Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Assay Kits
A Guide to Choosing the Right ELISA Kit
ELISA Plate Readers / Microplate Readers
OmniLog® PM System
Supplier Images
OmniLog® PM System
OmniLog® PM System
OmniLog® PM System from Biolog, Inc.
Be the first to write a review!
Citations:
(15)
Get Pricing
Get Pricing from
Biolog, Inc. for
OmniLog® PM System
Description
Includes the OmniLog® incubator/reader, computer, OmniLog® Phenotpye MicroArray software, electronic user guide, pipettor, turbidimeter and a one year warranty. North American style plug (110-120 VAC)
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
OmniLog® PM System
Company
Biolog, Inc.
Price
Get Pricing
Get Quote for this Product
Catalog Number
93171
Quantity
EA
Applications
Aerobic identification and phenotypic analysis for microbial and mammalian cells; Cell incubation and monitoring
Plate Formats
Biolog MicroPlate™
Add to Compare List
Biolog, Inc.
21124 Cabot Blvd
Hayward
,
California
94545
United States
Phone
: (510) 785-2564
Company Profile
Website:
http://www.biolog.com/
Citations (15)
(1)
Multi-Omic Analysis of Bacteriophage-Insensitive Mutants Reveals a Putative Role for the Rcs Two-Component Phosphorelay System in Phage Resistance Development in Erwinia amylovora
Viruses
November 9, 2025
Nassereldin Ibrahim, Janet T. Lin, Darlene Nesbitt, Joshua Tang, Dharamdeo Singh, Lawrence D. Goodridge, Dion Lepp, Antonet M. Svircev, Joel T. Weadge, Hany Anany
Analyses Phenotypic analysis was carried out using
Biolog
Phenotype MicroArrayTM (PM) plates with an
OmniLog PM system
. Phenotype MicroArrayTM plates include different chemicals that cover carbon-source (PM01-PM02), nitrogen-source
(2)
Analysis of growth dynamics in five different media and metabolic phenotypic characteristics of Piriformospora indica
Frontiers in Microbiology
January 8, 2024
Jing-rong Hu, Jin-meng Li, Hai-yan Wang, Mei-li Sun, Chun-yang Huang, Han-cheng Wang
# 12182, # 12183, #
12161
, and #
12162
), sterile sampling tank (# 3002), FF-IF inoculum (# 72106),
OmniLog PM system
(# 91171), a turbidity meter (# 3531), and an 8-channel electric pipette (# 3501A) were produced by
(3)
Multidrug-resistant E. coli encoding high genetic diversity in carbohydrate metabolism genes displace commensal E. coli from the intestinal tract
PLOS Biology
October 17, 2023
Christopher H. Connor, Amanda Z. Zucoloto, John T. Munnoch, Ian-Ling Yu, Jukka Corander, Paul A. Hoskisson, Braedon McDonald, Alan McNally
12111
), 100 μl of this suspension was added and
strains
incubated for up to 48 h at 37°C, static, in a
OmniLog PM system
(imaging every 15 min). Data was extracted using
Biolog
softwares (conversion of D5E to OKA: D5E_OKA
(4)
Uridine-derived ribose fuels glucose-restricted pancreatic cancer
Nature
June 1, 2023
Nwosu ZC, Ward MH, Sajjakulnukit P, Poudel P, Ragulan C, Kasperek S, Radyk M, Sutton D, Menjivar RE, Andren A,
et al
.
the dye over time was measured as absorbance (A590-A750) using the OmniLog PM-M instrument (
Biolog
,
93171
) for 74.5 h at 15 min intervals. To account for proliferation or
cell number
in the Biolog
screening
(5)
Metabolically versatile psychrotolerant Antarctic bacterium Pseudomonas sp. ANT_H12B is an efficient producer of siderophores and accompanying metabolites (SAM) useful for agricultural purposes
Microbial Cell Factories
April 29, 2023
M. Musialowski, Ł. Kowalewska, R. Stasiuk, T. Krucoń, K. Debiec-Andrzejewska
were performed in triplicates using an OmniLog device (Biolog Inc., USA). All data were collected by
OmniLog PM System
software (
Biolog Inc
., USA). Optimization of medium chemical composition Bacterial inoculum preparation
(6)
Metabolic Characteristics of Porcine LA-MRSA CC398 and CC9 Isolates from Germany and China via Biolog Phenotype MicroArrayTM
Microorganisms
October 26, 2022
Henrike Krüger-Haker, Xing Ji, Alexander Bartel, Andrea T. Feßler, Dennis Hanke, Nansong Jiang, Karsten Tedin, Sven Maurischat, Yang Wang, Congming Wu,
et al.
inoculated with the final cell suspension (100 µL/well) and incubated at 37 °C in the OmniLog incubator. The
OmniLog PM system
(OmniLog
Data Collection
software version 2.3.01) recorded the colorimetric data every 15 min for 48
(7)
Gene-informed decomposition model predicts lower soil carbon loss due to persistent microbial adaptation to warming
Nature Communications
December 1, 2020
Xue Guo et al.
plates with diluted soil supernatant (0.5 g soil with 45 mL 0.85% NaCl) were incubated in a
BIOLOG
OmniLog PM System
at 25 °C for 4.5 days. The color change of each well was shown as absorbance curve. The net area under
(8)
“Mycobacterium mephinesia”, a Mycobacterium terrae complex species of clinical interest isolated in French Polynesia
Scientific Reports
December 1, 2019
Jamal Saad, Michael Phelippeau, May Khoder, Marc Lévy, Didier Musso, Michel Drancourt
a turbidimeter (Biolog Inc). In each case we launched two GENα-MicroPlate and then incubated in the
OmniLog PM System
(
Biolog Inc
.) at 37 °C for 7 days. Lipid extraction and Ion mobility-
mass spectrometry analysis
of
(9)
Mycobacterium ahvazicum sp. nov., the nineteenth species of the Mycobacterium simiae complex
Scientific Reports
December 1, 2018
Amar Bouam et al.
using a turbidimeter (Biolog Inc). Two plates (duplicate) were then inoculated and incubated in the
OmniLog PM System
(
Biolog Inc
.) at 37 °C for three days. The results were obtained as area under the curve (
AUC
) by Biolog’s
(10)
EF-P Posttranslational Modification Has Variable Impact on Polyproline Translation in Bacillus subtilis
mBio
May 2, 2018
Anne Witzky, Katherine R. Hummels, Rodney Tollerson, Andrei Rajkovic, Lisa A. Jones, Daniel B. Kearns, Michael Ibba
inoculating fluid additives where appropriate and aliquoted into wells. The plates were incubated in the
OmniLog PM System
at 37°C for 24 h, with readings taken every hour. Antibiotic
sensitivity
assay
. Overnight saturated
(11)
Modifications of Pseudomonas aeruginosa cell envelope in the cystic fibrosis airway alters interactions with immune cells
Scientific reports
July 6, 2017
Hill PJ, Scordo JM, Arcos J, Kirkby SE, Wewers MD, Wozniak DJ, Torrelles JB.
into the
Biolog
plate wells (catalog #30311). The plate was incubated in the
OmniLog® PM System
(S/N #
93171
) at 37 °C for 24 hours using OmniLog® software analysis (vr. 1.2). The
OmniLog® PM System
generates
(12)
Elucidation of the Metabolic Network of Helicobacter pylori J99 and Malaysian Clinical Strains by Phenotype Microarray
Helicobacter
February 1, 2017
Woon Ching Lee, Khean Lee Goh, Mun Fai Loke, Jamuna Vadivelu
were genomically sequenced and a standard
strain
, H. pylori J99, at the phenotypic level using the
OmniLog PM system
to corroborate genomic data. We used
Biolog
plates PM1 to PM4, giving 190 carbon sources, 95 nitrogen
(13)
High-Throughput Carbon Substrate Profiling of Mycobacterium ulcerans Suggests Potential Environmental Reservoirs
PLOS Neglected Tropical Diseases
January 17, 2017
Dezemon Zingue, Amar Bouam, Muriel Militello, Michel Drancourt
then inoculated in duplicate with 100 μL of inoculating fluid. The PM plates were incubated in the
OmniLog PM System
(
Biolog Inc
.) which
measures
the growth of
mycobacteria
every fifteen minutes for eight days at 30˚C.
(14)
Salmonella Utilizes D-Glucosaminate via a Mannose Family Phosphotransferase System Permease and Associated Enzymes
Journal of Bacteriology
September 15, 2013
Katherine A Miller, Robert S Phillips, Jan Mrazek, Timothy R Hoover
cell suspension, to final concentrations of 20 mM and 2 M, respectively. Plates were incubated in an
OmniLog PM system
at 37°C for 48 h and jb.asm.org 4059 Downloaded from https://journals.asm.org/journal/jb on 16 November
(15)
Assessing the Contributions of the LiaS Histidine Kinase to the Innate Resistance of Listeria monocytogenes to Nisin, Cephalosporins, and Disinfectants
Applied and Environmental Microbiology
April 15, 2012
Barry Collins, Caitriona M. Guinane, Paul D. Cotter, Colin Hill, R. Paul Ross
100 l of inoculated PM9⫹ fluid, and the inoculated plates were monitored hourly for over 24 h in the
Omnilog PM system
(
Biolog, Inc
., Hayward, CA). Kinetic data were analyzed with the Omnilog PM software. A
sensitivity
<<
<
>
>>
Reviews
Be the First to Write a Review!
OmniLog® PM System from Biolog, Inc.
Get Pricing
Get Quote for this Product
Product Specs
Company Info
Citations
Reviews
Back To Top