Browse Similar Products: GATA3 Flow Cytometry Antibodies
I use this GATA3 antibody to test the efficiency of embryonic stem cell differentiation to trophoblast cells.
Flow Cytometry
H9 cell line
1:50, room temperature, 45 minutes
FACS buffer
None
Fluorescence
GATA3 worked well as a marker for trophoblast as shown by the flow cytometry result using this antibody.
N/A
Strong and specific signal