Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Assay Kits
Assay Kit
JC-10 Mitochondrial Membrane Potential Assay Kit (Flow Cytometry)
JC-10 Mitochondrial Membrane Potential Assay Kit (Flow Cytometry) from Abcam
Be the first to write a review!
Citations:
(13)
Supplier Page
Supplier Page from
Abcam for
JC-10 Mitochondrial Membrane Potential Assay Kit (Flow Cytometry)
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
JC-10 Mitochondrial Membrane Potential Assay Kit (Flow Cytometry)
Company
Abcam
Price
Supplier Page
View Company Product Page
Catalog Number
ab112133
Quantity
100 Test
Method
Flow Cyt
Sample Type
Adherent cells, Suspension cells
Assay Time
0h 20m
Add to Compare List
Abcam
Discovery Drive
Cambridge Biomedical Campus
Cambridge
CB2 0AX
United Kingdom
Phone
: +44 (0) 1223 696000 (option 1)
+44 (0) 1223 696000 (option 2)
+44 (0) 1223 771600
Company Profile
Website:
http://www.abcam.com
Citations (13)
(1)
Apoptotic Events in Type-I Glanzmann Thrombasthenia Platelets
International Journal of Hematology-Oncology and Stem Cell Research
October 20, 2025
Ehsan Shahverdi, Corinna Petz, Turadj Hemmati, Alireza Farsinezhad, Ali Heidari, Mohammad Faranoush
potential-sensitive dye JC-10, enhanced 5,5’,6,6’-tetrachloro-1,1’,3,3’-tetraethylbenzimidazolcarbocyanine iodide (
AB112133
,
Abcam
, Cambridge Science Park, Cambridge, England), was used to assess depolarization of the mitochondrial
(2)
PKCδ Regulates DNA Damage and Cell Death through a SIRT6/Nrf2-dependent Antioxidant Response
Molecular Cancer Research
September 4, 2025
Trisiani Affandi, Angela M. Ohm, Jordan T. Speidel, M. Cecilia Caino, Dillon P. Boulton, Mary E. Reyland
min. To
measure
mitochondrial membrane
potential (MMP), cells were incubated with JC-10 dye (1X, Cat #
ab112133
,
Abcam
) for 30 min, collected using trypsin, washed, and resuspended in PBS to produce single cell suspension.
(3)
PKCδ regulates DNA damage and cell death through a SIRT6/Nrf2-dependent antioxidant response
Mol Cancer Res
September 4, 2025
Trisiani Affandi, Angela M. Ohm, Jordan T. Speidel, M. Cecilia Caino, Dillon P. Boulton, Mary E. Reyland
min. To
measure
mitochondrial membrane
potential (MMP), cells were incubated with JC-10 dye (1X, Cat #
ab112133
,
Abcam
) for 30 min, collected using trypsin, washed, and resuspended in PBS to produce single cell suspension.
(4)
The cryoprotective effects of celastrol nanoemulsion on post-thawed attributes and fertilizing ability of cryopreserved buffalo semen
Vet Res Commun
June 5, 2025
Wael A. Khalil, Salwa A. Elkhamy, Mohamed M. Hegazy, Mahmoud A. E. Hassan, Sameh A. Abdelnour, Mostafa A. El-Harairy
were washed with PBS and analyzed for
mitochondrial membrane
potential (MMP) using a JC-10
assay
kit (
ab112133
;
Abcam
Company), following the manufacturer’s instructions. Approximately 1 × 106
sperm
cells per milliliter
(5)
Oxidized Cell-Free Hemoglobin Induces Mitochondrial Dysfunction by Activation of the Mitochondrial Permeability Transition Pore in the Pulmonary Microvasculature
Microcirculation
May 20, 2025
Kyle J. Riedmann, Jamie E. Meegan, Aqeela Afzal, Yatzil Cervantes-Cruz, Sarah Obeidalla, Avery M. Bogart, Lorraine B. Ware, Ciara M. Shaver, Julie A. Bastarache
were treated and harvested as described above before being resuspended in 1× JC10 in
assay
buffer (
ab112133
;
Abcam
, Cambridge, MA) and incubated at 37°C for 30 min prior to analysis on an LSRFortessa using the
(6)
Cardamonin suppresses mTORC1/SREBP1 through reducing Raptor and inhibits de novo lipogenesis in ovarian cancer
PLoS One
May 2, 2025
Peiguang Niu, Danyun Li, Huajiao Chen, Yanting Zhu, Jintuo Zhou, Jinhua Zhang, Ying Liu
potential (MMP) measurement MMP was evaluated using the JC-10 Mitochondrial Membrane Potential Assay Kit (
ab112133
;
Abcam
). Treat with cardamonin for 48 h, cells were collected and washed with cold PBS twice. 5 × 105
(7)
Mutational burden of XPNPEP3 leads to defects in mitochondrial complex I and cilia in NPHPL1
iScience
August 18, 2023
Tong L, Rao J, Yang C, Xu J, Lu Y, Zhang Y, Cang X, Xie S, Mao J, Jiang P.
"
MitoSOX™ Red Mitochondrial Superoxide Indicator, for live-cell imaging
",
Invitrogen
,Cat#
M36008
JC-10 Mitochondrial Membrane Potential Assay Kit (Flow Cytometry
),
Abcam
,Cat#
ab112133
CellTiter-Glo Luminescent Cell Viability Assay
,
Promega
,Cat#
G7571
Reverse transcription kit,
Takara
,Cat#
6110A
Cell
(8)
Optimized allotopic expression of mitochondrial ND6 transgene restored complex I and apoptosis deficiencies caused by LHON-linked ND6 14484T > C mutation
Journal of biomedical science
August 3, 2023
Wang J, Ji Y, Ai C, Chen JR, Gan D, Zhang J, Mo JQ, Guan MX.
potential
Mitochondrial membrane
potential was measured with a JC-10 Mitochondrial Membrane Potential Assay Kit (
ab112133
,
Abcam
, Cambridge, United Kingdom), according to the manufacturer’s general recommendations, with some
(9)
Effects of the PARP Inhibitor Olaparib on the Response of Human Peripheral Blood Leukocytes to Bacterial Challenge or Oxidative Stress
Biomolecules
June 4, 2022
Santos SS, Brunialti MKC, Rodrigues LOCP, Liberatore AMA, Koh IHJ, Martins V, Soriano FG, Szabo C, Salomão R.
Mitochondrial Membrane
Potential (MMP) Measurement MMP was measured by
flow cytometry
using a JC-10
Assay
Kit (
ab112133
;
Abcam
). PBMCs (2.5 × 106/mL)were incubated in nonadherent tubes in a 5% CO2 incubator at 37 °C with
(10)
Inhibition of nuclear factor (erythroid-derived 2)-like 2 promotes hepatic progenitor cell activation and differentiation
npj Regenerative Medicine
December 1, 2021
Francesco Bellanti et al.
(
BioLegend
,
424101
) for 15 min, at RT.
Mitochondrial membrane
potential was analyzed using JC-10 (
Abcam
,
ab112133
) as a probe. In all, 5.0 × 105 cells were incubated with JC-10 for 15 min at 37 °C in the dark before
(11)
Cisplatin Activates the Growth Inhibitory Signaling Pathways by Enhancing the Production of Reactive Oxygen Species in Non-small Cell Lung Cancer Carrying an EGFR Exon 19 Deletion
Cancer Genomics - Proteomics
March 12, 2021
MD MOHIUDDIN, KAZUO KASAHARA
evaluation. The MMP was evaluated using the
JC-10 Mitochondrial Membrane Potential Assay Kit-Flow Cytometry
(
ab112133
;
Abcam
). Cells were seeded in 75-cm2 flasks (Falcon, USA), treated as indicated in the results, trypsinized,
(12)
Characterization of Pathogenesis and Inflammatory Responses to Experimental Parechovirus Encephalitis
Frontiers in immunology
January 1, 2021
Jan MW, Su HL, Chang TH, Tsai KJ.
with PeV-A3 at MOI = 1 for 24 h. After
infection
, cells were harvested for JC-10 analysis (
Abcam
, #
ab112133
, Cambridge, England). Cells were suspended in 500 µl of JC-10 solution and incubated at 37°C for 45
(13)
Targeting TRAP1 as a downstream effector of BRAF cytoprotective pathway: a novel strategy for human BRAF-driven colorectal carcinoma
Oncotarget
September 8, 2015
Condelli V, Maddalena F, Sisinni L, Lettini G, Matassa DS, Piscazzi A, Palladino G, Amoroso MR, Esposito F, Landriscina M.
potential was detected by using
JC-10 Mitochondrial Membrane Potential Assay Kit – Flow Cytometry
(
Abcam
,
ab112133
). Cells were seeded into 6-well plates, treated as indicated in the Results, trypsinized, washed with
<<
<
>
>>
Reviews
Be the First to Write a Review!
JC-10 Mitochondrial Membrane Potential Assay Kit (Flow Cytometry) from Abcam
Supplier Page
View Company Product Page
Product Specs
Company Info
Citations
Reviews
Back To Top