Human CD4+ T Cell Isolation Kit from Freshly Isolated PBMC

VIB
Senior Research Associate Translational Research - VIB Discovery Sciences

Overall

Quality of Results

Ease-of-Optimization

What do these ratings mean?
Write a Review
Questions/Comments

Company:

Miltenyi

Product Name:

Human CD4+ T cell Isolation kit

Catalog Number:

130-096-533

We use the kit to isolate CD4+ T cells from freshly isolated PBMC. The kit allows to negative select and isolate the CD4+ T cells, therefore there is no chance of activating the cells.

Experimental Design and Results Summary

Application

T cell isolation

Starting Material

PBMC

Tips

Increase 20% the reagents and double incubation times to make sure the sample is pure.

Results Summary

The kit helped us isolate CD4+ T cells from PBMC (from buffy coats), with high purity (90%). Because there's high variation of the cells from donor to donor, we increased the reagents 20% and double the incubation times to make sure we have a better isolation of CD4+ T cells.

Image Gallery

Summary

The Good

Reliable; Easy to use; Protocol is simple and straightforward.

The Bad

In some cases, may need to increase the reagents and incubation times.

The Bottom Line

The kit is very easy to use; the protocol provided is simple and easy to follow