Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
Antibody Discovery
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Troubleshooting and Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Supplies & Consumables
D1000 ScreenTape
Supplier Images
Published Figures
D1000 ScreenTape
D1000 ScreenTape from Agilent Technologies
Be the first to write a review!
Citations:
(>1k)
Figures:
(13)
Supplier Page
Supplier Page from
Agilent Technologies for
D1000 ScreenTape
Get Pricing
Description
For the analysis of DNA from 35 to 1000 bp. Includes 7 ScreenTape devices, sufficient for 112 samples. Should be ordered in conjunction with 5067-5583 and optionally 5067-5586.
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
D1000 ScreenTape
Company
Agilent Technologies
Price
Supplier Page
View Company Product Page
Catalog Number
5067-5582
Time
16 samples < 20 min
96 samples < 90 min
Accuracy
±20 %
Sample Volume
1 µL
Sensitivity
0.1 ng/µL
Resolution
300-1000 bp: 10 %
35-300 bp: 15 %
Range
35 to1000 bp
Features
Uses per ScreenTape: 16
Add to Compare List
Agilent Technologies
5301 Stevens Creek Blvd
Santa Clara
,
California
95051
United States
Phone
: +1 877-424-4536
Company Profile
Website:
www.agilent.com
Citations (2969)
(1)
Longitudinal gut microbiome dynamics are associated with clinical outcome and toxicity during ibrutinib therapy
Gut Microbes
December 31, 2026
Nadine Morineau, Benoît Tessoulin, Thomas Guimard, Mathilde Papin, Antoine Roquilly, Steven Le Gouill, Emmanuel Montassier
20060060
). Library quality and fragment size distribution were assessed using an Agilent High
Sensitivity
D1000 ScreenTape
assay
(
Agilent
; catalog no.
5067-5584
). Libraries were pooled at equimolar concentrations and sequenced
(2)
rAAV-mediated multi-miRNA delivery targeting MAPK pathway suppresses laser-induced choroidal neovascularization in mice
Molecular Therapy Nucleic Acids
December 8, 2026
Jung Woo Han, Jin Young Yang, Yeji Kim, Sumin An, Eunjae Yoo, In Hwan Park, Sang-Won Lee, Hyun-Ji Lee, Tae Geol Lee, Wook Hyun Jung,
et al.
enriched via
PCR
. Final library quality and mean fragment size were determined using the TapeStation HS
D1000 ScreenTape
(
Agilent Technologies
). Library quantification was conducted via
qPCR
using a specialized quantification
(3)
Plant Identity Shapes Core Microbiomes on Green Roofs
Environ Microbiol Rep
October 30, 2026
Katarzyna Larysz, Michał Ludynia, Artur Trzebny, Wiktoria Klencz, Natalia Malcherczyk, Edyta Sierka
concentration and size distribution of the DNA libraries were determined using the High
Sensitivity
D1000 ScreenTape
assay
on the
Agilent 2200 TapeStation
System (
Agilent Technologies
). Clonal
amplification
of the template
(4)
A CD4-lineage erythro-myeloid progenitor within the adult bone marrow defines an alternative pathway for macrophage generation
Nat Immunol
October 26, 2026
Shweta Tikoo, Rohit Jain, Brendon Martinez, Renhua Song, Matthias Wielscher, Carlos Márquez-Burgoa, Anastasiya Hladik, Simone Rizzetto, Lisa E. Shaw, Minoo Ghannadan,
et al.
(Invitrogen, Q33231) and assessed using TapeStation high-
sensitivity
D5000 and D1000 (
Agilent
,
5067-5592
and
5067-5582
, respectively) before
sequencing
on an Illumina NovaSeq 6000 at the Biomedical
Sequencing
Facility at
(5)
Tumor suppressor-like mutations mark a dosage-constrained dependency in leukemia
bioRxiv
October 23, 2026
Jonathan D. Lee, Madison M. Uyemura, Francisca Lamini, Ryan R. Posey, Ellie H. Shin, Amyah C. Harris, Tiziana Ottone, Giulia Cheloni, David B. Chou, Bon Q. Trinh,
et al.
according to the manufacturer’s instructions. Library quality was assessed by TapeStation (High
Sensitivity
D1000 ScreenTape
;
Agilent
), and libraries were pooled and sequenced on a NovaSeq 6000 (Illumina). For NB4 overexpression
(6)
Functional chimeric mRNAs encode proteins in mammalian immunity
Nature
October 22, 2026
Olivia Venezia, Harry Kane, Gang Du, Hannah D. Coughlan, Timothy M. Johanson, Hongshen Wang, Pathricia Tilstam, Samuel W. Kazer, Georgia Gunner, Daisy A. Hoagland,
et al.
were run on the Agilent
4200 Tapestation instrument
, with the corresponding
Agilent
High
Sensitivity
D1000 ScreenTape
assay
to visualize the libraries and check that the size and concentrations of the libraries matched
(7)
Multi-omics analysis of high-grade serous ovarian cancers reveals heterogeneity and distinct immunological patterns based upon clinico-genomic status
PLoS Genet
October 22, 2026
Jing Qian, Rania Bassiouni, Yuxin Jin, Seeta Rajpara, Monica Neuman, Varun U. Khetan, Bodour Salhia, David W. Craig, Joseph W. Carlson, Lynda D. Roman,
et al.
Kit v3 (Takara Bio). Final libraries were evaluated for fragment size and quality using the
Agilent
D1000 ScreenTape
assay
and sequenced on an Illumina NextSeq 2000 P3 flow cell with paired-end 2 × 100 bp reads. FASTQ
(8)
DNA Fragment Length Analysis Using Machine Learning Assisted Vibrational Spectroscopy
ACS Measurement Science Au
October 21, 2026
Rashad Fatayer, Waseem Ahmed, Irene Szeto, Stephen-John Sammut, Ganapathy Senthil Murugan
length distribution for each condition was analyzed using the
Agilent
4200 TapeStation system with HS
D1000 ScreenTape
. ATR-
FTIR
Spectroscopy
ATR-
FTIR
spectra were acquired using an
Agilent
Cary 670 FTIR spectrometer
(9)
SARS-CoV-2 Gamma Variant In Vivo Model Demonstrates Severe Pathogenicity and Unique Transcriptomic Signatures Compared to Alpha, Delta, and Omicron Variants
Microorganisms
October 20, 2026
Fernanda Martins Marim, Paula Luize Camargos Fonseca, Maria Inês Mantuani Pascoaloti, Aryel Beatriz Paz E Silva, Fernanda Gil de de Souza, Érika Donizetti Candido, Vivian Vasconcelos Costa Litwinski, Danielle Bruna Leal Oliveira, Edison Luiz Durigon, Rennan Garcias Moreira,
et al.
Quant
Assay
kit (Qiagen, Hilden, Germany) and average size (300 bp) was verified using High-
Sensitivity
D1000 ScreenTape
reagents (
Agilent Technologies
, Santa Clara, CA, USA). For
RNA sequencing
, three animals out of the
(10)
Integrative Analysis of Whole Exome Sequencing and Gene Expression to Uncover Genetic Mechanisms in Inflammatory Bowel Disease
Genes (Basel)
October 20, 2026
Babajan Banaganapalli, Waad Fahad Alharbi, Wejdan Abdullah Alzahrani, Ashraf A. El-Harouni, Mahmoud Almutadares, Khalidah Khalid Nasser, Omar I. Saadah, Mahmoud Mosli, Ragdah Hussain Arif, Hadeel A. Alsufyani,
et al.
Agilent SureSelectXT library preparation protocol. Library size and quality were checked on a TapeStation
D1000 ScreenTape
(
Agilent Technologies
, Santa Clara, CA, USA). After capture, libraries were quantified by
qPCR
(KAPA
(11)
Spike protein derived from an apathogenic IBV strain confers attenuated phenotype to a nephropathogenic IBV strain
Journal of Virology
October 20, 2026
James Kirk, Samantha Sives, Adam Rayment, Amber Tappin, Sam Jones, Jessica Miles, Chandana Tennakoon, Elizabeth Martin-Drew, Graham Freimanis, Harry Francis,
et al.
processed for tagmentation and
amplification
. Post-tagmentation QC was performed using Tapestation
D1000 screentape
(
Agilent
) and Qubit (Life Technologies). Two pools of three libraries were submitted for capture
hybridization
,
(12)
EZH2-dependent phenotypic plasticity reveals TTP-associated and mTORC1 therapeutic vulnerabilities in lethal prostate cancer
Cell Reports Medicine
October 20, 2026
Beatriz German, Katherine L. Morel, Teia Noel, Nadia Boufaied, Deborah L. Burkhart, Sujun Chen, Felipe Dezem, Xintao Qiu, Henry W. Long, Kun-Lin Ho,
et al.
(#32854, Thermo Fisher Scientific), by an Agilent TapeStation 2200 system using
D1000 ScreenTape
(#
5067–5582
,
Agilent
), and by
RT-qPCR
using the KAPA library quantification kit (# KK4835, Kapa Biosystems), according
(13)
Genome-wide cell-free DNA methylation profiling via TAPS for moyamoya disease diagnosis and postoperative collateral formation prediction
Cell Reports Medicine
October 20, 2026
Tongyu Chen, Zetian Jia, Ying Tang, Jianjian Zhang, Yi Zhang, Xiaojian Li, Jiazhi Jiang, Jin Yu, Tingbao Zhang, Dongliang Guo,
et al.
Quantification Kit for Illumina. Library size and quality were assessed using the High
Sensitivity
D1000 ScreenTape
assay
on an
Agilent
4200 TapeStation system. Final libraries were sequenced on an Illumina NovaSeq 6000
(14)
Glioblastoma immune landscape remodeling following treatment with CD70-targeted CAR-T cells
Oncoimmunology
October 18, 2026
Alexandros Kourtesakis, Dennis Alexander Agardy, Clara Tejido Dierssen, Ling Hai, Dirk Carsten Frieder Hoffmann, Normann Mussnig, Ralph Sinn, Manuel Fischer, Andy Schacht, Michael Breckwoldt,
et al.
Thermo Fisher Scientific
). Library fragment size and overall DNA quality were assessed with the D1000 ScreenTape
Assay
(#
5067-5582
,
Agilent
) loaded on a
4150 TapeStation System
(
Agilent
). Generated libraries were sequenced on a NovaSeq6000
(15)
Benchmarking immunoinformatic repertoire assemblies from bulk RNA-seq and PCR-based V(D)J sequencing using PCR-free SMRT RNA sequencing
iScience
October 16, 2026
Steve Genebrier, Samuel Bastos Serra Trinca, Ophélie Dézé, Marie Cornic, Maiwenn Pineau, Karin Tarte, Michel Cogné
cassette 1.5% agarose 300 pb–1.5 kb,
Sage Science
,Cat# HTC1510
D1000 ScreenTape
,
Agilent Technologies
,Cat#
5067–5582
MiSeq Reagent Kit v3 (600 cycles),Illumina,Cat# MS-102–3003 TruSeq Stranded mRNA
Library Prep
kit,
Illumina
,Cat#
(16)
Trajectory of Lymph Node Metastasis Reflects the Molecular Features of Esophageal Squamous Cell Carcinoma
Cancer Research and Treatment
October 15, 2026
Jiho Park, Seong Yong Park, Ha Eun Kim, Se-Young Jo, Jeongsoo Won, Dae Joon Kim, Sangwoo Kim
Quantification Protocol Guide (#KK4854, KAPA Biosystems) and qualified using the TapeStation
D1000 ScreenTape
(#
5067-5582
,
Agilent Technologies
). Indexed libraries were then subjected to paired-end (2×100 bp)
sequencing
on
(17)
Medullary epithelium-free areas in the rat thymus are specialized niches enriched for mature thymocytes and distinct stromal subsets
Front Immunol
October 14, 2026
Yasushi Sawanobori, Tadayuki Ogawa
quantified using the Qubit dsDNA
Assay
(Thermo Fisher Scientific, Waltham, MA, USA) and TapeStation
D1000 ScreenTape
(
Agilent Technologies
, Santa Clara, CA, USA), and sequenced on a NovaSeq 6000 platform (Illumina, San
(18)
PUS7 mRNA pseudouridylation is driven by RNA sequence, structure, and cell-type-specific features
Cell Genomics
October 14, 2026
Rebecca Rodell, Ronit Jain, Hossein Shenasa, Matias Montes, Nicolas Robalin, Stefan Prodic, Eduardo Eyras, Nicole M. Martinez
with between 20 and 35 cycles.
PCR
success was assessed with TapeStation
D1000 ScreenTape
(
Agilent
#
5067–5582
) to check product size and abundance. DNA was cleaned with AMPure XP beads (
Beckman Coulter
#
A63881
),
(19)
Heat Stress Responses During Grain Filling in Two Korean Wheat Cultivars as Affected by Developmental Stage and Exposure Duration
Plants (Basel)
October 13, 2026
Ju-Young Choi, Junseok Choi, Jae-Han Son, Yurim Kim, Han-Yong Jeong, Jinhee Park, Goeun Lee, Sookjin Kim, Chon-Sik Kang, Chuloh Cho
second-strand cDNA synthesis
. Following adenylation and adapter
ligation
, the resulting libraries were assessed using
D1000 ScreenTape
(
Agilent Technologies
).
Sequencing
was carried out on an Illumina NovaSeq platform (Illumina, Inc.,
(20)
Physiological and transcriptional responses of lactic acid bacteria to sub-inhibitory cadmium exposure
Front Microbiol
October 13, 2026
Diana Vardanyan, Leonardo Mancini, Matteo Bernardi, Pasquale Filannino, Francesco Maria Calabrese, Maria De Angelis
Wilmington, MA, USA).
PCR
products were evaluated using
Agilent 2200 TapeStation
electrophoresis
with
D1000 ScreenTape
(
Agilent Technologies
, Santa Clara, CA, USA) to verify
specificity
and expected amplicon size (~150–200
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
D1000 ScreenTape from Agilent Technologies
Supplier Page
View Company Product Page
Product Specs
Company Info
Citations
Reviews
Back To Top