Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Cell Biology
A Guide to Immunohistochemistry
Histology Equipment
Electron Microscopy Sample Preparation
EM ICE High Pressure Freezer
Supplier Images
Published Figures
Leica EM ICE
Leica EM ICE
EM ICE High Pressure Freezer from Leica Microsystems
Be the first to write a review!
Citations:
(288)
Figures:
(3)
Get Pricing
Get Pricing from
Leica Microsystems for
EM ICE High Pressure Freezer
Request Demo
Description
High pressure system for freezing aqueous samples delivers optimal sample preservation. Offers the highest flexibility to meet multiple application demands.
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
EM ICE High Pressure Freezer
Company
Leica Microsystems
Price
Get Pricing
Get Quote for this Product
Catalog Number
EM ICE
Dimensions
(WxDxH) 116 x 79 x 128.5 cm
Quantity
EA
Type
High Pressure Freezer
Capacity
Hold up to 3 different specimens
Applications
Cryo-fixation of biological samples for electron microscopy ultrastructure preservation
Specifications/Features
Programmable sequential freezing of nine (3 × 3) samples
Automated LN2 re-filling of the sample storage dewar
Recovery time between freezing cycles is one minute
Retrofitable light stimulation and/or electrical stimulation mode
Add to Compare List
Leica Microsystems
10 Parkway North Blvd., Suite 300
Deerfield
,
Illinois
60015
United States
Phone
: 800 248 0123
Company Profile
Website:
www.leica-microsystems.com
Citations (288)
(1)
A versatile nanobody platform for live and super-resolution imaging of synaptic vesicle dynamics and plasticity in rodent and human neurons
J Nanobiotechnology
May 14, 2026
Rashi Goel, Kristina Jevdokimenko, Ronja Rehm, Jannik Hentze, Paola Agüi-Gonzalez, Momchil Ninov, Erik Maier, Yin Wu, Felix Lange, Agata Witkowska,
et al.
then underwent washing steps in prewarmed (37 °C) conditioned medium before rapid
cryofixation
via an
EM ICE high-pressure freezer
(
Leica
) and storage in liquid nitrogen. Semiautomated
freeze-substitution
was performed via an AFS2
(2)
In situ architecture of plasmodesmata in Physcomitrium patens resolved by cryo-electron tomography
Nat Plants
May 14, 2026
Marcel Dickmanns, Matthias Pöge, Peng Xu, Sven Gombos, Zoe K. Barr, Manuel Miras, Jürgen M. Plitzko, Rüdiger Simon, Waltraud X. Schulze, Wolf B. Frommer,
et al.
dissolved in H2O to a final concentration of 20% (w/v)) and immediately high-pressure frozen (
LEICA
EM ICE
, Leica Mikrosysteme GmbH). Gametophores were collected after four weeks by manually dissecting individual
(3)
Electron microscopy‐based three‐dimensional subcellular imaging of plant male gametophyte
Journal of Integrative Plant Biology
May 1, 2026
Zhiqi Liu, Zizhen Liang, Mengfei Liao, Yixin Huang, Rui Ma, Jiayang Gao, Weiqi Wang, Tao Ni, Philipp S. Erdmann, Liwen Jiang
grains Freshly collected
Arabidopsis
anthers of mixed developing stages were subjected to HPF (
Leica
EM ICE
) with 0.15 M sucrose as cryo‐protectant in type B aluminum HPF carrier (Leica #16770142), followed by
(4)
Built different: ER cisternae formed by the Arabidopsis Lunapark proteins differ in ultrastructure and affect ER –Golgi transport
New Phytologist
April 29, 2026
Charlotte Pain, Tatiana Spatola Rossi, Nadine Field, Carmen Mata, Alessia Candeo, Muhammad W. Ali, Flavia Moreira‐Leite, Stanley W. Botchway, Federica Brandizzi, Verena Kriechbaumer
Fluid AG). Fixation of tissue for the
electron tomography
of cisternae was performed using HPF in an
EM ICE
(
Leica Microsystems
, Wetzlar, Germany). Samples were then transferred to an
EM AFS2
freeze substitution
(5)
Diel remodeling and cellular integration of the nitroplast
bioRxiv
April 17, 2026
Ethan H Li, Tyler Coale, Gaëlle Toullec, Artur Czajkowski, Pierre Henri Jouneau, Tim M. Dederichs, Chandni Bhickta, Zachary Raymond, Kyoko Hagino, Vitor Hugo Balasco Serrão,
et al.
membrane
using a manual vacuum
filtration
unit, and allowed to sediment prior to high-pressure freezing (
EM-ICE
,
Leica Microsystems
). A 1.2 μl aliquot of the concentrated mix was transferred into a type A carrier
(6)
Large-scale endoplasmic reticulum membrane solidification spatially organises proteins under thermal or metabolic stress
bioRxiv
April 12, 2026
Paul M. Mueller, Melissa R. Mikolaj, Elmehdi Belbaraka, Finn Hartstein, Sophia Altinoluk, Bjoern Perder, Philipp Trnka, Robert-William Welke, Heike Naumann, Nina Taudien,
et al.
ethanol series, and embedded in the PolyBed® 812 resin (Polysciences). High pressure freezing (
Leica
EM ICE
) of cell monolayers on sapphire discs was followed by
freeze substitution
(Leica AFS2) in 1% (w/v) osmium
(7)
RNA promotes synapsin phase separation providing a platform for local translation
bioRxiv
April 11, 2026
Branislava Rankovic, Zachary M Geisterfer, Akshita Chhabra, Vladimir M Jovanovic, Ian Seim, Christian Hoffmann, Antonela Condric, Gerard Aguilar Aguilar Pérez, Rinse de Boer, Lars T. Hofstede,
et al.
PHEM buffer, which served as a cryoprotectant. Cells were cryo-fixed using a high-pressure freezer (
EM ICE
;
Leica
).
Freeze substitution
was performed in acetone supplemented with 0.2% uranyl acetate and 2% H₂O
(8)
Macrophage anti-bacterial activity is controlled by adenylate kinase 4-mediated mitochondrial DNA synthesis
J Exp Med
April 6, 2026
Wei-Yao Chin, Ching-Tung Wu, Gunn-Guang Liou, Si-Tse Jiang, Yi-Sheng Cheng, Jr-Shiuan Lin, Betty A. Wu-Hsieh, Shi-Chuen Miaw
after BMDMs were infected with
Listeria
for 24 h, cells were harvested, then were cryo-fixed by
Leica
EM ICE
, dehydrated in a series of cold methanol treatments, and infiltrated serially with solutions of embedding
(9)
SNX-mediated biogenesis of a plant-unique vesicle derived from the multivesicular body
Nature Communications
March 24, 2026
Yanbin Li, Ran Tao, Hai Zhang, Xiaokang Wen, Stephen King Pong Leung, Qing Qi, Xiaohui Zheng, Haoxuan Guo, Congxian Wu, Zhifei Fu,
et al.
5-day-old
Arabidopsis
root tips were excised and rapidly frozen using a high-pressure freezing apparatus (
EM ICE
,
Leica
). For ultrastructural analysis,
freeze substitution
was performed using 2% OsO₄ and 0.5% uranyl
(10)
A proof-of-concept study on high pressure freezing for cryopreservation
PNAS Nexus
March 20, 2026
Fang Song, Mayuko Sato, Yuya Toyama, Taiyo Ishikawa, Fumiya Tokito, Takeshi Katsuda, Kiminori Toyooka, Yasuyuki Sakai, Masaki Nishikawa
otherwise lead to damage or
artifacts
. We used an HPF device commonly employed for
cryofixation
, the
Leica
EM ICE
. After mounting the carrier onto the specimen holder, vitrification can be achieved with a one-click
(11)
Visualizing suborganellar lipid distribution using correlative light and electron microscopy
Nature Cell Biology
March 20, 2026
H. Mathilda Lennartz, Suman Khan, Weihua Leng, Kristin Böhlig, Gunar Fabig, Yannick Kieswald, Falk Elsner, Nadav Scher, Michaela Wilsch-Bräuninger, Ori Avinoam,
et al.
their respective dilutions. High-pressure freezing High-pressure freezing was performed using a
Leica
EM-ICE
(Leica Microsystems) or a Wohlwend Compact 03 (Wohlwend GmbH). Before high-pressure freezing, cells
(12)
Comparison of Crosslinking Reagents and Their Impacts on Bone Derived ECM Hydrogels
Advanced Healthcare Materials
March 19, 2026
Joshua N. Jones, I‐Ning Lee, Andreas Rialas, Simon C. Kellaway, Rabea Loczenski, Christopher Parmenter, Lisa J. White
with manual baseline corrections. 4.5.2
Electron microscopy
Samples were prepared using the
Leica
EM ICE high pressure freezer
(HPF) (Leica, Austria). Central sections of gel samples were removed with a 3 mm tissue punch and placed
(13)
An Advanced Mobile Laboratory to enable field-based microbial ecology and cell biology across scales
bioRxiv
March 16, 2026
N Leisch, S Baars, T Beavis, P Bertucci, C Bhickta, M Bonadonna, C M Brannon, L Burgués-Palau, P Cherek, F Chevalier,
et al.
sandwiched with the flat side of the type B aluminium carrier (Wohlwend) and high-pressure frozen with the
EM ICE
(
Leica Microsystems
). The samples were freeze-substituted at EMBL’s
Electron Microscopy
Core Facility
(14)
Novel PMVs/ZIP4/Zinc/Prelamin A Axis Promotes Nuclear Dysmorphism and Vascular Aging in Humans and Rodents Post-Injury: Effective Treatment With Platelet Membrane-Coated ZIF-8 Nanoparticles
Aging Cell
March 9, 2026
Tengzhi Ma, Han Bao, Zhijue Xu, He Ren, Wenhao Tian, Jiahe Chen, Zhongqian Liu, Xinwu Lu, Fan Lv, Qingping Yao,
et al.
ultramicrotomy
. For high‐pressure freezing‐based TEM preparation, VSMCs were cryo‐fixed using a
Leica
EM ICE high‐pressure freezer
(Leica Microsystems, Germany), ensuring millisecond vitrification and optimal preservation of ultrastructural
(15)
Structural and functional implications of phase separation of membrane protein LacY in Escherichia coli
Nature Communications
February 25, 2026
Dmitrii Linnik, Sumayra Sultanji, Jan A. Stevens, Gea K. Schuurman-Wolters, Rinse de Boer, Christiaan M. Punter, Siewert J. Marrink, Ivan Maslov, Bert Poolman
copper gold-plated type B (flat-surfaced) carrier (Leica).
Cells immobilized
by high-pressure freezing (
EM ICE
,
Leica
) were freeze-substituted in 1% (w/v) OsO4 plus 0.5% uranyl acetate in acetone with 5% water,
(16)
CLCC1 governs ER bilayer equilibration to maintain lipid homeostasis
Nature
February 25, 2026
Lingzhi Wu, Jianqin Wang, Yawei Wang, Junhan Yang, Yuanhang Yao, Yonglun Wang, Dong Huang, Yating Hu, Xinxuan Xu, Renqian Wang,
et al.
carrier. The assembly of the sandwich carrier was promptly inserted into the high-pressure cryostat (
Leica
EM ICE
) for vitrification. The vitrified sandwich assembly was then transferred to a liquid ethane and propane
(17)
Encephalopathy-linked UFM1 variants impede neuronal protein translation, development, and function
EMBO Molecular Medicine
February 23, 2026
Catarina Perdigão, Josefa Torres, Helge M Magnussen, Janina Koch, Elena Rudashevskaya, Frederieke Moschref, Maksims Fiosins, Fritz Benseler, Sally Wenger, Tanja Nilsson,
et al.
CaCl2, 140 mM NaCl, 2.4 mM KCl, 10 mM Glucose, 10 mM HEPES, pH 7.6) before rapid
cryofixation
using an
EM ICE high-pressure freezer
(
Leica
) and subsequent storage in liquid nitrogen. Semi-automated
freeze-substitution
was performed
(18)
Structural Insights into Cell Wall-Related Vesicle Secretion with Different Mechanisms
Plants (Basel)
February 22, 2026
Jiawen Yang, Sheng Chang, Linlin Li, Xiaoyu Ma, Hua Han, Zheng Liu, Jian Zhu
freeze substitution
.
Yeast
cell samples were cultured as previously described [44,45] and prepared using a
Leica
EM ICE
(Leica Microsystems, Wetzlar, Germany) high-pressure freezing and a
Leica
EM AFS2
freeze substitution
(19)
A Glucan Synthase-Remodeler Module Organizes Branched Glucan Assembly in the Fungal Cell Wall
bioRxiv
February 21, 2026
Alaina H. Willet, Anand Jacob, Lesley A. Turner, Abdulrahman Khalid A. Alsanad, Tuo Wang, Kathleen L. Gould
were loaded into 3 mm high-pressure freezer specimen carriers (Ted Pella) and vitrified using a
Leica
EM ICE high-pressure freezer
. Samples were freeze-substituted in 1.5% uranyl acetate in methanol at −90°C for 48 hours followed by
(20)
Unraveling design principles of protein landscapes in photosynthetic membranes in plant chloroplasts
Sci Adv
February 13, 2026
Ashraf Mohamed, Yuval Garty, Hui Min Olivia Oung, Sujith Puthiyaveetil, Kajwal K. Patra, Andrea Tagliabue, Steven Lenhert, Dana Charuvi, Reinat Nevo, Helmut Kirchhoff,
et al.
aluminum discs (Engineering Office M. Wohlwend, Switzerland). Samples were high-pressure frozen with
EM-ICE
(
Leica Microsystems
, Austria). Freeze fracture was conducted at −120°C using a BAF 060 (Leica Microsystems,
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
EM ICE High Pressure Freezer from Leica Microsystems
Get Pricing
Get Quote for this Product
Product Specs
Company Info
Citations
Reviews
Back To Top