, 5x1 Kit
- FCM/FACS (Flow Cytometry)
Read More
- Principle of the Assay: Caspase FLICA kits measure apoptosis by detecting active caspases in whole, living cells. These ...
- 2x25 Tests, 4x25 Tests, 25 Tests, 5x25 Tests, 3x25 Tests
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Principle of the Assay: Caspase FLICA Kits measure apoptosis by detecting active caspases in whole, living cells. These ...
- 5x100 Tests, 3x100 Tests, 100 Tests, 4x100 Tests, 2x100 ...
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Description: The FAM FLICA Caspase 6 kit uses a quick and easy method to analyze active caspases in apoptotic cells.
Test... - 5x100 Tests, 3x100 Tests, 100 Tests, 4x100 Tests, 2x100 ...
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Description: The FAM FLICA Caspase 6 kit uses a quick and easy method to analyze active caspases in apoptotic cells.
Test... - 2x25 Tests, 4x25 Tests, 25 Tests, 5x25 Tests, 3x25 Tests
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Description: The FAM FLICA Caspase 8 kit uses a quick and easy method to analyze active caspases in apoptotic cells.
Test... - 5x100 Tests, 3x100 Tests, 100 Tests, 4x100 Tests, 2x100 ...
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Description: The FAM FLICA Caspase 8 kit uses a quick and easy method to analyze active caspases in apoptotic cells.
Test... - 2x25 Tests, 4x25 Tests, 25 Tests, 5x25 Tests, 3x25 Tests
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Description: The FAM FLICA Caspase 9 kit uses a quick and easy method to analyze active caspases in apoptotic cells.
Test... - 5x100 Tests, 3x100 Tests, 100 Tests, 4x100 Tests, 2x100 ...
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Description: The FAM FLICA Caspase 9 kit uses a quick and easy method to analyze active caspases in apoptotic cells.
Test... - 2x25 Tests, 4x25 Tests, 25 Tests, 5x25 Tests, 3x25 Tests
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- The FoxP3 / Transcription Factor Staining Kit has optimized for staining with antibodies to transcription factors and ...
- 2x1 Kit, 4x1 Kit, 1 Kit, 3x1 Kit, 5x1 Kit
- FCM/FACS (Flow Cytometry)
Read More
- Description: Green Cathepsin B Kit enables the quantitation and monitoring of intracellular cathepsin activity over time...
- 2x25 Tests, 4x25 Tests, 25 Tests, 5x25 Tests, 3x25 Tests
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Description: Green Cathepsin B Kit enables the quantitation and monitoring of intracellular cathepsin activity over time...
- 5x100 Tests, 3x100 Tests, 100 Tests, 4x100 Tests, 2x100 ...
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Background/Introduction: Exposure of inflammatory effector cells like monocytes and macrophages to pathogen-associated ...
- 5x100 Tests, 3x100 Tests, 100 Tests, 4x100 Tests, 2x100 ...
- Fluorescence Plate Reader, FM (Fluorescence Microscopy), FCM...
Read More
- Description: Pyroptosis 660 Caspase-1 Kit utilizes the popular FLICA technology to detect caspase-1 activation. This ...
- 2x25 Tests, 4x25 Tests, 25 Tests, 5x25 Tests, 3x25 Tests
- IF (Immunofluorescence), FCM/FACS (Flow Cytometry)
Read More
- Annexin V is a phospholipid phosphatidylserine (PS) binding protein. In the earlier stages of apoptosis, PS is ...
- 2x1 Kit, 4x1 Kit, 1 Kit, 3x1 Kit, 5x1 Kit
- FCM/FACS (Flow Cytometry)
Read More
- Principle of the Assay: Annexin V is a phospholipid phosphatidylserine (PS) binding protein. In the earlier stages of ...
- 2x1 Kit, 4x1 Kit, 1 Kit, 3x1 Kit, 5x1 Kit
- FCM/FACS (Flow Cytometry)
Read More
- Principle of the Assay: Apoptosis or programmed cell death is an evolutionary conserved, intrinsic program of cell death...
- 5x100 Tests, 3x100 Tests, 100 Tests, 4x100 Tests, 2x100 ...
- FCM/FACS (Flow Cytometry)
Read More
- Background: Autophagy is a conserved lysosomal recycling process by which cells break down their own components such as ...
- 200 Tests, 3x200 Tests, 5x200 Tests, 2x200 Tests, 4x200 ...
- FCM/FACS (Flow Cytometry)
Read More
- Principle of the Assay: Autophagy Probe, Red is a cell-permeant aliphatic molecule that fluoresces brightly when ...
- 50 Tests, 3x50 Tests, 2x50 Tests, 5x50 Tests, 4x50 Tests
- FCM/FACS (Flow Cytometry)
Read More
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags