P/ACE MDQ Plus system from SCIEX

Get Pricing

Get Pricing from
SCIEX for
P/ACE MDQ Plus system

Supplier Page

Description

Fast and practical high resolution separation and quantitation of charged and polar analytes.

The P/ACE series is an automated, programmable capillary electrophoresis system designed to perform fast separations from complex samples. Separations occur in a capillary which is housed in an interchangeable cartridge with circulating liquid coolant for efficient temperature control. This finely regulated temperature control allows the use of high ionic strength buffers and large-bore capillaries necessary for analyzing difficult samples. With CE, methods are faster to develop, easier to validate, and less expensive to run. Note that different detectors are available to optimize performance for your application.

For every researcher there is an ideal analytical technology—one that helps you achieve your goals.


P/ACE MDQ Plus Systems Overview
P/ACE MDQ Plus system with UV detector - B52521 (optional PDA and LIF detectors)

The system includes a selectable-wavelength high sensitivity modular UV/Vis detector (includes 200, 214, 230 and 254 nm filters to optimize analyte specificity), UV source optics, temperature-controlled sample storage module and 32 Karat™ Software configured on a desktop controller. Installation Qualification, Operation Qualification 1 (OQ1) and documentation to aid in software validation is also included.

P/ACE MDQ Plus system with PDA detector - B52521PDA (optional UV and LIF detectors)
Features
  • Built-in auto-sampler and a programmable array of 36 pairs of buffers
  • Exclusive circulating liquid, precisely regulates capillary temperature
  • Sample temperature control
  • Integrated interchangeable detector modules
  • Methods development with 36 position buffer array
  • CAESAR integration algorithms
  • Automatic standards co-injection
  • Multi-mode electrokinetic, pressure and vacuum sample introduction
  • Internal fluidic system with variable pressure or vacuum
  • Robust sample interface
  • Sample from vials, micro vials or 96-well plates
  • Fully programmable separation methods
  • Easy to maintain
Applications
  • Basic drugs
  • Chiral
  • SSCP analysis
  • Quantitation by direct hybridization
A robust sample injection design for demanding analytical requirements
Automated sample handling

The P/ACE MDQ Plus system offers fully automated methods and extended sample-handling capability for walkaway operation.

  • Sampling can be performed using 1.8 ml universal vials, 96-well plates and micro vials.
  • Precision-molded polymethylpentene universal vials accommodate run buffer, sample and micro vials.
Quick-change electrodes

System electrodes and vial cap openers simplify user interaction, are designed to assure high strength and rigidity and are easily removed for maintenance.

Universal vial and cap design

Prevents the capillary and electrode from physically interacting with the caps, creating a better seal, and ultimately allowing for a robust, clean sample interface.

Sample interface

Provides a robust pressure seal ensuring accurate and reproducible data.

Built-in auto-sampler, pressure and vacuum, and sample and temperature control
Capillary temperature control

Efficient CE separations rely on precise capillary temperature regulation to manage Joule heating within the capillary. Proper temperature control plays important role in the repeatability of analysis.

  • Recirculating liquid coolant provides effective heat dissipation when performing assays
  • Capillary temperature can be regulated between 15 - 60°C.
  • Capillaries housed in cartridges facilitate temperature control and easy exchange of capillary dimensions and surfaces
Sample temperature control

Settable temperature between 4 - 60°C helps maintain sample stability or perform functional assays.

Multiple modes of sample introduction and separation

The P/ACE MDQ Plus system provides electrokinetic, pressure and vacuum introduction of samples. Introduction from either end of the capillary allows both ultrafast and high-resolution analyses.

  • Separations can be adjusted by varying voltage, current, pressure and vacuum
  • Combination of voltage and pressure ensures the buffer stays free of air bubbles which can be generated from outgassing
Variable pressure and vacuum

The internal fluidic system operates with all common rinsing protocols, regulating these with a pressure-handling capability of -5 to 100 PSI

  • Capillary conditioning is accomplished by moving specific volumes of electrolytes, gels, regenerants and cleaning solutions through capillary
  • Gel buffers are quickly and efficiently pumped into capillary
Our capillary electrophoresis (CE) technology is used in numerous applications including academic research, industry, small molecule drug development and quality control.
Forensics / Drug screening

While the highly polar nature of basic pharmaceuticals makes Liquid Chromatography complex, CE has the ability to excel at such separations. The robust nature of this tool and the ruggedness of this particular approach are appropriate for screening protocols used in forensic toxicology.

Food and beverage manufacturing

The MDQ Plus system, provides an in-depth analysis of food compounds including anions, cations, organic acid content, and protein integrity, to better manage product process consistency, taste, quality, storage conditions, safety, adulteration and authentication.

Petrochemicals

Analysis of anion and cation content gives you a better understanding of the chemical makeup of petroleum and related products. For example highly purified terephthalic acid (PTA) and its esters are major components in the production of plastics and fibers like polyethylene glycol and polyester. The purity of PTA has a direct effect on the quality and color of the end products.

Biofuels

The P/ACE MDQ system plus already excels in ion analysis and is a natural fit for biofuel production. The fermentation of lignocellulosic biomass to ethanol[1] is an attractive route to fuels that supplements fossil fuels. Incorporating, ion analysis, protein purity assays, isoelectric focusing and sugar analysis by capillary electrophoresis is invaluable in monitoring the fermentation and purification processes used in ethanol production.

Water quality and environmental

With ever-increasing water demands, quick and efficient identification of impurities, analytes, or other contaminating molecules within a water sample is a key step in managing the safety of our water supply. Water is also a vital component in the industrial production of semiconductors, metal plating, and is used in large volumes in nuclear power plants and pulp and per mills. The P/ACE MDQ Plus system identifies analytes that lead to corrosion as well as contaminants that contribute to downstream environmental pollution.



Supplies and accessories
  • Universal vial caps (100 pack): P/N A62250
  • Universal vials (100 pack): P/N A62251
  • 200 μL microvials (100 pack): P/N 144709
  • NanoVials (100 pack): P/N 5043467
  • Electrode assembly: P/N A47775
  • Vial cap opener: P/N A95348
  • Vial holder assembly, 6x6 (36 vials): P/N A94462
  • Vial holder assembly, 6x8 (48 vials): P/N A94461
  • Capillary cartridge, semi assembled (no capillary): P/N A11147
  • Blank cartridge assembly kit: P/N 144738
  • Cartridge rebuilding kit: P/N 144645
  • Cartridge tubing: P/N 144689
  • Capillary cartridge coolant (450 mL): P/N 359976