Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Spectral Flow Cytometers
ID7000™ Spectral Cell Analyzer
Supplier Images
Published Figures
ID7000™ Spectral Cell Analyzer
ID7000™ Spectral Cell Analyzer from Sony Corporation
Be the first to write a review!
Citations:
(429)
Figures:
(9)
Inquire
from
Sony Corporation for
ID7000™ Spectral Cell Analyzer
Description
The ID7000 high-parameter spectral analyzer / flow cytometer can be configured with up to 7 lasers and 186 detectors.
Product Specs
Citations
Reviews
Product Specs
Item
ID7000™ Spectral Cell Analyzer
Company
Sony Corporation
Price
Inquire
Catalog Number
ID7000
Excitation Lasers
320 nm, 355 nm, 405 nm, 488 nm, 561 nm, 637 nm, 808 nm
Detection
32-channels (PMT arrays); can be configured with 186 detectors to detect 44 colors or more
Sample Type
5-mL (12 x 75-mm) tubes, 96-well and 384-well plates (Autosampler)
Throughput
40,000 events per second
Lasers
3 to 7 lasers
Excitation Wavelength
320 nm, 355 nm, 405 nm, 488 nm, 561 nm, 637 nm, 808 nm
Measuring Range
186 fluorescence channels
Capacity
Tubes (5 mL), Microplates using autosampler (96-well, 384-well)
Data Analysis
40,000 events/sec
Dimensions
(WxDxH) 106 x 71.9 x 76 cm
Flow Rate
33 to 200 µL/min
Add to Compare List
Citations (429)
(1)
A macrophage-mimetic nanocarrier co-loaded with geraniol and FK13-a1 for MRSA-induced acute lung injury
Drug Deliv
December 31, 2026
Haonan Li, Binghong Xu, Junguang Liang, Tao Hu, Tingting Wu, Liqin Lai, Xuan Zou, Ziquan Lv, Xiangjie Yao, Xiaobao Jin,
et al.
CD4+ T cells, CD8+ T cells,
neutrophils
,
monocyte
/
macrophages
, and Tregs were detected using a
Sony
ID7000
flow cytometer
. 2.22. Statistical analysis All data are presented asmean ± standard deviation (SD)
(2)
Efficient inference of non-polyreactive antibody variants dependent on local fine-tuning
mAbs
December 31, 2026
Matthew Saunders, Sophie Comyn, Borka Medjo, Zahra Anderson, Chase LaCombe, Jake Ripley, Kyra Chapman, Tim Ma, Abigail Ventura, Alyssa Ruelos,
et al.
minutes, and washed once with ice‑cold PBS. Cell pellets were resuspended in 100 uL PBS and run on a
SONY
ID7000 spectral cell analyzer
. All experiments were performed in biological triplicate and 100,000 events were analyzed using FlowJo
(3)
Tolerogenic Programming Promotes Human Cytomegalovirus Permissiveness in Dendritic Cells
Eur J Immunol
October 28, 2026
Katharina Rahmel-Stein, Jennifer Becker, Berenike Lange, Luise Krajewski, Britta Eiz-Vesper, Ulrich Kalinke
cells were washed with
labeling
buffer and fixed with 1% paraformaldehyde. Data were acquired on the
ID7000 Spectral Cell Analyzer
(
SONY Biotechnology
) and analyzed using FlowJo (version 10.10.0). 3.6
Multiplex
Cytokine
Assay
IL‐10
(4)
Large Oncosomes Induce Pro-Metastatic Stromal-Myeloid Reprogramming
Adv Sci (Weinh)
October 25, 2026
Taylon Felipe Silva, Virginia Marcia Concato-Lopes, Fatima Bedier, Lauren Newman, Diana Kitka, Jamelle Brown, Blandine Victor, Minhyung Kim, Tatyana Vagner, Catherine Grasso,
et al.
1:200
), and BD Horizon Fixable Viability Stain 780 (
1:1000
) [51, 52, 53]. Samples were acquired on a
Sony
ID7000
spectral
flow cytometer
. Autofluorescence was defined using unstained controls and removed during spectral
(5)
Setup and Analysis of Human Tonsil and Adenoid-Based Immune Organoids for Studying T and B Cell-Mediated Adaptive Immunity
Curr Protoc
October 24, 2026
Maximilian Moll, Klaus W. Eichhorn, Thorsten Send, Dirk Baumjohann
pipette (Mettler Toledo, cat. no. 17011788)20‐µl pipette tips (Mettler Toledo, cat. no. 30389225)
Sony
ID7000
spectral analyzer (Sony Biotechnology) or similarSony
ID7000
analyzer software (Sony Biotechnology)
(6)
Synovial fluid cell isolation protocol affects immune cell recovery and composition across inflammatory states
RMD Open
October 23, 2026
Abel Mekonnen Tesfaye, Jara Tsegaye Leta, Danh Phung, Erlend Holm-Nordli, Julie Røkke Osen, Josefine Eilsø Nielsen, Hilde Berner Hammer, Andreas Lossius, Guro Løvik Goll, Silje Watterdal Syversen,
et al.
fluorescence-activated cell sorting
buffer (PBS/0.5% BSA/1 mM EDTA). Data acquisition was performed using a 5-laser
Sony
ID7000
spectral
flow cytometer
(Sony Biotechnology). Synovial fluid viscosity measurement Synovial fluid
(7)
Rational Tuning of Intracellular Release Kinetics in PROTAC–Peptide Conjugates via Positional Modulation of Functional Peptide Domains
ACS Bio & Med Chem Au
October 21, 2026
Maho Miyamoto, Atsuki Hirama, Kosuke Saito, Naoki Shida, Mahito Atobe, Hidetomo Yokoo, Yosuke Demizu
The mean
fluorescence
intensity in cells was measured using a
flow cytometer
(Spectral Cell Analyzer
ID7000
,
Sony
). The results are presented as the mean and standard deviation obtained from three samples. Because
(8)
Microbiota-regulated TCDCA associates with Parkinson's disease severity and promotes BBB dysfunction through VSMC TGR5 signaling in mice
Cell Rep Med
October 20, 2026
Zhe Zhao, Yixuan Liu, Wen Ma, Gaofei Hu, Jincen Hao, Chaobo Bai, Jing Chen, Qi Zhang, Huanhuan Cao, Xiaoyi Liu,
et al.
temperature according to the manufacturer’s instructions. Stained cells were analyzed using a
Sony
ID7000
flow cytometer
(Sony Biotechnology, Japan). Apoptotic populations were quantified, with Annexin V+/7-AAD-
(9)
A Confirmatory, Dual Center Nonhuman Primate Study on the Efficacy of Novel Oropharyngeal Spray Immunization With an Adenoviral Vector Vaccine Against RSV-Important Lessons Learned
J Med Primatol
October 20, 2026
Matthias Tenbusch, Gerrit Koopman, Petra Mooij, Berit Roshani, Pascal Irrgang, Dennis Lapuente, Ivanela Kondova, Willy M. Bogers, Edmond J. Remarque, Ramona Vestweber,
et al.
performed using spectral analyzers. At the BPRC the Cytek Aurora (Cytek, Fremont, CA, USA) and at DPZ the
ID7000
(
Sony Biotechnology
, San Jose, CA, USA) were used. Analysis was performed using FlowJo software (Version
(10)
Compartment-specific PPARδ activity controls the outcome of cancer-immune cell competition and immunotherapy efficacy
Nat Immunol
October 14, 2026
Paul Bunk, Ilgin Ergin, Timothy Maher, Vyom Shah, Julia R. Bonney, Lokesh B. S. S. Kumar, Charlie Chung, Nils Wellhausen, Philip Moresco, Sarah Shao,
et al.
(TMRE;
Thermo Fisher
,
T669
) in PBS 30 min at 37 °C. Samples were acquired on a BD Fortessa or
Sony
ID7000
and analyzed in FlowJo 10. Absolute
cell numbers
were calculated based on the acquired events and the
(11)
Basal Marker ΔNp63α Is Enriched in Pancreatic Cancer Metastases but Not in Primary Tumors Post-Chemotherapy
Cancer Med
October 14, 2026
Daniel H. Ryan, Yuuki Ohara, Michael J. Kruhlak, Xianyu Zhang, Miao Lin, Chin-Hsien Tai, Christine Alewine
antibodies used see Table S1. 2.4
Flow Cytometry
5 × 105 fixed cells per tube were analyzed using a
Sony
ID7000 Spectral Cell Analyzer
and results were visualized using FloJo. 2.5 Cell Viability Assays 5 × 103 cells/well were plated
(12)
Targeting CD28 on T lineage malignancies with chimeric antigen receptor T cells
Nat Commun
October 8, 2026
Semjon Willier, Julian Färber, Theodora Ispyrlidou, Jonas Wilhelm, Eileen Mayer, Dana Stenger, Jannika Seiferling, Annika E. Brien, Sophia Nikolaides, Paulina Ferrada-Ernst,
et al.
and on the
MACSQuant Analyzer
10 (
Miltenyi Biotec
). Spectral
flow cytometry
was performed using the
ID7000 Spectral Cell Analyzer
(
Sony Biotechnology
).
Flow cytometry
data was analyzed using FlowJo 10.10.0 (FlowJo LLC) and the
ID7000
(13)
CDK2/9 blockade remodels chromatin and drives phenotypic plasticity in glioblastoma organoids
Cell Commun Signal
October 2, 2026
Philipp Kaps, Anne Sophie Hieltscher, Andrea Auditore, Christoph Kamper, Sophie-Charlotte Nelz, Jacqueline Heskamp, Paul Meißner, Annabell Wolff, Katharina Richter, Jakob Brandstetter,
et al.
µg/ml, BD,
1:250
in filtered PBS, 30 min at room temperature). Measurements were performed using a
Sony
ID7000
flow cytometer
. Evs were defined based on their
fluorescence
(CellTrace), and expression of CD95 (Fas)
(14)
CAR T cell targeting of inflammatory myeloid progenitors in the bone marrow remodels border-associated macrophages and reverses cognitive aging
bioRxiv
September 30, 2026
Alexander S. Harris, James A. Rouse, Guangran Guo, Inés Fernandez-Maestre, Sujay Pal, Brian Oh, Shuxuan Li, Wen Yi See, Arianna Anderson, Joseph Gewolb,
et al.
analysis. Fixed samples were analyzed on either an
LSRFortessa
flow cytometer
(
BD Biosciences
) or an
ID7000 Spectral Cell Analyzer
(
Sony Biotechnology
). Live cells were analyzed and sorted using either a
BD FACSymphony S6 cell sorter
(15)
Association Between TLR9-Mediated Interferon-Alpha Production and Short-Term Risk of Common Cold: A Pilot Observational Study
Tropical Medicine and Infectious Disease
September 30, 2026
Yukiko Kato, Truong Tuyet Mai, Nghiem Nguyet Thu, Osamu Kanauchi, Yusuke Ushida
intracellular
staining
for IFN-α was performed. Cells were analyzed using the Spectral Cell Analyzer
ID7000
(
SONY
, Tokyo, Japan), followed by analysis using FlowJo software (version 10.6.0, BD Biosciences). Figure
(16)
Activation of conventional and plasmacytoid dendritic cells and enhancement of anti-viral immune responses by Lactobacillus delbrueckii subsp. bulgaricus OLL1073R-1 and Streptococcus thermophilus OLS3059
PLoS One
September 29, 2026
Hiroki Kono, Toshihiro Sashihara
(BD), anti-CD123 BV510 (BD), anti-CD304 PE (BD) after blocking and analyzed by Spectral Cell Analyzer
ID7000
(
Sony
, Tokyo, Japan). Statistical analysis All statistical analyses were performed by BellCurve for
(17)
Engineered Human Ferritin Nanocage Enhances Intracellular Vancomycin Delivery and Activity Against Gram-Positive Bacteria in Macrophages
Int J Nanomedicine
September 23, 2026
Binwang Cao, Manxian Wang, Tao Li, Deyu Li, Liangyan Zhang, Nianzhi Ning, Hui Wang
temperature in the dark, and resuspended in 1×
staining
buffer. Samples were analyzed using a
flow cytometer
(
ID7000
,
Sony
, Japan), and cellular uptake was evaluated according to AF647-positive cell percentage and mean
(18)
Efficient generation of human cDC1-like cells to detect and enhance tumor-reactive T cells via CD4+ T cell help
Cell Reports Methods
September 21, 2026
Yizhi Wang, Xin Lei, Tom de Wit, Ellen Schrama, Marij J.P. Welters, Karel van Leeuwen, Sander de Kivit, Miriam de Boer, Jitske van den Bulk, Noel F.C. C. de Miranda,
et al.
gating. Data acquisition was performed on BD LSR Fortessa™, Cytek Aurora spectral
flow cytometers
or
SONY
ID7000™ Spectral Cell Analyzer
and analyzed using FlowJo™ or OMIQ software. NanoString nCounter
gene expression analysis
Progenitor-derived
(19)
Effects of refined carbohydrates on immune markers after weight loss on a very-low-carbohydrate diet: A randomized controlled feeding trial
Cell Press Blue
September 21, 2026
Ezequiel Dantas, Yushu Shi, Jeshua Kim, Anirudh Murthy, Alexander Emmanuelli, Shiri Li, Tiffany Perrier, Tanvir Ahmed, Isaac Nathoo, Carolina E. Echeverria,
et al.
with distilled water as previously described.74 Samples were then acquired without fixation in a
SONY
ID7000 Spectral Cell Analyzer
. Unmixing was performed in the
ID7000
software and analysis in FlowJo (v.10.10).
Western Blot
Plasma
(20)
Targeting glial PD-1/PD-L1 restores microglial homeostasis and reduces neuronal hyperactivity in an Alzheimer's disease model
Sci Adv
September 18, 2026
Taeyoung Park, Leechung Chang, Seung Won Chung, Seowoo Lee, Sungjun Bae, Carlo Condello, Yong Ho Kim, Jaecheol Lee, Han-Joo Kim, Ho-Keun Kwon,
et al.
Invitrogen
). After
staining
, the cells were washed with PBS, and data acquisition was performed using a
Sony
ID7000
(Sony). For
cell sorting
, the isolated cells were stained with the following antibodies:
CD11b
-FITC
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
ID7000™ Spectral Cell Analyzer from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top