Anti-Mouse IL-6

Medicine
Harvard Medical School
Post-doctoral fellow

Overall

Quality of Results

Ease-of-Optimization

What do these ratings mean?
Write a Review

Company:

eBioscience

Product Name:

Anti-Mouse IL-6 PE

Catalog Number:

12-7061-82

I studied immune response in mice against mycobacterium tuberculosis H37Rv and clearance of the pathogen from mice's systems using anti-mycobacterial ESAT6 binding peptides.

Experimental Design and Results Summary

Applications

Flow Cytometry

Sample

Murine Lymphocytes

Primary Incubation

1 hour on ice with primary antibodies

Blocking Agent

Blocking with 2% BSA and Fc block (1:100)

Secondary Incubation

1:50 dilution on ice with intracellular staining antibodies

Tertiary Incubation

None

Detection

FACS

Results Summary

Used to detect IL-6 expression on various sub-populations of murine lymphocytes upon mycobacterial infection in presence of ESAT6 binding peptide.

Additional Notes

None

Related Categories

Image Gallery

Summary

The Good

Good flow cytometry antibody for IL-6 intracellular staining

The Bad

None

The Bottom Line

Intracellular staining antibody for IL-6 cytokine.

Share your experience with other scientists. Write a Review! »

Join the discussion