My plan is to develop western blots for detecting specific proteins after running SDS PAGE where I use HRP-tagged secondary antibodies. To detect these proteins, I use this chemiluminescent substrate.

Experimental Design and Results Summary

Application

To detect protein bands that are bound to HRP tagged antibodies.

Starting Material

Purified protein and HRP-tagged antibodies.

Tips

Incubate atleast for 3-5mins after adding the substrate for better detection

Results Summary

Excellent quality bands detected on the blot after 5 mins of incubation with substrate. I only used 1.5 ml of each solution A and B provided with the reagent kit for one blot and still worked perfect

DOI or PMID #

N/A

Image Gallery

Summary

The Good

Fast reaction and quick incubation time

The Bad

None

The Bottom Line

Excellent reagent and the intensity lasts for longer time. Specific to HRP tagged antibodies . Highly recommended.