Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
Antibody Discovery
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
MA900 Multi-Application Cell Sorter
Supplier Images
Published Figures
MA900 Multi-Application Cell Sorter
MA900 Multi-Application Cell Sorter from Sony Corporation
Be the first to write a review!
Citations:
(989)
Figures:
(7)
Inquire
from
Sony Corporation for
MA900 Multi-Application Cell Sorter
Description
MA900 multi-application cell sorter features ease of use, support for up to 12 fluorescence parameters and 4-way sorting.
Product Specs
Citations
Reviews
Product Specs
Item
MA900 Multi-Application Cell Sorter
Company
Sony Corporation
Price
Inquire
Catalog Number
MA900
Lasers
2 lasers
Excitation
405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), 561 nm (36 mW)
Parameters
14 parameters / 12 fluorescence channels
Capacity
Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
Data Throughput
70,000 events/sec (max)
Dimensions
(WxDxH) 55 x 55 x 72 cm
Add to Compare List
Citations (989)
(681)
Protocol for gene knockdown using siRNA in primary cultured neonatal murine microglia
STAR Protocols
March 15, 2024
Yuma Kato, Sho Takatori, Aika Akahori, Hayato Etani, Yung Ning Chu, Taisuke Tomita
,
Merck Millipore
,Cat#
SLGV033RS
Nunc EasYFlask 75 cm2,Thermo Fisher Scientific,Cat#156472 Multi-application cell sorter
MA900
,
Sony
,N/A
ImageQuant LAS 4000
,
Cytiva
,N/A
Leica
S8 APO
unique Greenough stereo microscope with apochromatic
(682)
The neuroimmune CGRP–RAMP1 axis tunes cutaneous adaptive immunity to the microbiota
Proceedings of the National Academy of Sciences
March 12, 2024
Warakorn Kulalert, Alexandria C. Wells, Verena M. Link, Ai Ing Lim, Nicolas Bouladoux, Motoyoshi Nagai, Oliver J. Harrison, Olena Kamenyeva, Juraj Kabat, Michel Enamorado,
et al.
sorted as
DAPI
- CD90.2+ TCRβ+ CD4− CD8β+ TCRγδ− CD49f− NK1.1− B220− CD11b− CD11c− MHCII−, using a
Sony
MA900
cell sorter. All samples were pooled together, and approximately 15,000 sorted cells were loaded onto
(683)
Self-Assembling Allergen Vaccine Platform Raises Therapeutic Allergen-Specific IgG Responses without Induction of Systemic Allergic Responses
ACS biomaterials science & engineering
March 11, 2024
Cossette BJ, Shetty S, Issah LA, Collier JH.
Cells were washed, trypsinized, suspended in FACS buffer and DsRed+ cells were sorted using a
Sony
MA900
cytometer. The sorted cell population was diluted in RBL culture media to ~1 cell/100μL and plated in
(684)
MCL1 inhibition targets Myeloid Derived Suppressors Cells, promotes antitumor immunity and enhances the efficacy of immune checkpoint blockade
Cell Death Dis
March 8, 2024
Nabanita Mukherjee, Elizabeth Katsnelson, Tonya M. Brunetti, Kylie Michel, Kasey L. Couts, Karoline A. Lambert, William A. Robinson, Martin D. McCarter, David A. Norris, Richard P. Tobin,
et al.
(antibody information can be found in Supplementary Table 1)
myeloid cells
were sorted on the
Sony
MA900
cell sorter. Single cells were captured on the 10X Genomics Chromium system and libraries were prepared
(685)
PTEN loss in glioma cell lines leads to increased extracellular vesicles biogenesis and PD-L1 cargo in a PI3K-dependent manner
bioRxiv
March 2, 2024
Julio C. Sanchez, Timothy M. Pierpont, Dariana Argueta-Zamora, Kristin Wilson, Avery August, Richard A. Cerione
the resulting cell pellet was then resuspended in FACS buffer. Stained cells were sorted on a
Sony
MA900
with a 100 μm nozzle. Our gating strategy used empty vector
Jurkat cells
as a negative control for
PD-1
.
(686)
Generation of murine tumor models refractory to αPD-1/-L1 therapies due to defects in antigen processing/presentation or IFNγ signaling using CRISPR/Cas9
PLoS One
March 1, 2024
Paul L. Chariou, Christine M. Minnar, Mayank Tandon, Mary R. Guest, Raj Chari, Jeffrey Schlom, Sofia R. Gameiro
4 min, and resuspended in PBS. Successfully
transfected
cells were positively selected using a
SONY
MA900
cell sorter (Sony, San Jose, CA) based on their positive GFP expression, and individually seeded (single
(687)
A humanized IL-2 mutein expands Tregs and prolongs transplant survival in preclinical models
J Clin Invest
March 1, 2024
Orhan Efe, Rodrigo B. Gassen, Leela Morena, Yoshikazu Ganchiku, Ayman Al Jurdi, Isadora T. Lape, Pedro Ventura-Aguiar, Christian LeGuern, Joren C. Madsen, Zachary Shriver,
et al.
Yeasts
expressing high levels of IL-2 and/or reduced binding to CD122/CD132 were sorted using a
Sony
MA900
flow cytometer
. The IL2 gene sequences within the enriched libraries were
PCR
amplified and sequenced
(688)
Cell-type-specific CAG repeat expansions and toxicity of mutant Huntingtin in human striatum and cerebellum
Nature genetics
March 1, 2024
Mätlik K, Baffuto M, Kus L, Deshmukh AL, Davis DA, Paul MR, Carroll TS, Caron MC, Masson JY, Pearson CE,
et al
.
(PBS, 0.2% BSA, 40 U ml−1 RNasin ribonuclease inhibitor, 0.5 µg ml−1 DAPI) and separated with
SONY
MA900
Cell Sorter (software ver. 3.0.5). Aggregates of nuclei were excluded based on higher DAPI signal and
(689)
A humanized IL-2 mutein expands Tregs and prolongs transplant survival in preclinical models
Journal of Clinical Investigation
March 1, 2024
Orhan Efe, Rodrigo B. Gassen, Leela Morena, Yoshikazu Ganchiku, Ayman Al Jurdi, Isadora T. Lape, Pedro Ventura-Aguiar, Christian LeGuern, Joren C. Madsen, Zachary Shriver,
et al.
Yeasts
expressing high levels of IL-2 and/or reduced binding to CD122/CD132 were sorted using a
Sony
MA900
flow cytometer
. The IL2 gene sequences within the enriched libraries were
PCR
amplified and sequenced
(690)
Immunoengineering can overcome the glycocalyx armour of cancer cells
Nature Materials
March 1, 2024
Sangwoo Park, Marshall J. Colville, Justin H. Paek, Carolyn R. Shurer, Arun Singh, Erica J. Secor, Cooper J. Sailer, Ling-Ting Huang, Joe Chin-Hun Kuo, Marc C. Goudge,
et al.
cells with defined standardized gates for low, intermediate, and high Muc1 expression by FACS (
Sony
MA900
Cell Sorter). In place of PI, ZR-75-1 cells were labelled with Annexin V conjugated with CF647 (0.5
(691)
Immune-restoring CAR-T cells display antitumor activity and reverse immunosuppressive TME in a humanized ccRCC mouse model
iScience
February 16, 2024
Yufei Wang, Jae-Won Cho, Gabriella Kastrunes, Alicia Buck, Cecile Razimbaud, Aedin C. Culhane, Jiusong Sun, David A. Braun, Toni K. Choueiri, Catherine J. Wu,
et al.
(MOI 20) with 10 μg/mL Diethylaminoethyl (DEAE). The CAR positive
T cells
were sorted by
SONY
sorter
MA900
. After sorting, the
T cells
were cultured in RPMI-1640 medium supplemented with 10% FBS, IL-7 (5 ng/mL,
(692)
Ultrahigh frequencies of peripherally matured LGI1- and CASPR2-reactive B cells characterize the cerebrospinal fluid in autoimmune encephalitis
Proceedings of the National Academy of Sciences
February 13, 2024
Jakob Theorell, Ruby Harrison, Robyn Williams, Matthew I. J. Raybould, Meng Zhao, Hannah Fox, Andrew Fower, Georgina Miller, Zoe Wu, Eleanor Browne,
et al.
CD20, CD27, CD38, CD138, plus 7AAD as a live-dead cell marker. Single-
cell sorting
utilized a
Sony
MA900
within 1 h from CSF collection. Indexed fcs files were compensated with FlowJo (Ashland, OR: Becton,
(693)
Virus-derived circular RNAs populate hepatitis C virus–infected cells
Proceedings of the National Academy of Sciences
February 13, 2024
Qian M. Cao, Pakpoom Boonchuen, Tzu-Chun Chen, Shaohua Lei, Kunlaya Somboonwiwat, Peter Sarnow
FACS buffer (PBS containing 2% FBS). GFP
fluorescence
in each
transfection
was assessed with a
Sony
MA900 Multi-Application Cell Sorter
(Stanford). Generation of Mutant HCV JFH-1 DNA Infectious
Clones
Containing a HiBiT Tag Inserted in
(694)
A GPCR-neuropeptide axis dampens hyperactive neutrophils by promoting an alternative-like polarization during bacterial infection
Immunity
February 13, 2024
Naina Gour, Hwan Mee Yong, Aishwarya Magesh, Aishwarya Atakkatan, Felipe Andrade, Stephane Lajoie, Xinzhong Dong
al.83,https://bioconductor.org/packages/release/bioc/html/scDblFinder.html Other,Other,Other BD LSRII cell analyzer,BD Biosciences,N/A MoFlo XDP cell sorter,Beckman Coulter,N/A
MA900
cell sorter,
Sony
,N/A ABI StepOnePlus,ThermoFisher,N/A
(695)
Light controls mesophyll-specific post-transcriptional splicing of photoregulatory genes by AtPRMT5
Proceedings of the National Academy of Sciences
February 6, 2024
Yan Yan, Haofei Luo, Yuwei Qin, Tingting Yan, Jinbu Jia, Yifeng Hou, Zhijian Liu, Jixian Zhai, Yanping Long, Xian Deng,
et al.
For
cell sorting
, the nuclei suspension was stained with DAPI and loaded to a
flow cytometer
(
SONY
MA900
) equipped with a 100-μm nozzle. Approximately 100,000 nuclei were sorted for each sample based on DAPI
(696)
Mural cells interact with macrophages in the dura mater to regulate CNS immune surveillance
Journal of Experimental Medicine
February 5, 2024
Hyunjung Min, Shane M. O’Neil, Li Xu, E. Ashley Moseman, Joanne Kurtzberg, Anthony J. Filiano
using anti-CD44 and -CD62L antibodies and CD44−/CD62L+ naïve
helper T cells
were isolated using a
Sony
MA900
cell sorter. Cells were plated on a hamster IgG-precoated plate with anti-CD3 and anti-CD28 antibodies
(697)
Cytotoxic CD8+ Temra cells show loss of chromatin accessibility at genes associated with T cell activation
Frontiers in Immunology
February 2, 2024
Lehte Türk, Igor Filippov, Christian Arnold, Judith Zaugg, Liina Tserel, Kai Kisand, Pärt Peterson
7-AAD (Miltenyi Biotec) was added to the samples to exclude nonviable cells. Samples were sorted with
MA900 Multi-Application Cell Sorter
(
Sony Biotechnology
; gating strategy shown in Supplementary Figures S3 , S13A ) and were collected
(698)
Efficient prime editing in mouse brain, liver and heart with dual AAVs
Nature biotechnology
February 1, 2024
Davis JR, Banskota S, Levy JM, Newby GA, Wang X, Anzalone AV, Nelson AT, Chen PJ, Hennes AD, An M,
et al
.
nuclei were resuspended in 1–2 ml of NSB, passed through a 35-µm cell strainer and then sorted using a
MA900
Cell Sorter (
Sony Biotechnology
) at the Broad Institute
Flow Cytometry
Core. See Supplementary Fig.
(699)
Wnt signaling blockade is essential for maintaining the pluripotency of chicken embryonic stem cells
Poultry science
February 1, 2024
Kajihara R, Ezaki R, Ichikawa K, Watanabe T, Terada T, Matsuzaki M, Horiuchi H.
of SSEA-1-positive cells among the chESCs cultured under various conditions was determined using a
MA900
cell sorter (
Sony Biotechnology
, San Jose, CA). The chESCs were separated into single cells using TrypLE
(700)
LRP11 promotes stem-like T cells via MAPK13-mediated TCF1 phosphorylation, enhancing anti-PD1 immunotherapy
Journal for immunotherapy of cancer
January 25, 2024
Sun L, Ma Z, Zhao X, Tan X, Tu Y, Wang J, Chen L, Chen Z, Chen G, Lan P.
antibody (
134606
;
BioLegend
, USA) and APC-labeled anti-
PD1
antibody (
562671
;
BD Biosciences
, USA) by
SONY
MA900
multifunctional fully automated
flow cytometer
.
SLAMF6
+
PD1
+ CD8+ T cells were stained with CellTrace
Page
<<
<
31
32
33
34
35
>
>>
Reviews
Be the First to Write a Review!
MA900 Multi-Application Cell Sorter from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top