Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Assay Kits
Assay Kit
Bright-Glo Luciferase Assay System
Supplier Images
Bright-Glo Luciferase Assay System
Bright-Glo Luciferase Assay System
Bright-Glo Luciferase Assay System from Promega
Be the first to write a review!
Citations:
(93)
Supplier Page
Supplier Page from
Promega for
Bright-Glo Luciferase Assay System
Get Pricing
Ask a Question
Description
Bright-Glo Luciferase Assay System is designed for continuous-process systems. The robust, homogeneous assay chemistry gives high assay sensitivity and has a 30-minute signal half life
Product Specs
Company Info
Citations
Reviews
Product Reviews
Product Specs
Item
Bright-Glo Luciferase Assay System
Company
Promega
Price
Supplier Page
View Company Product Page
Catalog Number
E2650
Reactivity
mammalian
Species
mammalian
Detection Target
Luciferase
Sensitivity
Up to tenfold more light intensity than other homogeneous luciferase assay reagents results in increased sensitivity.
Sample Type
Mammalian cells
Method
Luciferase
Quantity
10 x 100ml
Add to Compare List
Promega
2800 Woods Hollow Rd
Madison
,
WI
53711
United States
Phone
: Tel: +1 (608) 274-4330
Fax: +1 (608) 277-2516
Email: custserv@promega.com
techserv@promega.com
Company Profile
Website:
http://www.promega.com
Citations (93)
(1)
Neutralizing antibody responses to the primary series of a COVID-19 mRNA vaccine in the cancer cohort under active treatment
Human Vaccines & Immunotherapeutics
December 31, 2025
Huijing Xue, Troy J. Kemp, Chenglei Li, Nancy V. Roche, Ziad Bakouny, Chris Labaki, Guo-Shou Mary Lee, Rachel Trowbridge, Sarah Strauss, Melissa E. Hughes,
et al.
After a 10-min
incubation
at room temperature, 100 μL of Bright-Glo luciferase reagent (
Promega
, Cat#
E2650
) was added to each well, mixed, and 110 μL of the mixture from each well was added to a white 96-well
(2)
Marked neurotropism and potential adaptation of H5N1 clade 2.3.4.4.b virus in naturally infected domestic cats
Emerging Microbes & Infections
December 31, 2025
Shubhada K. Chothe, Surabhi Srinivas, Sougat Misra, Noel Chandan Nallipogu, Elizabeth Gilbride, Lindsey LaBella, Swastidipa Mukherjee, Christian H. Gauthier, Heidi L. Pecoraro, Brett T. Webb,
et al.
HEK-293
T cells
and measuring the luciferase expression using BrightGlo reagent (
Promega
, USA, catalog #
E2650
). The relative
luminescence
units (RLU) were measured using
BioTek
Cytation 7
Cell Imaging Multimode
(3)
In vitro comparison of the susceptibilities of the same drug resistance mutations to reverse-transcriptase inhibitors of subtype B and CRF01_AE HIV-1 strains
Sci Rep
October 15, 2025
Hanping Li, Kuiling Shen, Jingwan Han, Yongjian Liu, Lixuan Zhang, Xiling Liu, Lei Jia, Bohan Zhang, Xiaolin Wang, Jingyun Li,
et al.
determined on an EnSpire plate reader by adding a Bright-Glo
fluorescence
mixture (
Promega
, Cat. No.
E2650
). With 2.5 times the RLU of the blank control wells used as the cut-off, a well was considered positive
(4)
Signatures of omicron-like adaptation in early SARS-CoV-2 variants and chronic infection
Cell Reports
August 26, 2025
Mark Tsz Kin Cheng, Mazharul Altaf, Jesu Castin, Ann-Kathrin Reuschl, Benjamin L. Sievers, Kimia Kamelian, Dejan Mesner, Rebecca B. Morse, Adam Abdullahi, Bo Meng,
et al.
,
Cell Signaling Technology
,Cat#
9803
Critical commercial
assays
,Critical commercial
assays
,Critical commercial
assays
Bright-Glo,
Promega
,Cat#
E2650
QuikChange Lightning,
Agilent
,Cat#
210518
QuantiTect SYBR Green
PCR Kit
,
Qiagen
,Cat#
204143
Clarity Western
(5)
A DNA vaccine candidate provides protection against Rift Valley Fever virus in sheep under natural field conditions
Frontiers in Cellular and Infection Microbiology
August 26, 2025
Moufid Mhamadi, George (Giorgi) Babuadze, Aminata Badji, Marie-Edith Nepveu-Traversy, El Hadji Ndiaye, Alioune Gaye, Mignane Ndiaye, Moundhir Mhamadi, Frank William Mendy, Cheikh Talibouya Touré,
et al.
Monroe, NC #655083). After 72 hours,
luminescence
was measured using Bright-Glo (
Promega
, Madison, WI, #
E2650
) and a microplate reader (Biotek Synergy). The reciprocal of the serum dilution required to reduce the
(6)
Fragment-Based Development of Small Molecule Inhibitors Targeting Mycobacterium tuberculosis Cholesterol Metabolism
J Med Chem
July 24, 2025
Madeline E. Kavanagh, Kirsty J. McLean, Sophie H. Gilbert, Cecilia N. Amadi, Matthew Snee, Richard B. Tunnicliffe, Kriti Arora, Helena I. M. Boshoff, Alexander Fanourakis, Maria Jose Rebollo-Lopez,
et al.
proportional to
bacterial load
, was determined by using the BrightGlo
Luciferase Assay System
(
Promega
, #
E2650
) according to the manufacturer’s protocol, except that 20 μL of Bight-Glo mix was used instead of 50
(7)
Computationally designed proteins mimic antibody immune evasion in viral evolution
Immunity
June 10, 2025
Noor Youssef, Sarah Gurev, Fadi Ghantous, Kelly P. Brock, Javier A. Jaimes, Nicole N. Thadani, Ann Dauphin, Amy C. Sherman, Leonid Yurkovetskiy, Daria Soto,
et al.
al.34,N/A
Steady-Glo Luciferase Assay System
,
Promega
,Cat#
E2550
Bright-Glo Luciferase Assay System
,
Promega
,Cat#
E2650
HIV
pseudotyping
assay
,Yurkovetskiy et al.34,N/A Deposited data,Deposited data,Deposited data
SARS-CoV-2
(8)
Ethnic Comparisons of Spike-Specific CD4+ T Cells, Serological Responses, and Neutralizing Antibody Titers Against SARS-CoV-2 Variants
Vaccines (Basel)
June 4, 2025
Fani Pantouli, Vanessa Silva-Moraes, Ted M. Ross
Two days later, cells were incubated in equal volume of Bright-GloTM
Luciferase Assay system
(Cat no.
E2650
,
Promega
, Madison, WI, USA) at a
1:1
ratio for 5 min in the dark at room temperature. Cells were then
(9)
Design of a fragment crystallizable-engineered tetravalent bispecific antibody targeting programmed cell death-1 and vascular endothelial growth factor with cooperative biological effects
iScience
March 21, 2025
Tingting Zhong, Lingzhi Zhang, Zhaoliang Huang, Xinghua Pang, Chunshan Jin, Wenrong Liu, Juan Du, Wen Yin, Na Chen, Jing Min,
et al.
and then diluted at 3-fold from 1000 nM to 0.00123 nM. After
incubation
, Bio-Glo™ Reagent (
Promega
,
E2650
) was then added and incubated for 5-30 minutes. The
luminescence
was quantified using Envision multimode
(10)
High-Throughput Repurposing Screen Reveals Compounds with Activity against Toxoplasma gondii Bradyzoites
ACS Infectious Diseases
March 14, 2025
Taher Uddin, Jing Xia, Yong Fu, Case W. McNamara, Arnab K. Chatterjee, L. David Sibley
medium was aspirated to 20 μL using a Biotek ELx405CW, 20 μL of Promega Bright-Glo reagent (
Promega
E2650
) was dispensed into each well, and the plates were covered with a black lid. The plates were then incubated
(11)
Lanatoside C activates the E3 ligase STUB1 to inhibit FOXP3 transcriptional activity and promote antitumor immunity
EMBO Molecular Medicine
February 20, 2025
Qian Zhou, Tong Yang, Xixi Yu, Bo Li, Jin Liu, Yongxin Mao, Rongxiang Guo, Zhuo Feng, Li Zhou, Guandi Zeng,
et al.
Flow cytometry
,"
BD FACSCelesta
,
BD
FACSAria
II,
BD LSRFortessa
", Bright-GloTM
Luciferase Assay System
,
Promega
,
E2650
His-tag Protein Purification Kit,Beyotime,P2226 CD4+CD25+
regulatory T cell
isolation kit,
Miltenyi
,
130-091-041
MojoSort mouse CD4+ T cell isolation kit
(12)
HPPE Activates NRF2 Signaling by Liberating Heavy Metal Stores
Chembiochem : a European journal of chemical biology
February 16, 2025
Freeman R, Bollong MJ.
7x concentrate for a final concentration of 1x. 24 hours later, 30 μL of BrightGlo reagent (
Promega
,
E2650
), diluted
1:3
in water, was added and
luminescence
read on an Envision plate reader.
Western Blotting
. Cells
(13)
Evaluation of population immunity against SARS-CoV-2 variants, EG.5.1, FY.4, BA.2.86, JN.1, JN.1.4, and KP.3.1.1 using samples from two health demographic surveillance systems in Kenya
BMC Infectious Diseases
December 28, 2024
Doreen Lugano, Bernadette Kutima, Makobu Kimani, Antipa Sigilai, John Gitonga, Angela Karani, Donald Akech, Boniface Karia, Abdhalah K. Ziraba, Angela Maina,
et al.
read on a Luminometer with luciferase substrate according to the manufacturer’s instructions (
Promega
,
E2650
). The percentage of neutralization was calculated using the following equation: 100 × (1− (RLU of sample
(14)
Kinetics of naturally induced binding and neutralising anti-SARS-CoV-2 antibody levels and potencies among SARS-CoV-2 infected Kenyans with diverse grades of COVID-19 severity: an observational study
Wellcome Open Research
December 2, 2024
John Kimotho, Yiakon Sein, Shahin Sayed, Reena Shah, Kennedy Mwai, Mansoor Saleh, Perpetual Wanjiku, Jedidah Mwacharo, James Nyagwange, Henry Karanja,
et al.
Glo lysis buffer 1X
(
Promega
,
E2661
), luciferase activity was measured by adding Bright-Glo (
Promega
,
E2650
) and
luminescence
was measured using BioTek
Synergy H1
multimode reader. Neutralisation was measured
(15)
Greater preservation of SARS‐CoV‐2 neutralising antibody responses following the ChAdOx1‐S (AZD1222) vaccine compared with mRNA vaccines in haematopoietic cell transplant recipients
British Journal of Haematology
December 1, 2024
Hayley Colton, Natalie Barratt, Nigel Temperton, Hailey Hornsby, Adrienn Angyal, Irina Grouneva, Benjamin B. Lindsey, Pamela Kearns, Eleanor Barnes, Carl S. Goodyear,
et al.
further 48 h
incubation
. Supernatant was removed and 30 μL of
Bright‐Glo™Luciferase Assay System
(
Promega
E2650
) diluted
1:1
with phosphate buffered saline was added to each well.
Luminescence
in RLU was read on
(16)
ART-DEX: A novel strategy to monitor broadly neutralizing antibody activity during antiretroviral therapy of HIV-1
STAR Protocols
September 20, 2024
Magdalena Schwarzmüller, Alexandra Trkola
desalting
plates, 40K MWCO",Thermo Fisher Scientific,A57767
Bright-Glo Luciferase assay system
,
Promega
,
E2650
,,
Experimental models
: Cell lines,
Experimental models
: Cell lines,
Experimental models
: Cell lines ,, TZM-bl
(17)
Stapokibart (CM310) targets IL-4Rα for the treatment of type 2 inflammation
iScience
September 20, 2024
Liu W, Zhao Y, He Y, Yan X, Yu J, Song Q, Zhang L, Dong B, Xu G, Wang C,
et al
.
assays
,, Amine Coupling Kit,GE Healthcare,BR-1000-50
Bright-Glo Luciferase assay system
,
Promega
,
E2650
Cell Titer-Glo Luminescent
Cell Viability Assay
,
Promega
,
G7572
Human TARC Quantikine ELISA kit,
R&D systems
(18)
Decoupling HIV-1 antiretroviral drug inhibition from plasma antibody activity to evaluate broadly neutralizing antibody therapeutics and vaccines
Cell Reports Medicine
September 17, 2024
Magdalena Schwarzmüller, Cristina Lozano, Merle Schanz, Irene A. Abela, Silvan Grosse-Holz, Selina Epp, Martina Curcio, Jule Greshake, Peter Rusert, Michael Huber,
et al.
Desalting
Plates, 40K MWCO",ThermoFisher Scientific,A57767
Bright-Glo Luciferase Assay System
,
Promega
,
E2650
CellTiter-Glo Luminescent Cell Viability Assay
,
Promega
,
G7570
QuikChange II Site-directed mutagenesis
(19)
Genetic ablation of adhesion ligands mitigates rejection of allogeneic cellular immunotherapies
Cell Stem Cell
September 5, 2024
Quirin Hammer, Karlo Perica, Rina M. Mbofung, Hanna van Ooijen, Karen E. Martin, Pouria Momayyezi, Erika Varady, Yijia Pan, Mark Jelcic, Brian Groff,
et al.
Concentrator,Takara,631232 Retro-X Concentrator,Takara,631456
RetroNectin
,
Takara
,
T100B
Bright-Glo Luciferase Assay System
,
Promega
,
E2650
Experimental models
: Cell lines,
Experimental models
: Cell lines,
Experimental models
: Cell lines K562,ATCC,CVCL_0004 K562–HLA-C2SC,This
(20)
SARS-CoV-2 Mpro inhibitor identification using a cellular gain-of-signal assay for high-throughput screening
SLAS Discovery
September 1, 2024
Renee Delgado, Jyoti Vishwakarma, Seyed Arad Moghadasi, Yuka Otsuka, Justin Shumate, Ashley Cuell, Megan Tansiongco, Christina B. Cooley, Yanjun Chen, Agnieszka Dabrowska,
et al.
Gain-of-signal readouts were initiated by adding 5 μl/well of Bright-Glo reagent (
Promega
catalog no.
E2650
), and after an additional 10 min room temperature
incubation
,
firefly
luciferase activity was measured
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
Product Reviews
Bright-Glo™ Luciferase Assay From Promega
When it comes to performing cellular proliferation assays, choosing an assay type and readout method...
Read More
Bright-Glo™ Luciferase Assay System From Promega
Cell-based assays that use luciferase as a reporter are common in molecular biology. A number of ...
Read More
Bright-Glo Luciferase Assay System from Promega
Supplier Page
View Company Product Page
Product Specs
Company Info
Citations
Reviews
Product Reviews
Back To Top