Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
White Paper
Register
Sign In
Biocompare
Products
Assay Kits
Assay Kit
ONE-Glo Luciferase Assay System
Supplier Images
ONE-Glo Luciferase Assay System
ONE-Glo Luciferase Assay System
ONE-Glo Luciferase Assay System from Promega
Be the first to write a review!
Citations:
(133)
Supplier Page
Supplier Page from
Promega for
ONE-Glo Luciferase Assay System
Get Pricing
Description
The ONE-Glo Luciferase Assay System provides a sensitive, robust, homogeneous assay for detection of firefly luciferase reporter gene expression in mammalian cells. Ideal for high- and ultrahigh-throughput applications
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
ONE-Glo Luciferase Assay System
Company
Promega
Price
Supplier Page
View Company Product Page
Catalog Number
E6120
Sample Type
Mammalian cells
Method
ONE-Glo Assay System
Quantity
100ml
Detection Target
Luciferase
Add to Compare List
Promega
2800 Woods Hollow Rd
Madison
,
WI
53711
United States
Phone
: Tel: +1 (608) 274-4330
Fax: +1 (608) 277-2516
Email: custserv@promega.com
techserv@promega.com
Company Profile
Website:
http://www.promega.com
Citations (133)
(1)
Genetic code expansion for single noncanonical amino acid incorporation into SARS-CoV-2 Omicron spike on amber-free lentiviral particles
Methods in Enzymology
June 25, 2026
Wang Xu, Narendra Kumar Gonepudi, Yang Han, Maolin Lu
A1296
Q5® site-directed mutagenesis kit
,
NEB
,Cat #
E0554S
ONE-Glo™ luciferase assay system
,
Promega
,Cat #
E6120
4x
Laemmli sample buffer
,
Bio-Rad
,Cat # 1610747
Experimental Models
: Cell Lines,
Experimental Models
:
(2)
Bioorthogonal click-chemistry labeling and visualization of dual noncanonical amino acid-incorporated HIV-1 Env on intact virions
Methods in Enzymology
June 25, 2026
Narendra Kumar Gonepudi, Wang Xu, Harry Baffour Awuah, Maolin Lu
A1296–1KG
Q5® Site-Directed Mutagenesis Kit
,
NEB
,Cat #
E0554S
ONE-Glo™ Luciferase Assay System
,
Promega
,Cat #
E6120
6x Laemmli sample buffer,
Thermo scientific
,Cat #
J61337.AD
Experimental Models
: Cell Lines,
Experimental Models
(3)
From iPSC to manufactured iNK cells using CombiCult® screening platform
Front Cell Dev Biol
June 11, 2026
Marina Tarunina, Sachin Luharia, Matthew Houppermans, Giuseppe D'Agostino, Lam Lam, Michelle Gestwa, Aleksandra Habich-Crayton, Marcia Mata, Juline Guenat, Molly Tregidgo,
et al.
to plot cytotoxicity graphs. For luciferase-based
assay
,
ONE-Glo Luciferase Assay System
(
Promega
,
E6120
) was used according to manufacturer’s protocol.
Luminescence
was measured using
CLARIOstar
(
BMG LABTECH
).
(4)
ω-3PUFAs Inhibit Gallbladder Cancer Through Enhancing STK31 Methylation
Mol Nutr Food Res
June 11, 2026
Shuang-Xing Li, Wei-Yu Zhu, Hai-Ying Peng, Bin Zhang, Zhu-Ying Lin, Song-Lin Yang, Yi-Yi Zhao, Hui Gao, Shan He, Yuan Liu,
et al.
cells were established after puromycin selection and validated using
ONE‐Glo Luciferase Assay System
(
E6120
,
Promega
, Madison, USA). The nude
mice
were also pre‐treated with ω‐3PUFAs (350 mg/kg/day) or
corn
oil
(5)
Live-cell Pick-Seq (LiP-Seq): Interrogating ultra-rare mantle cell lymphoma persistent cells after CART19 therapy
Blood Advances
June 9, 2026
Ran Xu, Gongwei Wu, Siobhan Rice, Matthew Booker, Jenalyn Celine Weekes, Hayden Luke Bell, Yifei Gao, Ajit J. Nirmal, Huiyun Liu, Zoe Ciantra,
et al.
coincubation, the cell lysate was prepared using the
ONE-Glo luciferase assay system
(
Promega
, catalog no.
E6120
). The luciferase activity was measured with a
Synergy Neo2
luminescence
microplate reader (
Biotek
). All
(6)
Monocytes Derived From Human Pluripotent Stem Cells Engineered for Detection of Pyrogens
Cell Proliferation
May 21, 2026
Jingjing Liu, Bingyu Cai, Tingting Gao, Wumei Wei, Liu Wang, Qi Zhou, Wei Li, Jie Hao, Jun Wu
Luciferase Reporter Assay
The
luciferase reporter assay
was conducted using the
Luciferase Reporter Assay
System (
E6120
,
Promega
) according to the manufacturer's instructions. Briefly,
hESCs
or
monocyte
differentiation from
(7)
Predictive modeling of immune escape and antigenic grouping of SARS-CoV-2 variants
Journal of Virology
May 19, 2026
Arshan Nasir, Diana Lee, Laura E. Avena, Daniela Montes Berrueta, Tessa Speidel, Kai Wu, Yadunanda Budigi, Andrea Carfi, Guillaume B. E. Stewart-Jones, Darin Edwards
cells for 18 hours at 37°C. At 18 hours after
infection
, an equal volume of One-Glo reagent (
Promega
,
E6120
) was added to the culture medium for readout using a BMG PHERastar-FSX plate reader. The percentage
(8)
MHY5456, an FXR Agonist, Ameliorates Hepatic Steatosis and Fibrosis in a Mouse Model of MASLD
Biomolecules & Therapeutics
May 1, 2026
Mi-Jeong Kim, Hyejin Kang, Jian Yoo, Sugyeong Ha, Jeongwon Kim, Byeong Moo Kim, Da Eun Park, Hae Young Chung, Donghwan Kim, Hyung Ryong Moon,
et al.
FXR was measured using the
One-Glo Luciferase Assay System
(
Promega
, Madison, WI, USA; catalog number
E6120
).
Luminescence
was measured as an indicator of FXR transcriptional activity with a
luminescence
plate
(9)
Developing a multimodal therapy for glioblastoma using oncolytic virus delivering CD19 and EGFRvIII antigens and bi-specific CARs
Nature Communications
April 9, 2026
Jia Li, Shyambabu Chaurasiya, Guihua Sun, Qi Cui, Peng Ye, Yue Qin, Tao Zhou, Xiuli Wang, Yuman Fong, Marcela V. Maus,
et al.
and subjected to a
luciferase reporter assay
with the
ONE-Glo™ Luciferase Assay System
(
Promega
, Cat#
E6120
).
Flow cytometry analysis
ESCs and GBM cells were dissociated with Accutase (Gibco, Cat#
A1110501
)
(10)
Quantitative high-throughput screening identifies small-molecule modulators of Wnt/β-catenin signaling
Front Pharmacol
April 2, 2026
Xing Chen, Shu Yang, Srilatha Sakamuru, Chainarong Sukhawanit, Savannah Wood, Masato Ooka, Ruili Huang, Menghang Xia
and 5% CO2. Luciferase activity was measured using ONE-Glo
Luciferase Assay reagent
(
Promega
, Cat #
E6120
) according to the manufacturer’s instructions. Four µL of reagent was added directly to each well, and
(11)
Design-driven optimization of low-cost reagent formulations for reproducible and high-yielding cell-free gene expression
Nature communications
March 5, 2026
Olsen ML, Copeland CE, Sundberg CA, Aw R, Shaver ZM, Rao G, Swartz JR, Karim AS, Jewett MC.
with expressed luciferase were diluted tenfold and mixed with
ONE-Glo Luciferase Assay System
(
Promega
E6120
) in a 15:1 ONE-Glo to diluted reaction ratio.
Luminescence
was measured on a BioTek Neo2 plate reader
(12)
Pharmacological perturbation of splicing elicits SMG1 reduction: Implications for cancer therapy
iScience
February 20, 2026
Martin Barainka, Angelina Zheleva, Angela Pérez-Cervera, Helena Villanueva, Daniel Meraviglia-Crivelli, Beatriz Moreno, Fernando Pastor
SYBR™ Green Master Mix,
Applied Biosystems
,Cat#
4385612
ONE-Glo™ Luciferase Assay System
,
Promega
,Cat#
E6120
Zombie Green™ Fixable Viability Kit
,
BioLegend
,Cat#
423111
,, Deposited data,Deposited data,Deposited
(13)
Development and characterization of immortalized mouse intestinal epithelial cell lines
Scientific Reports
February 11, 2026
Julie Y. Zhou, Scott T. Espenschied, Qiuhe Lu, Paul E. Karell, Kelsey J. Lewis, Kevin P. Newhall, Yi Han, Meera Bambroo, Amalu Job, Thaddeus S. Stappenbeck
without LPS (500 ng mL−1) for 4 h. At the experimental endpoint, 50 µL of ONE-Glo Reagent (
Promega
, Cat#
E6120
) was added to each well, and
luminescence
was measured using a BioTek
Cytation5
plate reader. Signal
(14)
Affinity maturation and light-chain-mediated paratope diversification anticipates viral evolution
Cell Reports
January 27, 2026
John Dingus, Duck-Kyun Yoo, Sachin Kumar, Yajuan Wang, Md Golam Kibria, Shahab Saghaei, Zahra Allahyari, Jessica W. Chen, Natalie M. Caputo, Jason Hwang,
et al.
L3000008
ExpiFectamine Kit,
Thermo Fisher Scientific
,Cat#
A14525
ONE-Glo luciferase assay system
,
Promega
,Cat#
E6120
EZ-Link™ Sulfo-NHS-LC-Biotin
,
Thermo Fisher Scientific
,CAT#
21338
Cell lines,Cell lines,Cell lines HEK293T,
ATCC
,Cat#
(15)
SLC25A11-mediated reprogramming of mitochondrial redox state and lipid peroxidation confers NRF2-dependent ferroptosis resistance in biliary tract cancer
Cellular & Molecular Biology Letters
January 9, 2026
Yu-Yu Lin, Han-Hsi Kuo, Zhao-Jing He, Hsin-Yi Chung, Cheorl-Ho Kim, Yi-Ru Pan, Meng-Ju Wu, Ming-Hsien Chan, Chun-Nan Yeh, Nai-Jung Chiang,
et al.
signals were measured by using a plate reader (Victor3, PerkinElmer) and ONE-Glo Luciferase
assay
(#
E6120
,
Promega
). Relative luciferase activity was calculated by normalizing luciferase activity to cell viability.
(16)
Targeting β-catenin degradation with GSK3β inhibitors induces cell death in acute lymphoblastic leukemia
Nature Cancer
January 8, 2026
Kadriye Nehir Cosgun, Huda Jumaa, Mark E. Robinson, Zhangliang Cheng, Salim Oulghazi, Kohei Kume, David Fonseca Arce, Nikol Agadzhanian, Klaus M. Kistner, Etienne Leveille,
et al.
fetal calf serum. Luciferase activity was measured by adding 100 µl of ONE-Glo buffer from
Promega
(
E6120
) using a GloMax plate reader (Promega).
Cell viability assay
In total, 10,000–40,000 cells were seeded
(17)
P329G-engager: a universal mix & match antibody-based adaptor platform for cancer immunotherapy
MAbs
December 16, 2025
Marlena Surowka, Diana Darowski, Idil Hutter-Karakoc, Christina Claus, Claudia Ferrara-Koller, Anne Freimoser-Grundschober, Thomas Hofer, Johannes Sam, Reto Gianotti, Andrzej Sobieniecki,
et al.
After the
incubation
time, 40 µl of a luciferase substrate, ONE-Glo
Luciferase Assay reagent
(
Promega
#
E6120
) was used, allowing for a measurement of relative
luminescence
units (RLU). Readout was performed using
(18)
SARS-CoV-2 Serological Surveillance of Both Vaccinated and Unvaccinated Zoo Animals with the Identification of a Sloth Bear and a Tapir with Previous Infection
Viruses
October 31, 2025
Marie Arvidson, Yashaswi Raj Subedi, Sandipty Kayastha, Angel Mitchell, Kami Alvarado, Xufang Deng, Karen Terio, Matthew Allender, Leyi Wang
the cells were measured for luciferase activity using the ONE-Glo reagent (
Promega
, Madison, WI, USA,
E6120
). Briefly, 50 µL of media was removed from all wells, leaving around 50 µL in each well. 50 µL One-Glo
(19)
Benzoxazole Derivatives as Potent FXR and PPARα Dual Agonists With Anti-Fibrotic and Metabolic Regulatory Effects
MedComm (2020)
October 26, 2025
Mi-Jeong Kim, Dong-Gyun Han, Hyeon Seo Park, Sugyeong Ha, Sang Gyun Noh, Jeongwon Kim, Ji-An Yoo, Byeong Moo Kim, Khas-Erdene Battogtokh, Soohwan Oh,
et al.
PPARα were measured using the
One‐Glo Luciferase Assay System
(
Promega
, Madison, WI; catalog number
E6120
).
Luminescence
was recorded using a
luminescence
plate reader (Berthold Technologies GmbH & Co., Bad
(20)
Selective agonists of KIR and NKG2A to evade missing self response of natural killer cells
Scientific Reports
September 29, 2025
Satoshi Hiura, Yuto Kuwasaki, Yosuke Nishikawa, Takako Kimura, Sayaka Yoshida, Makiko Nakayama, Tomohiro Makino, Suguru Ueno
for 2.5–8 h, luciferase activity of each well was detected using a
Luciferase Assay System
(
Promega
,
E6120
), in accordance with the manufacturer’s instructions. The percentage of specific lysis was calculated
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
ONE-Glo Luciferase Assay System from Promega
Supplier Page
View Company Product Page
Product Specs
Company Info
Citations
Reviews
Back To Top