Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
Antibody Discovery
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Troubleshooting and Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
RNA Detection Kits
QuantiFluor RNA System
Supplier Images
QuantiFluor RNA System from Promega
Be the first to write a review!
Citations:
(81)
Supplier Page
Supplier Page from
Promega for
QuantiFluor RNA System
Get Pricing
Description
The QuantiFluor RNA System contains a fluorescent RNA-binding dye that enables sensitive quantitation of small amounts of RNA in solution
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
QuantiFluor RNA System
Company
Promega
Price
$260.00
Supplier Page
View Company Product Page
Catalog Number
E3310
Quantity
1ml
Molecular Weight
~89kDa
Add to Compare List
Promega
2800 Woods Hollow Rd
Madison
,
WI
53711
United States
Phone
: Tel: +1 (608) 274-4330
Fax: +1 (608) 277-2516
Email: custserv@promega.com
techserv@promega.com
Company Profile
Website:
http://www.promega.com
Citations (81)
(1)
Photosynthetic and Antioxidant Responses of Lolium perenne to Aluminum Oxide Nanoparticles, Their Supernatant, and Aluminum Chloride Under Acidic Conditions
Molecules
October 16, 2026
Jorge González-Villagra, Valentina Figueroa, Paz Cárcamo-Fincheira, Marjorie Reyes-Díaz, Gonzalo Tortella Fuentes, Adalberto Benavides-Mendoza, Antonio Juárez-Maldonado, Ricardo Tighe-Neira, Claudio Inostroza-Blancheteau
Quantus® dual-channel fluorometer (Cat. No.
E6150
) using a
Promega
QuantiFluor® dye system (Cat. No.
E3310
). The RNA was treated with RNase-free
DNase I
(
Thermo Fisher
, Waltham, MA, USA) to eliminate genomic
(2)
Growth-dependent tRNA reprogramming and codon bias link translation to metabolic state in Enterococcus faecalis
mBio
October 14, 2026
Michelle M. Mitchener, Caleb M. Anderson, Mark Veleba, Kayla Teo, Mélanie Roch, Ruixi Chen, Yifeng Yuan, Isaiah Han, Agnieszka Dziergowska, Kevin Pethe,
et al.
in the samples was determined to be <10% using QuantiFluor dsDNA and RNA Systems (
Promega
,
E2671
and
E3310
, respectively).
RNA-sequencing
Purified total RNA was processed using the Illumina Stranded Total
(3)
Conserved and Tissue-Specific RNA and Protein Cargos of Small Extracellular Vesicles From 120 Tissue Sites Across 34 Organs in a Single Pig
J Extracell Vesicles
September 29, 2026
Naixiang Yu, Jinxiu Liu, Chenliang Lai, Siyi Liu, Jiacheng Wei, Jiahong Zhong, Sanya Xiong, Qingjie Zeng, Junwu Ma, Zhou Zhang,
et al.
RNA quantification
was performed using the QuantusTM Fluorometer (Promega) with the
QuantiFluor RNA System
solution (
E3310
,
Promega
). RNA integrity was assessed using the Qsep100 automated
electrophoresis
system (BIOptic) with
(4)
Clinical Stage-Specific Alteration of hsa-miR-424-5p in Milk Small Extracellular Vesicles from Bovine Leukemia Virus Infection to Progression of Enzootic Bovine Leukosis
Animals (Basel)
September 22, 2026
Md. Matiur Rahman, Shota Moriyasu, Yuji O. Kamatari, Ayaka Okada, Yasuo Inoshima
(
217184
;
Qiagen
). The concentration of the extracted RNA was determined using a
QuantiFluor RNA System
(
E3310
,
Promega
). cDNA was synthesized from 10 ng of the extracted total RNA using a miRCURY LNA RT Kit (339340;
(5)
Reduced NLRP3, AIM2 and NLRC4 inflammasome activity in cord blood of extremely preterm infants
Front Pediatr
September 8, 2026
Hannah Siedel, Kristin Hieronymus, Jan M. Niehues, Lev Grinstein, Susanne Russ, Avril A. B. Robertson, Matthew A. Cooper, Jennifer L. Winkler, Angela Rösen-Wolff, Stefan Winkler
immediately stored at −80 °C. RNA concentration was measured using the
QuantiFluor RNA System
(
Promega
,
E3310
) with a
Quantus Fluorometer
(
Promega
,
E6150
), and RNA integrity was assessed by
electrophoresis
on a
(6)
Increasing usable reads in RNA-seq protocols
iScience
August 21, 2026
Felix Pförtner, Eva Briem, Wolfgang Enard, Daniel Richter
,
Agilent Technologies
,Cat#
5067-4626
QuantiFluor dsDNA System
,
Promega
,Cat#2670
QuantiFluor RNA System
,
Promega
,Cat#
E3310
NEBNext Ultra II FS
DNA Library Prep
Kit for Illumina,
New England Biolabs
,Cat#
E7805S
NEBNext Ultra II Q5 Master Mix
(7)
Seedless 3' pairing enables miR-17 family miRNAs to seize let-7 target sites
Nucleic Acids Res
August 14, 2026
Artur Laski, Anneke Brümmer, Matije Lucic, Elisa Federici, Iris Mestres-Pascual, Jochen Imig, Alexander Kanitz, Mihaela Zavolan, Luca F R Gebert, Ian J MacRae,
et al.
and quantification Total RNA concentration was measured using the
QuantiFluor RNA System
(
Promega
, #
E3310
), and integrity was assessed on the Bioanalyzer (Agilent) using the RNA 6000 Nano Chip (
Agilent
, #
5067-1511
).
(8)
Cellular Dynamics of Transgenic Porcine Endothelial Cells to Inflammatory Stimuli in Xenotransplantation Settings
Xenotransplantation
July 1, 2026
Mitra Gultom, Nina Thomi, Kassandra Teixeira‐Riberio, Jane Shaw, Alain Despont, Nikolai Klymiuk, Elisabeth Kemter, Eckhard Wolf, Robert Rieben
manufacturer's guidelines, followed by quantification of the total RNA with a
Quantifluor RNA system
(
Promega
,
E3310
). Bulk RNA barcoding and
sequencing
(BRB‐seq) was performed by Alithea Genomics, as described previously
(9)
Inter-individual gene expression variability implies stable regulation of brain-biased genes across organs in three ray-finned fishes
bioRxiv
June 1, 2026
Christabel F. Bucao, Consolée Aletti, Alexandre Laverré, Sébastien Moretti, Alexandra Trouvé, Andrew W. Thompson, Brett L. Racicot, Catherine A. Wilson, Julien Bobe, Ingo Braasch,
et al.
Following extraction, RNA concentration was quantified with the
QuantiFluor RNA System
(
Promega
, ref.
E3310
). A subset of samples was also assessed for RNA quality using the 5200 Fragment Analyzer System (
Agilent Technologies
(10)
Impact of organic pollutants on phenotype and gene expression in human breast cancer cells
Journal of Applied Toxicology
May 1, 2026
Camila Confortin, Heloisa Amancio, Jessica Zablocki da Luz, Aliciane de Almeida Roque, Tugstênio Lima de Souza, José Eduardo Vargas, Ciro Alberto de Oliveira Ribeiro, Francisco Filipak Neto
The RNA was quantified by
fluorimetry
(λex/em = 492/540 nm) using the
QuantiFluor RNA System
(Ref.
E3310
[
Promega
]), and the purity was assessed by
spectrophotometry
(λ = 230, 260, and 280 nm) for protein
(11)
Ether phospholipids modulate somatosensory responses by tuning multiple receptor functions in Drosophila
iScience
April 17, 2026
Takuto Suito, Xiangmei Deng, Shoma Sato, Kohjiro Nagao, Christian Ganser, Takayuki Uchihashi, Motosuke Tsutsumi, Tomomi Nemoto, Yuji Hara, Makoto Tominaga,
et al.
Master Mix,Toyobo,FSQ-201
NucleoSpin RNA Plus XS
,
Macherey–Nagel
,740990
QuantiFluor RNA System
,
Promega
,
E3310
Thunderbird Next SYBR qPCR Mix,Toyobo,QPX-201
X-tremeGENE 9 DNA transfection reagent
,
Roche
,
6365787001
TransFectin Lipid Reagent
(12)
Deficiency of Werner RecQ-type DNA helicase causes premature malnutrition in zebrafish
iScience
March 20, 2026
Kota Ujibe, Makoto Kashima, Miku Kataoka, Rintaro Shimada, Masashige Okamoto, Isao Kobayashi, Seiji Wada, Hiroki Matsuda, Akira Sakamoto, Hiromi Hirata
KK3009 KAPA SYBR
FAST qPCR
Kit,KAPA BIOSYSTEMS,Cat# KK4602
QuantiFluor RNA System
Kit,
Promega
,Cat#
E3310
Agilent High
Sensitivity
DNA kit,
Agilent Technologies
,Cat#
5067-4626
QuantiFluor ONE dsDNA System
(13)
Dysbiosis of the enteric DNA virome correlates with the development of cachexia in a murine Lewis lung carcinoma (LLC) model
Archives of Virology
March 1, 2026
David Aciole Barbosa, Yara N.L.F. de Maria, Fabiano B. Menegidio, Regina Costa de Oliveira, Daniela L. Jabes, Luiz R. Nunes
a Quantus fluorimeter, using QuantiFluor dsDNA and RNA System kits (
Promega
, catalog nos.
E2671
and
E3310
). Next, reverse transcription and
amplification
of cDNA were performed using a WTA2 kit (Sigma, catalog
(14)
Polymer-lipid hybrid nanoparticle enhances mRNA delivery and T cell-mediated immunity
bioRxiv
January 29, 2026
Xiaolei Cai, Min Chen, Guoshuai Cao, Nicholas Asby, Derek Elli, Haley Gula, Vlad Nicolaescu, Duy-Thuc Nguyen, Xiaodan Huang, Tanushree Dangi,
et al.
Japan). The mRNA encapsulation efficiency was determined using the
QuantiFluor® RNA System
(
Promega
#
E3310
) following lysis of the nanoparticles with 0.1% Triton-X100.
In vitro
characterization of mRNA translation
(15)
Dilated cardiomyopathy-associated RNA-binding motif protein 20 regulates long pre-mRNAs in neurons
eLife
January 12, 2026
Di Bartolomei G, Ortiz R, Schreiner D, Falkner S, Creemers EEJM, Scheiffele P.
analysis. RNA concentration was determined by
fluorometry
using the
QuantiFluor RNA System
(
Promega
#
E3310
) and 50 ng of RNA was reverse-transcribed for analysis of marker enrichment by
quantitative PCR
(see
(16)
Dilated cardiomyopathy-associated RNA-binding motif protein 20 regulates long pre-mRNAs in neurons
eLife
January 12, 2026
Giulia Di Bartolomei, Raúl Ortiz, Dietmar Schreiner, Susanne Falkner, Esther E J M Creemers, Peter Scheiffele
analysis. RNA concentration was determined by
fluorometry
using the
QuantiFluor RNA System
(
Promega
#
E3310
) and 50 ng of RNA was reverse-transcribed for analysis of marker enrichment by
quantitative PCR
(see
(17)
Paramyxovirus matrix protein redirects METTL3 for dual regulation of viral replication and immune evasion
PLoS pathogens
December 1, 2025
Okura T, Nakai Y, Kameya T, Mizukoshi F, Okura H, Kakizaki M, Kato F, Matsumoto Y, Nakatsu Y, Takeuchi K,
et al
.
IFN-β mRNA. Total RNA was measured by
Quantus Fluorometer
and
QuantiFluor RNA system
(
Promega
, Cat. #
E3310
). RNA quality was then verified using a 5300 Fragment Analyzer System and an Agilent HS RNA Kit (Agilent
(18)
Spliceosome inhibition induces Z-RNA and ZBP1-driven cell death in small cell lung cancer
Cell Reports
October 28, 2025
Xinpei Jiang, Xueying Ma, Yunyun Zhou, Xiaodan Liu, Ting Zhang, William Kim, Siddharth Balachandran, Israel Cañadas
5067–1513
.
5067–1514
,
5067–1535
). RNAs were further quantified using a QuantFluor RNA System (
Promega
;
E3310
) before library preparation. Ribosomal RNA (rRNA) was removed using RiboMinus Core Module V2 (Thermo
(19)
High Prevalence of Potential Molecular Therapeutic Targets in Poorly Differentiated Thyroid Carcinoma
Endocr Pathol
October 22, 2025
Vanessa Zambelli, Giulia Orlando, Marta Fornaro, Giulia Vocino Trucco, Ida Rapa, Francesca Napoli, Susanna Cappia, Lorenzo Daniele, Simonetta Piana, Mauro Papotti,
et al.
Madison, WI, USA, CN:
E4871
) and
Quantifluor RNA System
(
Promega Corporation
, Madison, WI, USA, CN:
E3310
) following the manufacturer’s instructions. DNA quality was evaluated with
real-time PCR
of EGFR Exon2
(20)
Updated efficacy and predictive biomarkers of QL1706, a bifunctional PD-1/CTLA-4 dual blocker in advanced solid tumors—A phase 1/1b study
Cell Reports Medicine
October 21, 2025
Yuxiang Ma, Shaoyan Lin, Qun Chen, Jinhui Xue, Yunpeng Yang, Aimin Zang, Ying Cheng, Yiping Zhang, Xiangcai Wang, Zhendong Chen,
et al.
HS
Assay
Kit,"
Promega
, Madison, WI, USA","
QuantiFluor® dsDNA System
(
E2670
),
QuantiFluor® RNA System
(
E3310
)" DNA/RNA HS Kit,"Agilent Technologies, Santa Clara, CA, USA","
Agilent
High
Sensitivity
DNA Kit (
5067-4626
),
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
QuantiFluor RNA System from Promega
Supplier Page
View Company Product Page
$260.00
Product Specs
Company Info
Citations
Reviews
Back To Top