Thermo Fisher Scientific
CD127 PE-Cy5
15-1271-83
A7R34
Info:Supplier Page View Product Specs
Browse Similar Products: Cy5 Antibodies
I used this antibody to analyze T cell differentiation in a panel which also B cells, monocytes, DCs and NK cells in C57BL/6 mice infected with Plasmodium berghei ANKA, the murine model for malaria, in different organs.
Flow Cytometry
C57BL/6 splenocytes
1:100, 20 min, 4°C, in 50ul, in the dark
Fc Block
Fix/Perm buffer, 20 min, 4°C, in 70ul, in the dark,
20 min, 4°C, in the dark, in 50µl Perm/wash
Flow cytometry
I am here reviewing the a-CD127 antibody in PE-Cy5, which worked well for my experiments. I used this antibody to characrterize T cell differentiation beyond CD44/ CD62L. I was able to detect a distinct CD127+ population (rather than a “smear”) when using this antibody. Of note, I also tested this clone conjugated to PerCP-eFluor710; between that and the PE-Cy5 conjugate, I would advice to use CD127 PE-Cy5. CD127 expression is difficult to detect and PerCP-eF710 is not bright to achieve sufficient separation, at least not with my staining protocol. Perhaps, a longer incubation time would be beneficial. With that said, I was very happy with the PE-Cy5 conjugate. PE-Cy5 may induce spillover into other channels (for example APC), but paired with the fact that CD127 is not expressed at high levels, the actual spillover was not a concern to me. At a concentration of 1:100, the price for this antibody (and the expected yield from one tube) is also fair and economical. In the following, you will find my staining protocol in short. Incubation steps were performed at 4°C in the dark. 1.Count and adjust splenocytes to 1.5E6 cells, plate in a 96-well plate. 2.If required, stain cells with viability dye. Wash. 3. Stain with extracellular master mix for 20 min. Wash 2x. 4. Fixate/ Permeabilize with buffer of choice, depending on application. I used ThermoFisher FoxP3 fixation/permeabilization kit for 20 min. Wash with perm/ Wash 2x. 5. Perform intracellular staining for 20 min. Wash 2x. 6. Resuspend in FACS buffer and acquire as soon as possible. Here, data was acquired on a 5L Cytek Aurora.
N/A
PE-Cy5 worked great for this clone...
But dimmer fluorochromes might not yield sufficient separation.
This antibody worked great; choose the right fluorochrome to generate good data.