Upstate's Beadlyte Human/Mouse Cytokine Detection Kits

BlueskyReddit
Upstate's Beadlyte Human/Mouse Cytokine Detection Kits
Several multiplexing technologies have emerged that allow for the simultaneous measurement of many soluble analytes from the same sample. This area is most prevalent in the field of immunology, where multiplexed cytokine detection kits enable high sensitivity of detection of multiple cytokines in small sample volumes. This is often beneficial in cases where the sample is a limiting factor (e.g. patient samples, transgenic animal samples, or other bodily fluids such as tear drops and breast milk).

Upstate’s Beadlyte Kits are designed to be used on the Luminex platform. Luminex corporation has a developed a sensitive assay system based on fluorescently encoded microspheres and reporter molecules that can detect multiple soluble agents from the same assay well. Luminex calls this their xMAP technology and it basically works by having up to 100 tiny beads that are resolved on their unique fluorescent spectra. So each bead has a unique tag that can be read by laser excitation. Each bead can be coated with a reagent for a bioassay, for example an antibody, to capture specific analytes from a given solution. A reporter dye, (another antibody labeled with a fluorescent reporter) then binds the captured analyte, in a manner that is very analogous to the “sandwich” based ELISAs except that it’s taking place on a bead. As the bead passes through the fluidics of the machine, one laser excites the bead to identify it, and another laser excites the fluorescent tag to quantify the amount of the analyte.

It’s on this platform that Upstate provides various kits to detect multiple cytokines for both the mouse and the human. The current maximum is 22 cytokines with the human system and 15 cytokines with the mouse system. In addition, there are several assays for detecting growth factors for both human and mouse. Each kit is designed for 100 assays, so basically it’s perfect for 96-well style experiments. There are pre-configured kits for the top 5, 10, 15, or 22 cytokines, or if you prefer you can customize to only include specific cytokines of interest. The assay format has been simplified to the point that it is straightforward even for the most inexperienced users of capture based assays. In comparing the cost of the kits to the equivalent amount of ELISAs needed for similar detection, you save a bundle.

Some of the benefits of the system are that Upstate provides internal calibration controls as well as recombinant standards for curve fit analysis. They also include extensive on-site training and set up, very helpful technical support, and knowledgeable field representatives. The machine itself takes up a small footprint, and has an automated plate assay holding platform, so you basically set it up, place your assay plate in, and start collecting. Complete walk-away operations. Depending on the stringency of required events, the machine reads the plate in at least an hour, with maximum stringency taking about 3 hours. The system also has an automated sheet delivery system which is very convenient. You just make sure you have reservoir buffer (purchased from Luminex) and empty the waste, and you’re good to go. Once collected, the data is saved in an Excel file, which is then analyzed according to the user. Although Upstate provides various different flavors of the beadlyte kits that include detecting phosphorylated signal molecules, kinase activity assays, and isotyping kits, our lab mainly uses it for human and mouse cytokine profiling.

Omar Perez, Ph.D.
Post-Doctoral Fellow
Nolan Lab
Department of Microbiology & Immunology
Center for Clinical Science Research
Stanford University

  • <<
  • >>
Upstate's Beadlyte Human/Mouse Cytokine Detection Kits
The Good

Multiplexed technology that detects multiple analytes from small sample volumes. Easy set up.

The Bad

Requires the purchase of the Luminex system as it is not compatible with other microfluidic or flow cytometric technologies.

The Bottom Line

This multiplex approach saves considerable time and costs