Biolegend
anti-CD4 PE/Cy7
344611
SK3
Info: Supplier Page View Product Specs
Browse Similar Products: Anti-CD4 Antibodies
This antibody was used to stain for helper T cells in human peripheral blood. It was chosen because it is a commonly used clone for CD4, PE/Cy7 is bright and works well with other fluorophores in the staining panel, and Biolegend has a good reputation for making quality flow cytometry antibodies.
Flow Cytometry
Whole blood
5 ul per test in 100uL staining volume for 15 minutes at room temperature
FcBlock + 0.2% BSA
N/A
LSR II
CD4 staining was excellent. Positive cells were fully resolved from negative.
Works well. Reproducible results.
Will continue to use this antibody.