ThermoFisher eBioscience
CD4 Monoclonal Antibody- Super Bright 436
62-0042-82
RM4-5
Info: Supplier Page View Product Specs View Product
Browse Similar Products: CD4 Flow Cytometry Antibodies
As an immunologist studying T cells, this flow antibody is reliable to identify CD4 T cells in our flow cytometry experiments.
Flow Cytometry
Tumor lymphocytes
1:400
FC Block in FACS buffer during surface staining
NA
Cytek Aurora (3 laser, BVR)
Tumor infiltrating CD4 T cells are strongly identified with this CD4 SuperBright 436 antibody, and fits in the panel nicely.
Titrate antibody based on samples
Robustly identifies CD4 T cells in the tumor.
None really.
Highly recommend this antibody if using the cytek aurora as it falls in a unique channel.