Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Cell Biology
A Guide to Immunohistochemistry
Histology Equipment
Electron Microscopy Sample Preparation
EM ICE High Pressure Freezer
Supplier Images
Published Figures
Leica EM ICE
Leica EM ICE
EM ICE High Pressure Freezer from Leica Microsystems
Be the first to write a review!
Citations:
(263)
Figures:
(3)
Get Pricing
Get Pricing from
Leica Microsystems for
EM ICE High Pressure Freezer
Request Demo
Description
High pressure system for freezing aqueous samples delivers optimal sample preservation. Offers the highest flexibility to meet multiple application demands.
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
EM ICE High Pressure Freezer
Company
Leica Microsystems
Price
Get Pricing
Get Quote for this Product
Catalog Number
EM ICE
Quantity
EA
Type
High Pressure Freezer
Dimensions
(WxDxH) 116 x 79 x 128.5 cm
Capacity
Hold up to 3 different specimens
Applications
Cryo-fixation of biological samples for electron microscopy ultrastructure preservation
Specifications/Features
Programmable sequential freezing of nine (3 × 3) samples
Automated LN2 re-filling of the sample storage dewar
Recovery time between freezing cycles is one minute
Retrofitable light stimulation and/or electrical stimulation mode
Add to Compare List
Leica Microsystems
10 Parkway North Blvd., Suite 300
Deerfield
,
Illinois
60015
United States
Phone
: 800 248 0123
Company Profile
Website:
www.leica-microsystems.com
Citations (263)
(1)
Large-scale endoplasmic reticulum membrane solidification spatially organises proteins under thermal or metabolic stress
bioRxiv
April 12, 2026
Paul M. Mueller, Melissa R. Mikolaj, Elmehdi Belbaraka, Finn Hartstein, Sophia Altinoluk, Bjoern Perder, Philipp Trnka, Robert-William Welke, Heike Naumann, Nina Taudien,
et al.
ethanol series, and embedded in the PolyBed® 812 resin (Polysciences). High pressure freezing (
Leica
EM ICE
) of cell monolayers on sapphire discs was followed by
freeze substitution
(Leica AFS2) in 1% (w/v) osmium
(2)
Macrophage anti-bacterial activity is controlled by adenylate kinase 4-mediated mitochondrial DNA synthesis
J Exp Med
April 6, 2026
Wei-Yao Chin, Ching-Tung Wu, Gunn-Guang Liou, Si-Tse Jiang, Yi-Sheng Cheng, Jr-Shiuan Lin, Betty A. Wu-Hsieh, Shi-Chuen Miaw
after BMDMs were infected with
Listeria
for 24 h, cells were harvested, then were cryo-fixed by
Leica
EM ICE
, dehydrated in a series of cold methanol treatments, and infiltrated serially with solutions of embedding
(3)
Visualizing suborganellar lipid distribution using correlative light and electron microscopy
Nature Cell Biology
March 20, 2026
H. Mathilda Lennartz, Suman Khan, Weihua Leng, Kristin Böhlig, Gunar Fabig, Yannick Kieswald, Falk Elsner, Nadav Scher, Michaela Wilsch-Bräuninger, Ori Avinoam,
et al.
their respective dilutions. High-pressure freezing High-pressure freezing was performed using a
Leica
EM-ICE
(Leica Microsystems) or a Wohlwend Compact 03 (Wohlwend GmbH). Before high-pressure freezing, cells
(4)
A proof-of-concept study on high pressure freezing for cryopreservation
PNAS Nexus
March 20, 2026
Fang Song, Mayuko Sato, Yuya Toyama, Taiyo Ishikawa, Fumiya Tokito, Takeshi Katsuda, Kiminori Toyooka, Yasuyuki Sakai, Masaki Nishikawa
otherwise lead to damage or
artifacts
. We used an HPF device commonly employed for
cryofixation
, the
Leica
EM ICE
. After mounting the carrier onto the specimen holder, vitrification can be achieved with a one-click
(5)
Comparison of Crosslinking Reagents and Their Impacts on Bone Derived ECM Hydrogels
Advanced Healthcare Materials
March 19, 2026
Joshua N. Jones, I‐Ning Lee, Andreas Rialas, Simon C. Kellaway, Rabea Loczenski, Christopher Parmenter, Lisa J. White
with manual baseline corrections. 4.5.2
Electron microscopy
Samples were prepared using the
Leica
EM ICE high pressure freezer
(HPF) (Leica, Austria). Central sections of gel samples were removed with a 3 mm tissue punch and placed
(6)
An Advanced Mobile Laboratory to enable field-based microbial ecology and cell biology across scales
bioRxiv
March 16, 2026
N Leisch, S Baars, T Beavis, P Bertucci, C Bhickta, M Bonadonna, C M Brannon, L Burgués-Palau, P Cherek, F Chevalier,
et al.
sandwiched with the flat side of the type B aluminium carrier (Wohlwend) and high-pressure frozen with the
EM ICE
(
Leica Microsystems
). The samples were freeze-substituted at EMBL’s
Electron Microscopy
Core Facility
(7)
Novel PMVs/ZIP4/Zinc/Prelamin A Axis Promotes Nuclear Dysmorphism and Vascular Aging in Humans and Rodents Post-Injury: Effective Treatment With Platelet Membrane-Coated ZIF-8 Nanoparticles
Aging Cell
March 9, 2026
Tengzhi Ma, Han Bao, Zhijue Xu, He Ren, Wenhao Tian, Jiahe Chen, Zhongqian Liu, Xinwu Lu, Fan Lv, Qingping Yao,
et al.
ultramicrotomy
. For high‐pressure freezing‐based TEM preparation, VSMCs were cryo‐fixed using a
Leica
EM ICE high‐pressure freezer
(Leica Microsystems, Germany), ensuring millisecond vitrification and optimal preservation of ultrastructural
(8)
CLCC1 governs ER bilayer equilibration to maintain lipid homeostasis
Nature
February 25, 2026
Lingzhi Wu, Jianqin Wang, Yawei Wang, Junhan Yang, Yuanhang Yao, Yonglun Wang, Dong Huang, Yating Hu, Xinxuan Xu, Renqian Wang,
et al.
carrier. The assembly of the sandwich carrier was promptly inserted into the high-pressure cryostat (
Leica
EM ICE
) for vitrification. The vitrified sandwich assembly was then transferred to a liquid ethane and propane
(9)
Structural and functional implications of phase separation of membrane protein LacY in Escherichia coli
Nature Communications
February 25, 2026
Dmitrii Linnik, Sumayra Sultanji, Jan A. Stevens, Gea K. Schuurman-Wolters, Rinse de Boer, Christiaan M. Punter, Siewert J. Marrink, Ivan Maslov, Bert Poolman
copper gold-plated type B (flat-surfaced) carrier (Leica).
Cells immobilized
by high-pressure freezing (
EM ICE
,
Leica
) were freeze-substituted in 1% (w/v) OsO4 plus 0.5% uranyl acetate in acetone with 5% water,
(10)
Encephalopathy-linked UFM1 variants impede neuronal protein translation, development, and function
EMBO Molecular Medicine
February 23, 2026
Catarina Perdigão, Josefa Torres, Helge M Magnussen, Janina Koch, Elena Rudashevskaya, Frederieke Moschref, Maksims Fiosins, Fritz Benseler, Sally Wenger, Tanja Nilsson,
et al.
CaCl2, 140 mM NaCl, 2.4 mM KCl, 10 mM Glucose, 10 mM HEPES, pH 7.6) before rapid
cryofixation
using an
EM ICE high-pressure freezer
(
Leica
) and subsequent storage in liquid nitrogen. Semi-automated
freeze-substitution
was performed
(11)
Structural Insights into Cell Wall-Related Vesicle Secretion with Different Mechanisms
Plants (Basel)
February 22, 2026
Jiawen Yang, Sheng Chang, Linlin Li, Xiaoyu Ma, Hua Han, Zheng Liu, Jian Zhu
freeze substitution
.
Yeast
cell samples were cultured as previously described [44,45] and prepared using a
Leica
EM ICE
(Leica Microsystems, Wetzlar, Germany) high-pressure freezing and a
Leica
EM AFS2
freeze substitution
(12)
A Glucan Synthase-Remodeler Module Organizes Branched Glucan Assembly in the Fungal Cell Wall
bioRxiv
February 21, 2026
Alaina H. Willet, Anand Jacob, Lesley A. Turner, Abdulrahman Khalid A. Alsanad, Tuo Wang, Kathleen L. Gould
were loaded into 3 mm high-pressure freezer specimen carriers (Ted Pella) and vitrified using a
Leica
EM ICE high-pressure freezer
. Samples were freeze-substituted in 1.5% uranyl acetate in methanol at −90°C for 48 hours followed by
(13)
Unraveling design principles of protein landscapes in photosynthetic membranes in plant chloroplasts
Sci Adv
February 13, 2026
Ashraf Mohamed, Yuval Garty, Hui Min Olivia Oung, Sujith Puthiyaveetil, Kajwal K. Patra, Andrea Tagliabue, Steven Lenhert, Dana Charuvi, Reinat Nevo, Helmut Kirchhoff,
et al.
aluminum discs (Engineering Office M. Wohlwend, Switzerland). Samples were high-pressure frozen with
EM-ICE
(
Leica Microsystems
, Austria). Freeze fracture was conducted at −120°C using a BAF 060 (Leica Microsystems,
(14)
Gene expression analysis reveals distinct PHB depolymerization mechanisms and broader involvement of the PHB cycle in Rhodospirillum rubrum growing on acetate and fructose
Microbial Cell Factories
February 9, 2026
Hugo Fleuriot-Blitman, Katerina Sabatova, Véronique Amstutz, Marketa Jakubickova, Eva Slaninova, Katerina Mrazova, María Celeste Ferrín Mendoza, Kamila Hrubanova, Vladislav Krzyzanek, Stanislav Obruca,
et al.
chloroform, and covered with the flat side of type B carriers. Samples were rapidly vitrified in the
EM ICE high-pressure freezer
(
Leica Microsystems
, Austria). Frozen carriers were transferred under liquid nitrogen into a
freeze-substitution
(15)
Ultrastructural membrane dynamics of mouse and human cortical synapses
Neuron
February 4, 2026
Chelsy R. Eddings, Minghua Fan, Yuuta Imoto, Kie Itoh, Xiomara McDonald, Jens Eilers, William S. Anderson, Paul F. Worley, Kristina Lippmann, David W. Nauen,
et al.
Arrow indicates vibratome cut direction.(B) A zap board enabling
electrical stimulation
in the
Leica
EM ICE high-pressure freezer
.(C) Overlay image of a 6 mm wide rubber O-ring, two sapphire disks and a Mylar spacer ring in between
(16)
ER remodelling is a feature of ageing and depends on ER-phagy
Nature Cell Biology
February 2, 2026
Eric K. F. Donahue, Nathaniel L. Hepowit, Elizabeth M. Ruark, Alexandra G. Mulligan, Brennen Keuchel, Nicholas D. Urban, Li Peng, Stedman Stephens, Derek J. Johnson, Natalie S. Wallace,
et al.
the flat side of B-type carrier (Leica) and vitrified using a high-pressure freezing machine (
Leica
EM ICE
). The frozen specimens were stored in liquid nitrogen until further processing with a modified
freeze-substitution
(17)
Energy metabolism and adaptation to hypoxia in the non-photosynthetic green alga Leontynka
BMC Biology
January 29, 2026
Pia Corre, Jana Pilátová, Tomáš Bílý, Eliška Zadrobílková, Ivan Čepička, Marie Vancová, Martin Lohr, Oliver D. Caspari, Marek Eliáš, Tomáš Pánek
resulting from thermal isomerization.
Electron microscopy
Pelleted cells were high-pressure frozen (
EM ICE
,
Leica
) in the presence of 20% BSA and were freeze-substituted in 2% OsO4 in 100% acetone for 96 h at
(18)
PAC regulates endo-, and exocytosis, and lysosomal-mitochondrial stress signaling in human mast cells
Cell Communication and Signaling
January 20, 2026
Korollus Melek, Philip Steiner, Sven Kappel, Benjamin Gottschalk, Ancuela Andosch, Michelle Duggan, Wolfgang F. Graier, Susanna Zierler, Christine Peinelt
Microsystems, Vienna, Austria) for high-pressure freeze fixation (HPF). HPF was performed using a
Leica
EM ICE
device (Leica Microsystems, Vienna, Austria) to achieve a cooling rate of at least 17,500 °C per second
(19)
Structural and Functional Characterization of EXPO‐Derived Extracellular Vesicles in Plants
Advanced Science
January 12, 2026
Jiayang Gao, Yanbin Li, Shengqi Zhang, Yilin He, Zhiqi Liu, Juan Wang, Jingmin Hua, Jinyu Chen, Junru Zhong, Huan Zhong,
et al.
and leaves from 5‐day‐old
Arabidopsis
seedlings
were harvested, cut, and rapidly frozen using a
Leica
EM ICE High‐Pressure Freezer
then transferred to the Leica AFS system. The samples are submerged in acetone with 0.25% glutaraldehyde
(20)
Correlating Molecular and Textural Properties of Raw Soy‐Based and Beef Burgers Using TD‐NMR and TPA
Journal of Food Science
January 9, 2026
Moshe Hai Azachi, Zeev Wiesman
cryo‐immobilized between two aluminum discs (3 mm diameter, 200 µm thick each) using a high‐pressure freezer (
EM ICE
,
Leica
). Sample preparation and imaging followed this workflow: Transferred under liquid nitrogen to
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
EM ICE High Pressure Freezer from Leica Microsystems
Get Pricing
Get Quote for this Product
Product Specs
Company Info
Citations
Reviews
Back To Top