Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Assay Kits
A Guide to Choosing the Right ELISA Kit
ELISA Kit
Cyclic AMP ELISA Kit
Supplier Images
Published Figures
Cyclic AMP ELISA Kit
Cyclic AMP ELISA Kit
Cyclic AMP ELISA Kit from Cayman Chemical
Be the first to write a review!
Citations:
(110)
Figures:
(2)
Supplier Page
Supplier Page from
Cayman Chemical for
Cyclic AMP ELISA Kit
Request Info
Description
cAMP is a ubiquitous cellular second messenger that is a critical component of a signal transduction pathway linking membrane receptors and their ligands to the activation of internal cellular enzymatic activity and gene expression
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
Cyclic AMP ELISA Kit
Company
Cayman Chemical
Price
$1,586.00
Supplier Page
View Company Product Page
Catalog Number
581001
Quantity
480 Solid
Applications
ELISA
Detection Range
0.078-10 pmol/ml
Sensitivity
80% B/B0: 0.1 pmol/ml
Research Area
cAMP Signaling, Cell Biology, Cell Signaling
Source/Expression System
Animal/Bovine:Animal/Eel:Animal/Mouse:Animal/Rabbit
Origin
USA
Storage
-20
Add to Compare List
Cayman Chemical
Cayman Chemical Company 1180 East Ellsworth Road
Ann Arbor
,
Michigan
48108
United States
Phone
: (800) 364-9897
(734) 971-3640
Company Profile
Website:
http://www.caymanchem.com/
Citations (110)
(1)
Specific GPCRs Elicit Unique Extracellular Vesicle MiRNA Array Signatures: An Exploratory Study
eLife
March 20, 2026
Xiao Shi, Michelle C Palumbo, Sheila Benware, Jack Wiedrick, Sheila Markwardt, Aaron J Janowsky
min before CCPA addition. cAMP accumulation was measured using a cAMP EIA kit from
Cayman Chemical
(
581001
, Ann Arbor, MI, USA), according to the manufacturer’s instructions. All the experiments were conducted
(2)
ADT-030, a novel PDE10 inhibitor, demonstrates potent antitumor activity in pancreatic ductal adenocarcinoma
bioRxiv
February 17, 2026
Dhana Sekhar Reddy Reddy Bandi, Ganji Purnachandra Nagaraju, Sujith Sarvesh, Jeremy B. Foote, Adam B. Keeton, Xi Chen, Veronica Ramirez-Alcantara, Thomas Holmes, Mehmet Akce, Anju Singh,
et al.
intracellular cAMP and cGMP levels were measured.
Enzyme immunoassay
kits were used to detect cAMP (Cat#
581001
,
Cayman
) and cGMP (Cat#
581021
,
Cayman
) by following manufacturer’s instructions. The results were expressed
(3)
Mast cell-specific CysLT2 receptor signaling inhibits cysteinyl leukotriene-dependent mast cell activation and type 2 allergic lung inflammation
Cell Reports
January 27, 2026
Jun Nagai, Madeline M. Hastings, Airi Nishida, Sreyashi Majumdar, Kendall Zaleski, Sofia A. Marshall, Junrui Lin, Mira A.S. Saliman, Yumi Tani, Yamato Murakami,
et al.
ELISA,R&D,DY413 IL-33 mouse ELISA,R&,M3300 "
Cyclic AMP ELISA Kit
, 96 strip wells",
Cayman Chemical
,
581001
Cysteinyl Leukotriene ELISA Kit
,
Cayman Chemical
,
500390
Prostaglandin D2-MOX ELISA Kit
,
Cayman Chemical
,Item
(4)
Adenosine/A 2A R/PKA signaling regulates HO-1-mediated anti-inflammatory responses during Leishmania donovani infection
mBio
January 14, 2026
Tapasi Das, Pronay Brahmachari, Anindita Ukil
Mouse TNF alpha ELISA Kit
,
Abcam
,
ab100747
,
ab100747
,
Mouse IL-12 p40 + IL-12 p70 ELISA Kit
,
Abcam
,
ab100699
,
ab100699
,
Cyclic AMP ELISA Kit
,
Cayman Chemical
,
581001
,
581001
, Imprint Chromatin Immunoprecipitation Kit Protocol,Merck,CHP1,CHP1,CHP1 List of chemical
(5)
Mitochondrial membrane junction-mediated ATP channeling drives activity-dependent glucose metabolism
bioRxiv
December 19, 2025
Dengbao Yang, Gemma Molinaro, Nadine Nijem, Chuanhai Zhang, Dylen Penny, Meijuan Bai, Mei-Jung Lin, Xiaodong Wen, Salvador Pena, Janaka Wansapura,
et al.
The cAMP levels of
brown adipocytes
were then measured using a
Cyclic AMP ELISA kit
(
Cayman Chemical
,
581001
) following manufacturer’s protocol. To
inhibit
cAMP hydrolysis, 250 μM 3-isobutyl-1-methylxanthine (IBMX)
(6)
Impaired cAMP–PKA–CREB1 signalling drives mitochondrial dysfunction in skeletal muscle during cancer cachexia
Nature Metabolism
November 12, 2025
Elia Angelino, Lorenza Bodo, Roberta Sartori, Valeria Malacarne, Beatrice D’Anna, Nicolò Formaggio, Suvham Barua, Tommaso Raiteri, Andrea Lauria, Simone Reano,
et al.
ether and lyophilized. cAMP content was detected with the
Cyclic AMP ELISA Kit
(
Cayman Chemical
; item
581001
) according to the manufacturer’s protocol. cAMP quantification was normalized over milligram of tissue
(7)
The free fatty acid receptor GPR164 maintains intestinal homeostasis and barrier function
EMBO Reports
October 28, 2025
Takako Ikeda, Yuki Masujima, Keita Watanabe, Akari Nishida, Mayu Yamano, Miki Igarashi, Nobuo Sasaki, Hironori Katoh, Ikuo Kimura
transcriptase,
Invitrogen
,
28025013
3-isobutyl 1-methylxantine,Sigma,28822-58-4 cAMP EIA kit,
Cayman Chemical
,
581001
Folskolin,Sigma,66575-29-9 Crystal violet,Wako,031-04852 Alexa Fluor 488,
Invitrogen
,
A11008
"Goat
(8)
The Legionella pneumophila Dot/Icm Type IV Secretion System is Structurally and Functionally Resilient in Absence of Species-specific Proteins Dis2 and Dis3
Journal of Molecular Biology
October 1, 2025
Jacquelyn R. Roberts, Arwen E. Frick-Cheng, Henry J. Styron, Clarissa L. Durie, Louise Chang, Melanie D. Ohi
infected U937
macrophages
was measured using a cAMP ELISA (
Cayman Chemical
Cyclic AMP ELISA kit
, Item No.
581001
) performed according to manufacturer’s instructions. To prepare cell lysate all excess PBS was removed
(9)
Specific GPCRs Elicit Unique Extracellular Vesicle MiRNA Array Signatures: An Exploratory Study
bioRxiv
June 21, 2025
Xiao Shi, Michelle C. Palumbo, Sheila Benware, Jack Wiedrick, Sheila Markwardt, Aaron J Janowsky
10 min before CCPA addition. cAMP accumulation was measured using cAMP EIA kit from
Cayman Chemical
(
581001
, Ann Arbor, MI), according to the manufacturer’s instructions. All the experiments were conducted with
(10)
Acute regulation of murine adipose tissue lipolysis and insulin resistance by the TGFβ superfamily protein GDF3
Nat Commun
May 13, 2025
Nagasuryaprasad Kotikalapudi, Deepti Ramachandran, Daniel Vieira, William B. Rubio, Gregory R. Gipson, Luca Troncone, Kylie Vestal, David E. Maridas, Vicki Rosen, Paul B. Yu,
et al.
were lysed of 0.1 M HCl. Determination of cAMP was performed using cAMP ELISA Kit (
Cayman chemicals
, #
581001
) following the manufacturer’s instructions. Generation of dual reporter cells Immortalized iWAT-SVF
(11)
A novel phosphodiesterase inhibitor for the treatment of chronic liver injury and metabolic diseases
Hepatology
April 1, 2025
Dalton W. Staller, Sanjali S. Panigrahi, Yahani P. Jayasinghe, Yuxiang Dong, Sohan Mahto, Virender Kumar, Donald R. Ronning, Ram I. Mahato
hydroxyproline concentrations were measured with the
Cyclic AMP ELISA Kit
(
Cayman Chemicals
Item No.
581001
) and Hydroxyproline Colorimetric Assay Kit (
Abcam
ab222941
) according to the manufacturer’s instructions. 2.15
(12)
PDE4 inhibitor rolipram represses hedgehog signaling via ubiquitin-mediated proteolysis of GLI transcription factors to regress breast cancer
The Journal of biological chemistry
March 1, 2025
Bagchi A, Bhattacharya A, Bera A, Basak D, Chatterji U, Biswas A.
triplicate samples per treatment group. The
assay
kit was obtained from
Cayman Chemicals
(item no.:
581001
), and the
assay
was performed following the manufacturer’s protocol after washing the cells with 1X
(13)
SPTLC3 regulates plasma membrane sphingolipid composition to facilitate hepatic gluconeogenesis
Cell Reports
December 24, 2024
David Montefusco, Maryam Jamil, Daniel Canals, Siri Saligrama, Yang Yue, Jeremy Allegood, L. Ashley Cowart
by BCA, and then samples were stored at −80°C. Measurements were performed with an ELISA kit (
Cayman
581001
).
Plasma membrane
isolation Partially purified
plasma membrane
extracts were generated based on Suski
(14)
Investigating the crosstalk between ABCC4 and ABCC5 in 3T3-L1 adipocyte differentiation
Frontiers in Molecular Biosciences
December 9, 2024
Ankit P. Laddha, Aniket Wahane, Raman Bahal, José E. Manautou
intracellular cAMP levels Intracellular cAMP levels were analyzed using a cAMP ELISA kit (Catalog:
581001
,
Cayman Chemical
, Ann Arbor, MI). 2 × 105 cells were seeded in 12 well plates. After 48 h of the last
(15)
Revisiting the follicle-stimulation hormone receptor expression and function in human myometrium and adipose tissue
Molecular Medicine
December 4, 2024
Ewelina Palak, Donata Ponikwicka-Tyszko, Kamila Pulawska-Moon, Maria Sztachelska, Gabriela Milewska, Beata Modzelewska, Tomasz Kleszczewski, Maria L. Koivukoski, Piotr Bernaczyk, Hady Razak Hady,
et al.
FSH-stimulated cAMP production was evaluated using a
cyclic AMP ELISA Kit
(
Cayman Chemical
, MI, USA, cat. no.
581001
). RNA isolation and
gene expression
Total RNA was extracted from the cells using the TRIzol/chloroform
(16)
Membrane progesterone receptors mediate progesterone-stimulated glycogenolysis in the bovine uterine epithelium
Reproduction
December 1, 2024
Malia D Berg, Matthew Dean
was imaged using FluorChem M (Protein Simple, CA, USA). cAMP ELISA A cyclic AMP (cAMP) ELISA kit (
581001
,
Cayman Chemical Company
) was used to determine the level of cAMP in BUTE cells. The manufacturer’s
(17)
MSCs-derived HGF alleviates senescence by inhibiting unopposed mitochondrial fusion-based elongation in post-acute kidney injury
Stem cell research & therapy
November 19, 2024
Zhuang K, Wang W, Zheng X, Guo X, Xu C, Ren X, Shen W, Han Q, Feng Z, Chen X,
et al
.
supernatants were used to
measure
intracellular cyclic AMP (cAMP) levels using the cAMP ELISA Kit (
581001
,
Cayman Chemical
) following the manufacturer's instructions. Measurement of HGF secretion Briefly,
(18)
CFTR Inhibitors Display Antiviral Activity against Herpes Simplex Virus
Viruses
August 16, 2024
Ping Jiang, Zhong Dai, Chan Yang, Liqiong Ding, Songshan Li, Xinfeng Xu, Chen Cheng, Jinshen Wang, Shuwen Liu
purchased from Rising Biotechnology Co., LTD (Quanzhou, Fujian, China). The
Cyclic AMP ELISA Kit
(Item No.
581001
) was purchased from
Cayman Chemical
(Ann Arbor, MI, USA). A
SGK1 Kinase Enzyme System
was purchased
(19)
Phosphodiesterase Inhibition to Sensitize Non-Small-Cell Lung Cancer to Pemetrexed: A Double-Edged Strategy
Cancers
July 6, 2024
Ivanina Foureau AV, Foureau DM, McHale CC, Guo F, Farhangfar CJ, Mileham KF.
concentration of cAMP/cGMP was determined using a cAMP/cGMP kit according to manufacturer’s recommendations (#
581001
/#
581021
,
Cayman
Biochemical, Ann Arbor, MI, USA). In brief, samples were acetylated using 4 M KOH and
(20)
Baicalin reduces chronic stress-induced breast cancer metastasis via directly targeting β2-adrenergic receptor
Journal of Pharmaceutical Analysis
July 1, 2024
Qi Jia, Yinyin Zhou, Li Song, Ximeng Shi, Xuan Jiang, Ruizhi Tao, Aiyun Wang, Yuanyuan Wu, Zhonghong Wei, Yinan Zhang,
et al.
quantification Intracellular levels of cAMP were quantified colorimetrically using a cAMP ELISA kit (No.
581001
,
Cayman Chemical
, Ann Arbor, MI, USA). Results are presented as pmol of cAMP per mL of protein. To determine
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
Cyclic AMP ELISA Kit from Cayman Chemical
Supplier Page
View Company Product Page
$1,586.00
Product Specs
Company Info
Citations
Reviews
Back To Top