Biolegend
Anti-human CD73 PerCP/Cy5.5
344013
Info: View Product View Product Specs
Browse Similar Products: CD73 Flow Cytometry Antibodies
This antibody was used to phenotype human bone marrow derived mesenchymal stem/stromal cells expanded two passages. This antibody was chosen because it is a commonly used clone for CD73, PerCP/Cy5.5 works well with other fluorochromes in the staining panel, and Biolegend had the best price.
Flow Cytometry
Human MSC
5uL per test in 100uL total staining volume for 20 minutes at room temperature
2% FBS
n/a
All cells were positive for CD73, as expected. Positive cells were strongly stained compared to unstained cells, and would be fully resolved from negative.
None
Works well. Low cost
Will continue to use this antibody in this panel.