Description
Description: Assess the mitochondrial permeability transition event in living cell samples with the MitoPT JC-1 Assay Kit. ICT's MitoPT JC-1 assay utilizes a well-characterized, lipophilic, but slightly cationic fluorescent dye, JC-1, to detect mitochondrial membrane depolarization. This fluorescence-based, whole cell assay allows for the easy distinction between non-apoptotic cells and cells with membrane-permeant mitochondria. The MitoPT JC-1 assay can be used in conjunction with existing apoptosis or metabolic stress protocols. Each kit includes the JC-1 potentiometric mitochondrial dye, a wash buffer for removing any excess JC-1 dye after staining, and the generic mitochondrial membrane depolarizer Carbonylcyanide m- chlorophenylhydrazone (CCCP) for positive controls. MitoPT JC-1 stained cells can be analyzed using flow cytometry, fluorescence microscopy, and fluorescence plate reader evaluation methodology.
Background: Detect Mitochondrial Depolarization with MitoPT As a member of the carbocyanine family of potentiometric dyes, 5,5',6,6'- tetrachloro- 1,1',3,3'- tetraethylbenzimidazolocarbocyanine I- / Cl- salt, commonly known as JC-1, is categorized as a slow membrane redistribution dye. The lipophilic structure of this dye allows it to easily penetrate cell and mitochondrial lipid bilayer membrane barriers. Once inside, JC -1 will redistribute itself within healthy polarized mitochondria in a Nernstian manner. As this dye accumulates within the negatively charged mitochondrial organelles, it reaches a saturation level at which J-aggregate formation occurs. This precipitated or aggregated form of the JC-1 dye fluoresces orange- red with blue light (488 nm) excitation. When the mitochondrial membrane potential collapses in apoptotic or metabolically stressed cells, the MitoPT JC-1 reagent will no longer concentrate within the mitochondria. Instead, it is dispersed throughout the cell in a monomeric form. In the monomer form, JC- 1 will emit a green fluorescence upon excitation at 488 nm. The MitoPT JC-1 assay can be used in conjunction with existing apoptosis or metabolic stress protocols. Each kit includes the JC-1 potentiometric dye reagent, a 10X wash buffer for removing any excess JC-1 dye after staining, and the generic mitochondrial membrane depolarizer Carbonylcyanide m- chlorophenylhydrazone (CCCP). JC-1 stained cells can be analyzed using flow cytometry, fluorescence microscopy, and fluorescence plate reader evaluation methodology