Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Assay Kits
Assay Kit
Bright-Glo Luciferase Assay System
Supplier Images
Published Figures
Bright-Glo Luciferase Assay System
Bright-Glo Luciferase Assay System
Bright-Glo Luciferase Assay System from Promega
Be the first to write a review!
Citations:
(619)
Figures:
(4)
Supplier Page
Supplier Page from
Promega for
Bright-Glo Luciferase Assay System
Get Pricing
Description
Bright-Glo Luciferase Assay System is designed for continuous-process systems. The robust, homogeneous assay chemistry gives high assay sensitivity and has a 30-minute signal half life
Product Specs
Company Info
Citations
Reviews
Product Reviews
Product Specs
Item
Bright-Glo Luciferase Assay System
Company
Promega
Price
Supplier Page
View Company Product Page
Catalog Number
E2620
Reactivity
Mammalian
Detection Target
Luciferase
Species
Mammalian
Quantity
100ml
Sample Type
Mammalian cells
Method
Luciferase
Sensitivity
Up to tenfold more light intensity than other homogeneous luciferase assay reagents results in increased sensitivity.
Add to Compare List
Promega
2800 Woods Hollow Rd
Madison
,
WI
53711
United States
Phone
: Tel: +1 (608) 274-4330
Fax: +1 (608) 277-2516
Email: custserv@promega.com
techserv@promega.com
Company Profile
Website:
http://www.promega.com
Citations (619)
(1)
Sialic acid cis-ligand dynamics modulate Siglec-7 and -9 function and affect Siglec-7/9 co-blockade to potentiate natural killer cell anti-tumor activity
Oncoimmunology
December 31, 2026
Jesper van Eck van der Sluijs, Anne H. C. Valk, Eline J. H. van Houtum, Esther D. Kers-Rebel, Maaike Looman, Willemijn Hobo, Anna E. Marneth, Harry Dolstra, Lune van den Boogaard, Christian Büll,
et al.
and 5% CO2, followed by
luminescence measurement
using
Bright-Glo™ Luciferase Assay System
(
Promega
,
E2620
) according to the manufacturer’s protocol on a Victor3 Multilabel Plate Reader (Perkin Elmer).
Western blot
(2)
Induced-fit anti-GFRAL antibody ameliorates cancer cachexia and attenuates sympathetic outflow in tumor-bearing mice
Sci Adv
October 30, 2026
Sohyun Kim, Min Hee Lee, Jinsook Ahn, Sang-Hyeon Ju, Dong Sun Lee, Seohyun Choi, Kwang Wook Min, Minho Shong, Ho Min Kim
measured by determining absorbance at 560 nm using the
Bright-Glo Luciferase Assay System
(
Promega
, #
E2620
) and a SpectraMax iD5 microplate reader. Data for
IC50
determination were normalized to the
GDF15
-only
(3)
Regulatable in vivo gene expression via adaptamers
Mol Cell
October 20, 2026
Jack Bryant, Laura Herron, Yesh Doctor, Finn McRae, Jocelyn Wang, Theodore Hirsch, Andrew Portell, Satheesh Kumar, Prashant Mali
System,
Promega
,
N1120
Dextrose,
MilliporeSigma
,
G7021
-1KG "Neutral Buffered Formalin, 10%",MilliporeSigma,HT501128-4L
Bright-Glo™ Luciferase Assay System
,
Promega
,
E2610
RiboGreen®,
ThermoFisher
,
R11491
Purified ADAR1 p150 protein,
BPS Bioscience
,
100472-1
HiScribe® T7 High Yield RNA Synthesis Kit
(4)
Functional redundancy, complementation, and cross-talk between CH25h and IFITM3 in infection and in IFITM3 trafficking and secretion
Journal of Virology
October 20, 2026
Yuxin Song, Tingting Xia, Charlène Martin, Gaetan Despres, Julien Burlaud-Gaillard, Antonin Lamaziere, Philippe Roingeard, Andrea Cimarelli
was quantified after luciferase analysis on cell lysates using the BrightGlow Lysis Reagent (
Promega
E2620
) and the Tecan Spark Luminometer. Infectious
virus
yields under various conditions were consistently
(5)
Direct detection and quantification of HIV particles and their envelope trimers bound by combinations of broadly neutralizing antibodies
iScience
October 16, 2026
Souradip Dasgupta, Aswin T. Srivatsav, Sameer Kumar, George K. Lewis, Anthony L. DeVico, Krishanu Ray
commercial
assays
,Critical commercial
assays
,,
Bright-Glo™ Luciferase Assay System
,
Promega
,Catalog #
E2610
NuPAGE™ 4–12% Bis-Tris Protein Gels,
Thermo Fisher Scientific
,Catalog #
NP0322PK2
Whatman® Optitran®
(6)
Cucurbitacin B suppresses GBM progression by inducing GADD45α-Dependent PCNA downregulation and DNA replication arrest
Front Pharmacol
October 14, 2026
Yonghua Xue, Bin Wang
non-transduced cells. Luciferase activity was quantified using the
Bright-Glo Luciferase Assay System
(
Promega
,
E2620
) and measured on a
Varioskan LUX multimode microplate reader
(
Thermo Fisher Scientific
). Cell populations
(7)
Cancers modulate processing and presentation of p53 neoantigens to evade T cell detection
Immunity
October 13, 2026
Koji Haratani, Bruce Reinhold, Jonathan S. Duke-Cohan, Caroline G. Fahey, Kemin Tan, Robert J. Mallis, Alexander Gusev, Kenneth L. Kehl, Jia Luo, Allyson Karmazyn,
et al.
according to the manufacturer’s instructions. In case of T2 cells, the
Bright-Glo Luciferase Assay System
(
E2610
,
Promega
) was used.
Luminescence
data were obtained two times serially from the same plates to minimize
(8)
Hippo signaling regulates spontaneous human trophoblast syncytialization in three-dimensional cultures
Molecular Human Reproduction
October 7, 2026
Michael Zheng, Lin Zhao, Richard Xi, Jahdiel DeNobrega, Mary Tammo, Stephen J Renaud, Peeyush K Lala
of DMSO in complete TS media for 24 h. Cells were lysed with the
Bright-Glo Luciferase assay system
(
E2610
,
Promega
, Madison, WI, USA), with luciferase activity measured using a VICTOR3V
luminescence
microplate
(9)
Development and Characterization of Pseudotype-based Microneutralization Assay to Assess Functionality of Anti-rabies Protein G Antibodies
F1000Res
October 6, 2026
Antonelli R#, Vezzani G#, Guerrini N, Giovagnoli V, Dapporto F, Iturriza M, Loomis R, Montomoli E, Rossi O, Molesti E,
et al.
72-hour
incubation
at 37°C with 5% CO 2, 50 μL of Bright-Glo™
Luciferase Assay Reagent
(
Promega
, Cat. No.
E2620
) was added per well. The plates were shaken for 5 minutes at 400 RPM using a microplate shaker (Fisherbrand,
(10)
Novel African Rhinolophus bat ACE2 sequences reveal the determinants of Afro-Eurasian sarbecovirus entry
Journal of Virology
September 22, 2026
Yueying Zhang, Shigeru Fujita, Masahiro Kajihara, Katendi Changula, Bernard Mudenda Hang'ombe, Shusuke Kawakubo, Spyros Lytras, Jumpei Ito, Akinori Kanai, Yutaka Suzuki,
et al.
respectively, and infected cells were lysed with a
Bright-Glo Luciferase Assay System
(
Promega
, Cat #
E2620
) 2 days post-
infection
. The luminescent signal was measured using a GloMax Explorer Multimode Microplate
(11)
Intragenic transcription from defective HIV proviruses triggers interferon responses in myeloid cells
Journal of Virology
September 22, 2026
Jonathan M. Kilroy, Aparna A. Deokar, Samantha Patalano, Juan I. Fuxman Bass, Manish Sagar, Suryaram Gummuluru, Andrew J. Henderson
media/supernatant was aspirated from these plates, and 30 µL of BrightGlo reagent (
Promega
Catalog No.
E2610
) was added to lyse the cells and
measure
luciferase activity. A standard curve was generated by adding
(12)
Intravenously deliverable oncolytic virus VET3-TGI favorably alters the tumor microenvironment
Journal for immunotherapy of cancer
September 21, 2026
Zhang M, Barrett K, Carter C, Sampath P, Acosta-Barreto G, Audino S, Moongdee J, Bouchard R, Dunstane D, Matteo N,
et al
.
final concentrations shown. Signal was developed using a Bright-Glo luciferase
assay
kit (
Promega
,
E2620
) and measured using a Spark 10M plate reader. Detection of
CXCR3
expression on infected
peripheral blood mononuclear cells
(13)
A NanoLuc-Based Protease Biosensor for Highly Sensitive Detection of Intracellular Protease Activity: Applications to Apoptosis and Coronavirus Infection
Bio Protoc
September 20, 2026
Masashi Arakawa, Eiji Morita
(
Promega
, catalog number:
N1120
) 2. Bright-GloTM luciferase
assay
system (
Promega
, catalog number:
E2620
)
Lysis buffer
components 1. NaCl (Nacalai Tesque, catalog number: 31320-05) 2. Tris (Tris[hydroxymethyl]aminomethane)
(14)
Identification of Galectin-9 (Gal-9) as a B7-H4 binding partner and characterization of their glycosylation-dependent interaction that modulates T cell signaling within a multi-ligand/receptor network
PLoS One
September 18, 2026
Ravear Zhiqiang Wang, Fang Yang, Jianhua Sui
was quantified by measuring
luminescence
using the
Bright-Glo™ Luciferase Assay System
Kit (
Promega
,
E2620
). MC38-mB7-H4 stable cells were established by transducing MC38 cells with
lentiviruses
expressing the
(15)
Convergent use of aminopeptidase N receptor by hedgehog merbecoviruses
Nature Microbiology
September 16, 2026
Peng Liu, Qianhui Zhu, Jingyi Liu, Zhixing Ma, Guocui Mou, Yuanling Yu, Chen Liu, Chengbao Ma, Junyu Si, Xiao Yang,
et al.
luciferase activity was measured using the
Bright-Glo Luciferase Assay System
(
Promega
, catalogue no.
E2620
) on a Thermo Varioskan LUX or
GloMax 20/20 Luminometer
(
Promega
). For pseudovirus entry
assays
in primary
(16)
Suidae iPSC-derived macrophages as models for investigating susceptibility and resilience to African swine fever virus
Stem Cell Reports
September 8, 2026
Tom M. Watson, Lynnette C. Goatley, Stephen Meek, Lel Eory, Sylvia Kohler, Nicholas Berkley, Sofia Sternberg, Melany Jackson, Amy Findlay, Isabella Hoskins,
et al.
(
Promega
#
E2661
) and transferred to white 96 well plates. An equal volume of Bright-Glo reagent (
Promega
, #
E2610
) was added and incubated for 5 min. The plates were read on a Promega GloMax Discovery microplate reader,
(17)
Microfluidic-based rapid generation of chimeric antigen receptor T cells improves low-multiplicity-of-infection transduction efficiency while preserving functional activity
J Transl Med
September 5, 2026
Ying Jiang, Guidong Zhu, Haiyan Zhang, Dongqi Tang
Residual viable target-cell signal was quantified using the
Bright-Glo Luciferase Assay System
(
Promega
;
E2610
) on a microplate luminometer (Molecular Devices, San Jose, CA). Specific lysis was calculated as 1 -
(18)
Emergence of neutralizing RBD antibodies following Omicron infection with limited activity against ancestral SARS-CoV-2
iScience
August 21, 2026
Michael S. Piepenbrink, Yao Ma, Simran Panjwani, Alexandra R. Blake, Allison M. Bell, James L. Kizziah, Sara H. Mahmoud, Gregory C. Ippolito, Nathan B. Erdmann, Paul A. Goepfert,
et al.
(Fc) capture kit,Cytival Life Sciences,Cat#BR100839
Bright-Glo™ Luciferase Assay System
,
Promega
,Cat#:
E2620
,, Deposited data,Deposited data,Deposited data ,, 1332D4-S(KP3.1.1) Structure,This study,PDBID
(19)
SARS-CoV-2 Neutralization Breadth Is Shaped by Variant Exposure and Immune History
J Med Virol
August 13, 2026
Greta Vizgirda, Alexander P. Underwood, Ulrik Fahnøe, Christina Sølund, Signe Lysemose Villadsen, Andrea Galli, Nina Weis, Jens Bukh
quantified by measuring
luminescence
using the
Bright‐Glo Luciferase Assay System
(
Promega
; Cat. No.
E2610
) and the
FLUOstar Omega
microplate reader (
BMG Labtech
).
Infection
was considered positive when
luminescence
(20)
Directed evolution of a stem-helix-targeting antibody enables MERS-CoV cross-neutralization through enhanced binding affinity
PLoS Pathog
August 7, 2026
Panpan Zhou, Meng Yuan, Yuexiu Zhang, Oliver Limbo, Ge Song, Fangzhu Zhao, Hejun Liu, Wan-Ting He, Tazio Capozzola, Sean Callaghan,
et al.
well. After 48h of
incubation
, luciferase activity was measured by BrightGlo substrate (
Promega
Cat#
E2620
) according to the manufacturer’s instructions. Fifty percent maximal inhibitory concentrations (IC50s)
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
Product Reviews
Bright-Glo™ Luciferase Assay From Promega
When it comes to performing cellular proliferation assays, choosing an assay type and readout method...
Read More
Bright-Glo™ Luciferase Assay System From Promega
Cell-based assays that use luciferase as a reporter are common in molecular biology. A number of ...
Read More
Bright-Glo Luciferase Assay System from Promega
Supplier Page
View Company Product Page
Product Specs
Company Info
Citations
Reviews
Product Reviews
Back To Top