Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
ID7000™ Spectral Cell Analyzer
Supplier Images
Published Figures
ID7000™ Spectral Cell Analyzer
ID7000™ Spectral Cell Analyzer from Sony Corporation
Be the first to write a review!
Citations:
(429)
Figures:
(9)
Inquire
from
Sony Corporation for
ID7000™ Spectral Cell Analyzer
Description
The ID7000 high-parameter spectral analyzer / flow cytometer can be configured with up to 7 lasers and 186 detectors.
Product Specs
Citations
Reviews
Product Specs
Item
ID7000™ Spectral Cell Analyzer
Company
Sony Corporation
Price
Inquire
Catalog Number
ID7000
Detection
32-channels (PMT arrays); can be configured with 186 detectors to detect 44 colors or more
Throughput
40,000 events per second
Lasers
3 to 7 lasers
Excitation
320 nm, 355 nm, 405 nm, 488 nm, 561 nm, 637 nm, 808 nm
Parameters
186 fluorescence channels
Capacity
Tubes (5 mL), Microplates using autosampler (96-well, 384-well)
Data Throughput
40,000 events/sec
Dimensions
(WxDxH) 106 x 71.9 x 76 cm
Flow Rate
33 to 200 µL/min
Add to Compare List
Citations (429)
(261)
Extent of N-glycosylation of the metalloproteinase inhibitor and cytokine TIMP-1 determines pancreatic cancer cell proliferation and survival via CD63
Journal of Biological Chemistry
May 8, 2025
Daniel Häußler, Damjan Manevski, Julian Frädrich, Vanessa Brunner, Olga Prokopchuk, Alexander Sommer, Batu Toledo, Percy Knolle, Marc E. Martignoni, Helmut Friess,
et al.
anti-human CD63-PerCP-Cy5.5; cat#:
353020
,
Biolegend
) as described before (22, 31) and analyzed on the
ID7000
flow cytometer
(
Sony
). For the analysis of
TIMP-1
binding to
CD63
, single cells were gated from all
(262)
Targeting capacity, safety and efficacy of engineered extracellular vesicles delivered by transdermal microneedles to treat plasmacytoma in mice
Clin Transl Med
May 2, 2025
Yulin Cao, Xuan Hu, Di Wu, Yuxuan Jiang, Yali Yu, Shan Wang, Wenlan Chen, Yaoying Long, Liuyue Xu, Jiao Qu,
et al.
antibody (BD Biosciences) for 20 min. The cells were then washed and resuspended in 150 µL PBS. The
Sony
ID7000
instrument (Sony), NovoCyte D3000 FCM instrument (Aisen) and FlowJo software were used in this study. In
(263)
B cell–derived acetylcholine mitigates skin inflammation in mice through α9 nicotinic acetylcholine receptor–mediated signaling
Proceedings of the National Academy of Sciences
April 29, 2025
Erica Foffi, Francesco Rugolo, Nisha Ramamurthy, Jillian Haight, Simone Helke, Annick You-Ten, Chantal Tobin, Soode Moghadas Jafari, Andrew J. Elia, Thorsten Berger,
et al.
563557
),
CD3
eFluor450 (
ThermoFisher
,
48-0033-82
).
Flow cytometric
analyses were performed using the
SONY
ID7000 spectral cell analyzer
at the Princess Margaret Flow Facility. Immunohistological Analyses. Formalin-fixed samples in paraffin-embedded
(264)
Dietary targeting of TRPM8 rewires macrophage immunometabolism reducing colitis severity
Cell Death Dis
April 25, 2025
D. Cicia, F. Biscu, F A Iannotti, M. Miraglia, C. Ferrante, N. Iaccarino, S. Cadenas de Miguel, A. Chiavaroli, A. Schiano Moriello, P. De Cicco,
et al.
resuspended in FACS buffer (0.5% FBS and 2 mM EDTA in PBS).
Flow cytometry
analyses were performed on a
Sony
ID7000
spectral analyzer (Sony) and subsequently analyzed using FlowJo v.10.8.1.
T-cells
(
CD3
+CD4+/-CD8+/-),
(265)
IL-17A-producing NKp44(-) group 3 innate lymphoid cells accumulate in Familial Adenomatous Polyposis duodenal tissue
Nat Commun
April 25, 2025
Kim M. Kaiser, Jan Raabe, Michael ToVinh, Gudrun Hack, Sarah Ahmad, Niko Müller, Julia Cassella, Sofia I. Walravens, Paula Alfaro, Lauren Arias Garcia,
et al.
analyses of cells were performed using an LSR-Fortessa Cytometer (
BD
, Germany) and a spectral
Sony
ID7000
7-laser cytometer22. In brief, all antibodies were titrated, the panels were tested using FMO controls,
(266)
Ivosidenib enhances cisplatin sensitivity in ovarian cancer by reducing cancer cell stemness
Cancer Drug Resistance
April 24, 2025
Mengqing Chen, Lin Huang, Simei Zhao, Mengna Zhu, Si Sun, Wenhan Li, Jing Cai, Minggang Peng, Yiping Wen, Zehua Wang
Vazyme
) according to the manufacturer’s instructions.
Flow cytometry analysis
was performed using the
ID7000 Spectral Cell Analyzer
(
Sony Biotechnology
, USA). Data analysis was performed using FlowJo 10.8.1 software. Annexin V+/PI−
(267)
Synthetic microbial community improves chicken intestinal homeostasis and provokes anti-Salmonella immunity mediated by segmented filamentous bacteria
The ISME Journal
April 23, 2025
Meihong Zhang, Suxin Shi, Yimei Feng, Fengwenhui Zhang, Yuxuan Xiao, Xin Li, Xingliang Pan, Yuqing Feng, Dan Liu, Yuming Guo,
et al.
assays
are provided in Supplementary Materials. Cells were acquired with a spectral cell analyzer (
SONY
ID7000
), and analysis was performed using FlowJo software. RNA extraction and real-time
quantitative PCR
Total
(268)
Subnanomolar MAS-related G protein-coupled receptor-X2/B2 antagonists with efficacy in human mast cells and disease models
Signal Transduct Target Ther
April 21, 2025
Ghazl Al Hamwi, Mohamad Wessam Alnouri, Sven Verdonck, Piotr Leonczak, Shaswati Chaki, Stefan Frischbutter, Pavel Kolkhir, Michaela Matthey, Constantin Kopp, Marek Bednarski,
et al.
washed, and resuspended in 100 µL of PBS/BSA/EDTA prior to measurement. The cells were analyzed on a
SONY
ID7000 spectral cell analyzer
(Sony Biotechnology) and further analyzed by FlowJo software (FlowJo version 10.8.0; BD). For β-hexosaminidase
(269)
High-Efficiency Enrichment of Megakaryocytes and Identification of Micromegakaryocytes from Human Bone Marrow by Imaging Flow Cytometry
Cells
April 12, 2025
Maya Nautrup Pedersen, Trine Engelbrecht Hybel, Jens Haugbølle Bjerre, Anne Sofie Borg Hammer, Anja Bille Bohn, Marie Bill, Carina Agerbo Rosenberg, Maja Ludvigsen
using the ID7000TM Spectral Cell Analyser (SONY Biotechnologies, San Jose, CA, USA) and the associated
ID7000
Acquisition and Analysis Software (V2.0.2,
SONY
Biotechnologies) at the FACS Core Facility, AU, Denmark. Single-stained
(270)
Oxidative stress-mediated abnormal polarization of decidual macrophages promotes the occurrence of atonic postpartum hemorrhage
Redox Biology
April 1, 2025
Jiangxue Qu, Hai Jiang, Boyang Zhang, Huifeng Shi, Shuai Zeng, Wei Wang, Lian Chen, Yangyu Zhao
(Invitrogen, CAT: M36007, dilution:
1:2500
) and DCFH-DA (Solarbio, CAT: D6470, dilution:
1:500
). A
SONY
ID7000
full-spectrum
flow cytometer
was used to detect
fluorescence
. The
CD14
+
macrophages
from decidual samples
(271)
OMIP ‐ 111 : Immune‐Profiling of T Helper 1 (Th1), Th2, and Th17 Signatures in Murine Splenocytes by Targeting Intracellular Cytokines
Cytometry Part A
April 1, 2025
Soumik Barman, Aisling Kelly, Danica Dong, Arsh Patel, Michael J. Buonopane, Jake Gonzales, Ben Janoschek, Andrew Draghi, David J. Dowling
splenocytes in steady state along with stimulated conditions. Panel optimization was completed using a
Sony
ID7000
spectral
flow cytometer
. Fluorochromes selection, modifications, and protocol details are documented
(272)
Severe inflammation and lineage skewing are associated with poor engraftment of engineered hematopoietic stem cells in patients with sickle cell disease
Nat Commun
April 1, 2025
Steicy Sobrino, Laure Joseph, Elisa Magrin, Anne Chalumeau, Nicolas Hebert, Alice Corsia, Adeline Denis, Cécile Roudaut, Clotilde Aussel, Olivia Leblanc,
et al.
CD34+Lin-CD133-CD38+CD10-CD110+CD45RA-, BNKP: CD34+Lin-CD133-CD38+CD10+.
Staining
was analyzed with a Spectral
ID7000
(
Sony
Biotechnologies) cell analyzer. Analysis of Hb and RBC properties
High-performance liquid chromatography
(273)
Keratin-72 restricts HIV-1 infection in resting CD4+ T cells by sequestering capsids in intermediate filaments
Nat Commun
March 27, 2025
Yang He, Meng Xu, Jiayue Ouyang, Li Zhao, Tiankui Ma, Xiaowei Zhang, Ruolin Wang, Hong Shang, Guoxin Liang
KC57
clone
(BD Cytofix) according to the manufacturer’s instructions. Data were collected on a
SONY
ID7000
and analyzed using FlowJo. Cytotoxicity
assays
The culture supernatant of lentiviral-transduced or
(274)
Ectopic germinal centers in the nasal turbinates contribute to B cell immunity to intranasal viral infection and vaccination
Proceedings of the National Academy of Sciences
March 25, 2025
Romain Gailleton, Nimitha R. Mathew, Laura Reusch, Karin Schön, Lydia Scharf, Anneli Strömberg, Andrea Cvjetkovic, Luaay Aziz, Johan Hellgren, Ka-Wei Tang,
et al.
the following antibodies were used: Bcl6 (
clone
: FJK-16s;
Invitrogen
). All cells were acquired on the
ID7000
(
SONY
) and analyzed using FlowJo 10.8.1 software (BD). Immuno-
Histochemistry
. The upper part of the
(275)
MDA5 protein mediating persistent ER stress/unfolded protein response contributes to endothelial-mesenchymal-transition of lung microvascular endothelial cell in dermatomyositis
Cell Commun Signal
March 23, 2025
Li-Qin Zhao, Xue-Qing Yang, Qian Niu, Xiao Feng, He-De Zhang, Shu-Yi Ye, Li-Juan Jiang, Fan Yu, Hong Ye, Wan-Li Ma
were resuspended in PBS.
Flow cytometry
was performed on 5 lasers full spectrum
flow cytometer
(
Sony
,
ID7000
) and data were analyzed with FlowJo software (Tree Star). The following anti-
human
antibodies were obtained
(276)
Tebentafusp, a T cell engager, promotes macrophage reprogramming and in combination with IL-2 overcomes macrophage immunosuppression in cancer
Nat Commun
March 10, 2025
Esra Güç, Agatha Treveil, Emma Leach, Anna Broomfield, Antonio Camera, James Clubley, Paula Nieto Garcia, Anastasiya Kazachenka, Rahul Khanolkar, Luis Del Carpio,
et al.
(
BioLegend
). Samples were then acquired on a BD LSRFortessaTM X-20
flow cytometer
(BD Bioscience) or
ID7000
spectral analyzer (
Sony
). Data analysis was performed using FlowJo V10.7.1 (Tree Star Inc, USA). A full
(277)
Role of GPX3+ astrocytes in breast cancer brain metastasis activated by circulating tumor cell exosomes
NPJ Precis Oncol
March 7, 2025
Guanghui Huang, Gongwen Xu, Qianqian Cao, Sheng Li, Hao Li, Xiaonan Zhang, Xiaomei Li
flow cytometry analysis
was conducted using the FlowJo software on BD LSR Fortessa (BD Biosciences) and
SONY
ID7000
instruments. The cells were washed, fixed, and permeabilized to enable intracellular
staining
using
(278)
Manganese-Loaded pH-Responsive DNA Hydrogels Enable Tg-Guided Thyroid Tumor Targeted Magnetic Resonance Imaging
ACS Applied Materials & Interfaces
March 5, 2025
Qingyi Hu, Anwen Ren, Ximeng Zhang, Zimei Tang, Rong Wang, Dong-Yuan Wang, Tao Huang, Jie Liu, Jie Ming
spectra. The quantification of cellular uptake was obtained by full
spectrum analysis
flow cytometry
(
ID7000
Sony
, Japan). The MR imaging was performed on a 3.0 T
magnetic resonance
imaging system (Ingenia CX,
(279)
Ferroptosis enhances the therapeutic potential of oncolytic adenoviruses KD01 against cancer
Cancer Gene Therapy
March 3, 2025
Wenhuan Li, Teng Ji, Jiaqi Ye, Shengfeng Xiong, Yao Si, Xiaohui Sun, Fei Li, Zhoutong Dai
FITC Annexin V Apoptosis Detection Kit I
(
556547
;
BD Biosciences
, USA).
Flow cytometric analysis
was conducted using a
SONY
ID7000
flow cytometer
(Sony, Japan).
Transmission electron microscopy
assay
After experimental treatments,
(280)
RNase T2 deficiency promotes TLR13-dependent replenishment of tissue-protective Kupffer cells
J Exp Med
March 3, 2025
Ryota Sato, Kaiwen Liu, Takuma Shibata, Katsuaki Hoshino, Kiyoshi Yamaguchi, Toru Miyazaki, Ryosuke Hiranuma, Ryutaro Fukui, Yuji Motoi, Yuri Fukuda-Ohta,
et al.
for 30 min at 4°C and washed with True-Nuclear Perm Buffer. The stained cells were analyzed using an
ID7000 spectral cell analyzer
(
Sony Biotechnology
). All data were analyzed using FlowJo software (BD Biosciences). Phosphorylation
Page
<<
<
11
12
13
14
15
>
>>
Reviews
Be the First to Write a Review!
ID7000™ Spectral Cell Analyzer from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top