Versatile Microplate Reader for Routine Cell-Based Assays

Cell & Tissue Engineering, Imec
Research Scientist

Overall

Performance

Ease-of-Optimization

What do these ratings mean?
Write a Review

Company:

Tecan

Product Name:

Infinite 200Pro - M Plex

We use the Tecan Infinite M Plex (Tecan i-control , 2.0.10.0) on a regular basis for a wide range of fluorescence and absorbance assays, particularly in the context of cell-based experiments. The instrument is routinely used for ELISA and absorbance-based assays, as well as for fluorescence measurements using fluorescent probes and markers. Its versatility allowed us to perform different types of plate-based assays on a consistent basis, making it a useful instrument for our day-to-day experimental workflow.

Experimental Design and Results Summary

Performance, Range, and Accuracy

The instrument delivered reproducible fluorescence measurements across a broad dynamic range, detecting signals from low-background controls (~100-500 RFU) up to highly fluorescent samples exceeding 40,000 RFU without saturation. For example, it resolved serial dilutions of Lucifer Yellow and 70 kDa dextran tracers, providing accurate quantification of permeability and barrier integrity endpoints with low well-to-well variability (example1 of triplicates: 507-532-577; example 2: 492-496-497).

Throughput, Workflow Efficiency, and Automation

The instrument enables rapid analysis of fluorescence-based assays in 384-well plate formats, with complete plate reads performed in under one minute and minimal hands-on intervention.

Sample Integrity and Consumable Requirements

Sample integrity is preserved as measurements are non-destructive and require no direct contact with the sample. Consumable requirements are limited primarily to compatible microplates and assay-specific reagents, resulting in relatively low ongoing operating costs compared with more complex analytical platforms.

Footprint, Facilities, and Daily Maintenance

The instrument has a moderate benchtop footprint and requires only standard laboratory infrastructure, including a stable power supply and a clean, temperature-controlled environment. Routine maintenance is minimal and consists mainly of periodic cleaning, calibration verification, and performance checks.

Connectivity, Data Output, and Software Compliance

Copilot said: The instrument software we used is not the most up-to-date version currently available; however, it fully supports our routine workflows. Data export and handling are straightforward, and the user interface is easy to navigate. Despite the older software version, we have not encountered significant limitations affecting data quality, instrument performance, or day-to-day laboratory operations.

Image Gallery

Summary

The Good

Reliable, sensitive fluorescence detection with a wide dynamic range, rapid plate reading, and straightforward operation. Customer assistance is also good.

The Bad

none

The Bottom Line

Versatile plate reader for routine applications.