Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Articles
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Multimedia
Biocompare Webinars
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Tech Talks
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Resources
Promotions
Events
AACR SPOTLIGHT
Register
Sign In
Biocompare
Products
Assay Kits
Assay Kit
JC-10 Mitochondrial Membrane Potential Assay Kit (Microplate)
JC-10 Mitochondrial Membrane Potential Assay Kit (Microplate) from Abcam
Be the first to write a review!
Citations:
(20)
Supplier Page
Supplier Page from
Abcam for
JC-10 Mitochondrial Membrane Potential Assay Kit (Microplate)
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
JC-10 Mitochondrial Membrane Potential Assay Kit (Microplate)
Company
Abcam
Price
Supplier Page
View Company Product Page
Catalog Number
ab112134
Method
FuncS
Quantity
5 96TESTS
Sample Type
Adherent cells, Suspension cells
Assay Time
1h 0m
Applications
Cellular Assay
Detection Target
Mitochondrial Membrane Potential
Add to Compare List
Abcam
Discovery Drive
Cambridge Biomedical Campus
Cambridge
CB2 0AX
United Kingdom
Phone
: +44 (0) 1223 696000 (option 1)
+44 (0) 1223 696000 (option 2)
+44 (0) 1223 771600
Company Profile
Website:
http://www.abcam.com
Citations (20)
(1)
Mesenchymal stromal cells secretome restores bioenergetic and redox homeostasis in human proximal tubule cells after ischemic injury
Stem Cell Res Ther
December 10, 2023
João Faria, Sandra Calcat-I-Cervera, Renata Skovronova, Bonnie C. Broeksma, Alinda J. Berends, Esther A. Zaal, Benedetta Bussolati, Timothy O'Brien, Silvia M. Mihăilă, Rosalinde Masereeuw
potential (Δψ) The integrity of
mitochondrial membrane
potential (Δψ) was measured using JC-10 (
Abcam
,
ab112134
) [39]. ciPTECs were rinsed once with HBSS and incubated with 50 μl of JC-10 loading solution for 30
(2)
Development of an iron overload HepG2 cell model using ferrous ammonium citrate
Sci Rep
December 8, 2023
Usama Abbasi, Srinivas Abbina, Arshdeep Gill, Jayachandran N. Kizhakkedathu
DCFDA/H2DCFDA ROS generation kit (
ab113851
) and the JC-10 mitochondrial membrane potential assay kit (
ab112134
) were purchased from
Abcam
, while the MTT assay kit was purchased from ATCC (20-1010K).
Cell culture
HepG2 cells
(3)
The DNA damage response in advanced ovarian cancer: functional analysis combined with machine learning identifies signatures that correlate with chemotherapy sensitivity and patient outcome
British journal of cancer
May 1, 2023
Walker TDJ, Faraahi ZF, Price MJ, Hawarden A, Waddell CA, Russell B, Jones DM, McCormick A, Gavrielides N, Tyagi S,
et al
.
1.7. Intra-explant
mitochondrial membrane
function Explant
mitochondrial membrane
potential was assayed by JC-10 (
ab112134
,
Abcam
) upon live-
cell cultures
. Cells were seeded at 25,000 cells per well and incubated with a 5-point
(4)
IL-17A promotes lung fibrosis through impairing mitochondrial homeostasis in type II alveolar epithelial cells
Journal of cellular and molecular medicine
November 1, 2022
Xiao H, Peng L, Jiang D, Liu Y, Zhu L, Li Z, Geng J, Xie B, Huang X, Wang J,
et al
.
in relative MMP were measured using the
JC‐10 Mitochondrial Membrane Potential Assay Kit‐Microplate
(
ab112134
,
Abcam
, Cambridge, UK) according to the manufacturer's instructions. Briefly, 5 × 104 cells/well were
(5)
Complement membrane attack complex is an immunometabolic regulator of NLRP3 activation and IL-18 secretion in human macrophages
Frontiers in Immunology
September 27, 2022
Gisela Jimenez-Duran, Joseph Kozole, Rachel Peltier-Heap, Eleanor R. Dickinson, Christopher R. Kwiatkowski, Francesca Zappacosta, Roland S. Annan, Nicholas W. Galwey, Eva-Maria Nichols, Louise K. Modis,
et al.
Assays
,Critical Commercial
Assays
JC-10 Mitochondrial Membrane Potential Assay Kit – Microplate
,
Abcam
,
ab112134
Amplex Red Hydrogen Peroxide/Peroxidase Assay Kit
,
Invitrogen
,
A22188
Cell-TiterGlo kit,
Promega
,
G7571
Calcein
(6)
ZnT8 loss-of-function accelerates functional maturation of hESC-derived β cells and resists metabolic stress in diabetes
Nature communications
July 16, 2022
Ma Q, Xiao Y, Xu W, Wang M, Li S, Yang Z, Xu M, Zhang T, Zhang ZN, Hu R,
et al
.
seeded onto 3.5 cm Matrigel-coated glass-bottom petri dishes for 24 h and loaded with JC-10 (
Abcam
, #
ab112134
, 10 mg ml−1) for 1 h. During the period of JC-10
staining
, several dishes of HUES8 SC-β cells were treated
(7)
Growth Differentiation Factor 15 Protects SH-SY5Y Cells From Rotenone-Induced Toxicity by Suppressing Mitochondrial Apoptosis
Frontiers in Aging Neuroscience
June 2, 2022
Peizheng Li, Hongbo Lv, Bohan Zhang, Ruonan Duan, Xiufang Zhang, Pengfei Lin, Chengyuan Song, Yiming Liu
Potential Measurements To evaluate the
mitochondrial membrane
potential (MMP), we used a JC-10
assay
kit (
ab112134
,
Abcam
). Following the commercial protocols, cells were cultured in a 96-well black plate with a transparent
(8)
A Synthetic Small RNA Homologous to the D-Loop Transcript of mtDNA Enhances Mitochondrial Bioenergetics
Frontiers in Physiology
April 6, 2022
Theodore L. Mathuram et al.
Mitochondrial membrane
potential was measured using a JC-10 mitochondrial membrane potential assay kit (
Abcam
, cat. #
ab112134
) according to the manufacturer’s instructions. The results were read by a BioTek Synergy HT spectrophotometer. Preparation
(9)
Cannabinol inhibits oxytosis/ferroptosis by directly targeting mitochondria independently of cannabinoid receptors
Free Radical Biology and Medicine
February 1, 2022
Zhibin Liang, David Soriano-Castell, Devin Kepchia, Brendan M. Duggan, Antonio Currais, David Schubert, Pamela Maher
from
Thermo Fisher Scientific
(Waltham, MA). JC-10 Mitochondrial Membrane Potential Assay Kit (Cat#
ab112134
) was from
Abcam
(Burlingame, CA). Criterion XT Bis-Tris Protein Gradient Gel (Ca#
3450125
),
XT MOPS Running Buffer
(10)
Chemically induced senescence in human stem cell-derived neurons promotes phenotypic presentation of neurodegeneration
Aging cell
January 1, 2022
Fathi A, Mathivanan S, Kong L, Petersen AJ, Harder CRK, Block J, Miller JM, Bhattacharyya A, Wang D, Zhang SC.
mode.
Mitochondrial membrane
potential
assay
was performed using JC‐10 mitochondrial membrane potential assay kit (
ab112134
,
Abcam
). H9‐derived Cortical
neuron
progenitors and 298G and 298S
hiPSC
‐derived MN progenitors were
(11)
Alternative mitochondrial quality control mediated by extracellular release
Autophagy
October 1, 2021
Choong CJ, Okuno T, Ikenaka K, Baba K, Hayakawa H, Koike M, Yokota M, Doi J, Kakuda K, Takeuchi T,
et al
.
assay
Mitochondrial membrane
potential
assay
was performed using the cationic dye JC10, and an
assay
kit (
Abcam
,
ab112134
), following the manufacturer’s protocol.
Confocal
images of JC10 stained cells were acquired on same
(12)
Alcohol-abuse drug disulfiram targets pediatric glioma via MLL degradation
Cell death & disease
August 11, 2021
Meier S, Cantilena S, Niklison Chirou MV, Anderson J, Hargrave D, Salomoni P, de Boer J, Michod D.
reader.
Mitochondrial membrane
potential
assay
JC-10
Mitochondrial Membrane
Potential
Assay
(
Abcam
,
ab112134
) was used according to the manufacturer’s protocol.
Luminescence
was measured using a TECAN infinite
(13)
Hypoxia-induced mitochondrial abnormalities in cells of the placenta
PloS one
January 1, 2021
Vangrieken P, Al-Nasiry S, Bast A, Leermakers PA, Tulen CBM, Janssen GMJ, Kaminski I, Geomini I, Lemmens T, Schiffers PMH,
et al
.
potential
Mitochondrial membrane
potential was assessed as instructed by the manufacturer’s protocol (JC-10
assay
kit,
ab112134
,
Abcam
, Cambridge, Massachusetts, USA) according to the manufacturer’s protocol. Briefly, BeWo cells
(14)
Retrograde signaling by a mtDNA-encoded non-coding RNA preserves mitochondrial bioenergetics
Communications biology
October 30, 2020
Blumental-Perry A, Jobava R, Bederman I, Degar AJ, Kenche H, Guan BJ, Pandit K, Perry NA, Molyneaux ND, Wu J,
et al
.
assays
Mitochondrial membrane
potential was measured using the JC-10 Mitochondrial Membrane Potential Assay Kit (
ab112134
,
Abcam
, USA) according to the manufacturer’s instructions. Results were read by a Biotek Synergy HT
(15)
Dietary magnesium supplementation improves lifespan in a mouse model of progeria
EMBO Molecular Medicine
October 7, 2020
Ricardo Villa‐Bellosta
potential (ΔΨm) measurement The ΔΨm was assessed by plate reader using a fluorescent probe (JC‐10;
ab112134
,
Abcam
) by following the manufacturer's instruction. When
mitochondria
are polarized electrically, JC‐10
(16)
12(S)-HETE mediates diabetes-induced endothelial dysfunction by activating intracellular endothelial cell TRPV1
The Journal of clinical investigation
September 1, 2020
Otto M, Bucher C, Liu W, Müller M, Schmidt T, Kardell M, Driessen MN, Rossaint J, Gross ER, Wagner NM.
function.
Mitochondrial membrane
potential was assessed using the JC-10 mitochondrial membrane potential assay kit (
ab112134
,
Abcam
) and a BD Accuri
flow cytometer
or by life cell imaging after loading of cells with 150 nM tetramethylrhodamine
(17)
Maternally Inherited Diabetes Mellitus Associated with a Novel m.15897G>A Mutation in Mitochondrial tRNA
Thr
Gene
Journal of diabetes research
January 1, 2020
Li K, Wu L, Liu J, Lin W, Qi Q, Zhao T.
Mitochondrial Membrane
Potential Measurement A JC-10
Mitochondrial Membrane
Potential
Microplate Assay
Kit (
Abcam
,
ab112134
) was utilized based on the provided protocols, as in the previous studies, as a means of assessing the
(18)
1-Trifluoromethoxyphenyl-3-(1-propionylpiperidin-4-yl) Urea, a Selective and Potent Dual Inhibitor of Soluble Epoxide Hydrolase and p38 Kinase Intervenes in Alzheimer's Signaling in Human Nerve Cells
ACS chemical neuroscience
September 18, 2019
Liang Z, Zhang B, Xu M, Morisseau C, Hwang SH, Hammock BD, Li QX.
(Cat#
5000002
) was from
Bio-Rad
(Hercules, CA). JC-10 Mitochondrial Membrane Potential Assay Kit (Cat#
ab112134
) was from
Abcam
(Burlingame, CA). TransAM NF-κB Family ELISA Assay Kit (Cat# 43296) was from Active
(19)
Molecular mechanism of cardol, isolated from Trigona incisa stingless bee propolis, induced apoptosis in the SW620 human colorectal cancer cell line
BMC Pharmacology and Toxicology
December 1, 2017
Paula Mariana Kustiawan, Kriengsak Lirdprapamongkol, Tanapat Palaga, Songchan Puthong, Preecha Phuwapraisirisan, Jisnuson Svasti, Chanpen Chanchao
mitochondrial membrane
polarization was measured using a JC-10 mitochondrial membrane potential assay kit (catalog #
ab112134
,
Abcam
, Cambridge, MA) according to the manufacturer’s instructions. SW620 cells were seeded (8 x 104
(20)
Aminoglycoside stress together with the 12S rRNA 1494C>T mutation leads to mitophagy
PloS one
January 1, 2014
Yu J, Zheng J, Zhao X, Liu J, Mao Z, Ling Y, Chen D, Chen C, Hui L, Cui L,
et al
.
for 24 hours. Then, following the manufacturer’s instructions, treatment with the JC-10 kit (
Abcam
,
ab112134
) was performed as follows: 50 µl of JC-10 was added per well, followed by
incubation
for 1 hour before
<<
<
>
>>
Reviews
Be the First to Write a Review!
JC-10 Mitochondrial Membrane Potential Assay Kit (Microplate) from Abcam
Supplier Page
View Company Product Page
Product Specs
Company Info
Citations
Reviews
Back To Top