Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Assay Kits
Assay Kit
ROS-Glo H2O2 Assay
Supplier Images
Published Figures
ROS-Glo H2O2 Assay
ROS-Glo H2O2 Assay
ROS-Glo H2O2 Assay from Promega
Be the first to write a review!
Citations:
(140)
Figures:
(1)
Supplier Page
Supplier Page from
Promega for
ROS-Glo H2O2 Assay
Get Pricing
Ask a Question
Description
The ROS-Glo H2O2 Assay is a homogeneous, fast and sensitive bioluminescent assay that measures the level of hydrogen peroxide (H2O2), a reactive oxygen species (ROS), directly in cell culture or in defined enzyme reactions
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
ROS-Glo H2O2 Assay
Company
Promega
Price
$354.00
Supplier Page
View Company Product Page
Catalog Number
G8820
Quantity
10ml
Reactivity
mammal
Sample Type
cells in culture, tissue
Detection Target
H2O2
Assay Time
20 minutes
Molecular Weight
~104kDa
Add to Compare List
Promega
2800 Woods Hollow Rd
Madison
,
WI
53711
United States
Phone
: Tel: +1 (608) 274-4330
Fax: +1 (608) 277-2516
Email: custserv@promega.com
techserv@promega.com
Company Profile
Website:
http://www.promega.com
Citations (140)
(21)
Non-canonical dihydrolipoyl transacetylase promotes chemotherapy resistance via mitochondrial tetrahydrofolate signaling
Nat Commun
October 8, 2025
Jung Seok Hwang, JiHoon Kang, Jaehyun Kim, Kiyoung Eun, Sophia West, Hannah E. Bacho, Vanessa Avalos, Sydney Shuff, Dong M. Shin, Nabil F. Saba,
et al.
(
89874
) was obtained from
Pierce
. MitoTracker Red CMXros (
M7512
) was from
Invitrogen
.
ROS-Glo H2O2 Assay
(
G8820
),
NADP/NADPH-Glo Assay
(
G9081
), and
GSH/GSSG-Glo Assay
(
V6611
) were procured from
Promega
. MtioSOX (
M36008
)
(22)
Spinocerebellar Ataxia Type 1 (SCA1) Cell Models Display Widespread Mitochondrial and Extra-Nuclear Alterations
J Mol Neurosci
October 2, 2025
Dane Ford-Roshon, Madison Dudek, Ada Glynn, Abigale Glasman, Jaden York, Emily Lawrence, Donna Nguyen, Lindsay Shinn, Georgia Berry, Lily Kendall,
et al.
long half-life, was measured in WT Daoy and ATXN1[82Q] cells using the
ROS-Glo H2O2 Assay
kit (
Promega
G8820
). Harvested cells were plated at a concentration of 3000 Daoy cells or 5000 ATXN1[82Q] cells, to account
(23)
The NLRP3 Inflammasome Transmits Sterile Inflammation Signals to Sustain Proper Mitochondrial Electron Transport Chain Function and Influences Cellular Metabolism
Stem Cell Reviews and Reports
October 1, 2025
Adrian Konopko, Michalina Kazek, Emilia Waraksa-Zasada, Agnieszka Łukomska, Janina Ratajczak, Magdalena Kucia, Mariusz Z. Ratajczak
and Nlrp3-KO BM was measured using the
ROS-Glo™ H2O2 Assay
(
Promega
, Madison, WI, USA, Catalog No.
G8820
) following the manufacturer’s instructions. Control cells (untreated) and cells treated with eATP (1
(24)
Dynamic regulation of the oxidative stress response by the E3 ligase TRIP12
Cell Reports
September 23, 2025
Andrew J. Ingersoll, Devlon M. McCloud, Jenny Y. Hu, Michael Rape
shown. ROS measurements Cellular levels of H2O2 were determined using the
ROS-Glo™ H2O2 Assay
(
Promega
,
G8820
) according to manufacturer’s instructions.
qPCR
C2C12 cells were
transfected
with siRNAs and RNA was
(25)
Mechanistic Insights into the Anticancer Action of Novel 2-Hydroxy-1,4-naphthoquinone Thiol Derivatives
ACS Omega
September 16, 2025
Thaís Barreto Santos, Alex de Souza Cruz Lopes Canuto, João Francisco Blaudt Virgilio de Carvalho Meira, Ana Caroline Santos-Diniz, Rafaella Machado de Assis Cabral Ribeiro, Caroline Reis Santiago Paschoal, Vitor Won-Held Rabelo, Paula Alvarez Abreu, Vitor Francisco Ferreira, David Rodrigues da Rocha,
et al.
then incubated at 37 °C with 5% CO2 for the indicated time, and ROS was measured by
ROS-Glo H2O2 Assay
G8820
(
Promega Corporation
, Madison, WI 53711 USA) as indicated by the vendor. The
luminescence
signal was
(26)
Exposure to Bisphenol S and Bisphenol F Alters Gene Networks Related to Protein Translation and Neuroinflammation in SH-SY5Y Human Neuroblastoma Cells
Toxics
September 12, 2025
Andrea P. Guzman, Christina L. Sanchez, Emma Ivantsova, Jacqueline Watkins, Sara E. Sutton, Christopher L. Souders, Christopher J. Martyniuk
Supplemental Methods. ROS production was measured using (1) the
ROS-Glo™ H2O2 Assay
(
Promega
, Cat #
G8820
) as per the manufacturer’s protocol and (2) with the fluorescent probe DCFDA (2′,7′-dichlorofluorescein
(27)
Sodium-glucose cotransporter 2 inhibitors ameliorate glutathione cysteine ligase modifier-mediated oxidative stress and subsequent ferroptosis in proximal tubules of diabetic kidney disease
Redox Rep
July 29, 2025
Yi-Chun Tsai, Jiun-Chi Huang, Ping-Shaou Yu, Mei-Chuan Kuo, Ling-Yu Wu, Wei-An Chang, Shang-Jyh Hwang, Ya-Ling Hsu
wavelengths of 380 and 485 nm, respectively. To assess the ROS levels, the
ROS-Glo H2O2 Assay
system (Cat No.
G8820
,
Promega
, WI, USA) was used according to the manufacturer’s instructions.
Cultured cells
were trypsinized,
(28)
Peptide YY fragment PYY1-36 disrupts mitochondrial biogenesis via RBM43-dependent PGC-1α translation inhibition
Investigational New Drugs
June 1, 2025
Benkun Liu, Fucheng Zhou, Bowen Shi, Yubo Yan, Yanbo Wang, Junfeng Wang, Yaoguo Lang, Shidong Xu
N-acetylcysteine, NAC, Sigma-Aldrich,
A7250
, for 1 h before 100 nM PYY1-36). The ROS-Glo H₂O₂
Assay
(
Promega
,
G8820
) was performed per the manufacturer’s protocol, as an alternative to
flow cytometry
due to poor-quality
(29)
IL-6-mediated tumorigenicity and antioxidant state in squamous cell carcinoma cells are driven by CD109 via stabilization of IL-6 receptor-alpha and activation of STAT3/NRF2 pathway
Exp Hematol Oncol
May 2, 2025
Amani Hassan, Tenzin Kungyal, Shufeng Zhou, Meryem Blati, Kenneth Finnson, Nick Bertos, Nahid Golabi, Nader Sadeghi, Sampath Loganathan, Anie Philip
ROS-Glo™ H2O2 assay
ROS levels were measured using
ROS-Glo™ H2O2 Assay
kit from
Promega
(
Promega
; #
G8820
) according to manufacturer’s instructions. A431WT, SCC9 WT and their corresponding
CD109
KO cells were
(30)
Exploiting the therapeutic vulnerability of IDH-mutant gliomas with zotiraciclib
iScience
April 18, 2025
Ying Pang, Qi Li, Zach Sergi, Guangyang Yu, Olga Kim, Peng Lu, Marina Chan, Xueyu Sang, Herui Wang, Alice Ranjan,
et al.
commercial
assays
,Critical commercial
assays
,Critical commercial
assays
,,
ROS-Glo H2O2 assay
kit,
Promega
,
G8820
Caspase-Glo 3/7 Assay
Kit,
Promega
,
G8091
Seahorse
XF Cell Mito Stress Test Kit
,
Agilent
,
103015-100
Seahorse
(31)
Signaling and transcriptional dynamics underlying early adaptation to oncogenic BRAF inhibition
Cell Systems
April 16, 2025
Cameron T. Flower, Chunmei Liu, Hui-Yu Chuang, Xiaoyang Ye, Hanjun Cheng, James R. Heath, Wei Wei, Forest M. White
hour prior to ROS quantitation. ROS levels were quantified by
ROS-Glo H2O2 Assay
(
Promega
, catalog #
G8820
) according to the manufacturer’s protocol. The
luminescence
signals were measured by the Synergy H4
(32)
Chaperone-mediated autophagy regulates the metastatic state of mesenchymal tumors
EMBO Molecular Medicine
March 7, 2025
Xun Zhou, Eva Berenger, Yong Shi, Vera Shirokova, Elena Kochetkova, Tina Becirovic, Boxi Zhang, Vitaliy O Kaminskyy, Yashar Esmaeilian, Kayoko Hosaka,
et al.
Test Kit,Seahorse Bioscience,103010-100 G6PDH Assay Kit,
Abcam
,
ab102529
ROS-Glo H2O2 assay
,
Promega
,
G8820
Software,Software,Software R (v 4.0.5),https://www.r-project.org/, tximport package (v 1.26.1),https://bioconductor.org/packages/release/bioc/html/tximport.html, clusterProfiler
(33)
Calcium electroporation induces stress response through upregulation of HSP27, HSP70, aspartate β-hydroxylase, and CD133 in human colon cancer cells
Biol Res
February 21, 2025
Anna Szewczyk, Nina Rembiałkowska, Jolanta Saczko, Małgorzata Daczewska, Vitalij Novickij, Julita Kulbacka
viable cells relative to untreated controls. ROS level investigation The ROS-Glo™ H₂O₂
Assay
(
Promega
,
G8820
) is a sensitive
bioluminescent assay
that directly
measures
cell culture
’s reactive oxygen species (ROS)
(34)
The AMD-associated genetic polymorphism CFH Y402H confers vulnerability to Hydroquinone-induced stress in iPSC-RPE cells
Front Immunol
February 6, 2025
Angela Armento, Inga Sonntag, Ana-Cristina Almansa-Garcia, Merve Sen, Sylvia Bolz, Blanca Arango-Gonzalez, Ellen Kilger, Ruchi Sharma, Kapil Bharti, Rosario Fernandez-Godino,
et al.
fluorescence
and
luminescence measurements
. Levels of H2O2 were
measure
using the
ROS-Glo H2O2 assay
(
G8820
,
Promega
) and
assay
was performed according to manufacturer instructions. Briefly, cells were exposed
(35)
RNF7‐Mediated ROS Targets Malignant Phenotype and Radiotherapy Sensitivity in Glioma With Different IDH1 Genotypes
Molecular Carcinogenesis
January 9, 2025
Yiran Tao, Zimin Shi, Xianyin Liang, Yuqian Zheng, Lirui Dai, Xiang Li, Zian Li, Wulong Liang, Gaojie Bai, Hao Li,
et al.
using the Reactive Oxygen Species Assay Kit (Beyotime, S0033S) or the
ROS‐Glo H2O2 assay
kit (
Promega
,
G8820
). Following the manufacturer's protocols, the treated samples were examined using a
fluorescence microscope
(36)
Evaluating the Antibacterial Potential of Distinct Size Populations of Stabilized Zinc Nanoparticles
ACS Applied Materials & Interfaces
January 8, 2025
Dinny Stevens, Amanda K. Charlton-Sevcik, W. Evan Braswell, Christie M. Sayes
h exposure was measured through H2O2 production using the Luminescent
ROS-Glo H2O2 assay
(
Promega
, #
G8820
). The positive control for ROS production was 200 μM menadione (Thermo Fisher Scientific).
Bacteria
(37)
Pharmacological Vitamin C-induced high H2O2 generation mediates apoptotic cell death by caspase 3/7 activation in breast cancer tumor spheroids
J Transl Med
January 8, 2025
Ali Mussa, Mahasin Hamid, Khalid Hajissa, Ahmad Hafiz Murtadha, Mohammad A. I. Al-Hatamleh, Noor Fatmawati Mokhtar, Vuk Uskoković, Magdalena Plebanski, Rohimah Mohamud, Rosline Hassan
Vit-C doses for 72 h, the cellular ROS was determined by performing the
ROS-GLO™ H2O2 ASSAY
(PROYY-
G8820
,
Promega
, USA) according to the protocol from the manufacturer. In short, from the H2O2 substrate solution
(38)
β-Lapachone promotes the recruitment and polarization of tumor-associated neutrophils (TANs) toward an antitumor (N1) phenotype in NQO1-positive cancers
OncoImmunology
December 31, 2024
Soumya Tumbath, Lingxiang Jiang, Xiaoguang Li, Taolan Zhang, Kashif Rafiq Zahid, Ye Zhao, Hao Zhou, Zhijun Yin, Tao Lu, Shu Jiang,
et al.
and anti-HMGB1 monoclonal antibodies were purchased from BioXCell (Lebanon, NH). ROS-GloTM
assay
kit (
G8820
) was obtained from
Promega
(Madison, WI). TACSTM Annexin V-FITC apoptosis detection kit was purchased
(39)
Efficacy of glutathione inhibitor eprenetapopt against the vulnerability of glutathione metabolism in SMARCA4-, SMARCB1- and PBRM1-deficient cancer cells
Scientific Reports
December 28, 2024
Mariko Sasaki, Hideaki Ogiwara
GSH/GSSG-Glo Assay
(
Promega
,
V6611
), the GSH-Glo
Assay
(
Promega
,
V6911
), the
ROS-Glo H2O2 Assay
(
Promega
,
G8820
), and the
Caspase-Glo 3/7 Assay
(
Promega
,
G8091
), respectively. To
measure
levels of GSH/GSSG, ROS,
(40)
Reactive oxygen species control protein degradation at the mitochondrial import gate
Molecular Cell
December 5, 2024
Rachael McMinimy, Andrew G. Manford, Christine L. Gee, Srividya Chandrasekhar, Gergey Alzaem Mousa, Joelle Chuang, Lilian Phu, Karen Y. Shih, Christopher M. Rose, John Kuriyan,
et al.
commercial
assays
,Critical commercial
assays
,Critical commercial
assays
ROS-Glo H2O2 Assay
,
Promega
,Cat#
G8820
Ionic Detergent Compatibility Reagent,
Thermo Fisher Scientific
,Cat#
22663
Pierce 660nm Protein Assay Reagent
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
ROS-Glo H2O2 Assay from Promega
Supplier Page
View Company Product Page
$354.00
Product Specs
Company Info
Citations
Reviews
Back To Top