Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
SA3800 Spectral Analyzer
Supplier Images
Published Figures
SA3800 Spectral Analyzer
SA3800 Spectral Analyzer from Sony Corporation
Be the first to write a review!
Citations:
(357)
Figures:
(9)
Inquire
from
Sony Corporation for
SA3800 Spectral Analyzer
Description
SA3800 spectral analyzer / flow cytometer features ease-of-use, automation and spectral technology to optimize sensitivity and simplify workflow.
Product Specs
Citations
Reviews
Product Specs
Item
SA3800 Spectral Analyzer
Company
Sony Corporation
Price
Inquire
Catalog Number
SA3800
Lasers
1 to 4 lasers
Excitation
405 nm, 488 nm, 561 nm, 638 nm
Parameters
32 fluorescence channels
Capacity
Tubes (5 mL), Microplates (96-well, 384-well)
Data Throughput
20,000 events/sec (max)
Dimensions
(WxDxH) 66 x 63.5 x 67.4 cm
Flow Rate
(33 µL/min) normal, or high (250 µL/min)
Add to Compare List
Citations (357)
(1)
Discovery of a secreted Bacteroides fragilis mucinase that cleaves mucins with bis-T O-glycans through a carbohydrate binding module-dependent mechanism
Gut Microbes
December 31, 2026
Yoshiki Narimatsu, Cayetano Pleguezuelos-Manzano, Daniel Hornikx, Felix Goerdeler, Thapakorn Jaroentomeechai, Katia Flores, Sanae Narimatsu, Charelle Boot, Lars Hansen, Fabien Durbesson,
et al.
(
clone
L5, BioLegend) for 30 min at 4 °C. After another wash with PBA, cells were analyzed using a
Sony
SA3800 spectral analyzer
. For cells transiently expressing reporters, binding of the anti-FLAG antibody was measured both GFP
(2)
Host-directed clearance of nuclear tegument U14 terminates NF-κB signaling and supports HHV-6A replication
PLoS Pathog
September 23, 2026
Khoir Amaliin, Mansaku Hirai, Salma Aktar, Tetsuo Koshizuka, Yasuko Mori, Jun Arii
(Nacalai Tesque) in Annexin V-633 binding buffer. Samples were analyzed by
flow cytometry
on a
Sony
SA3800
instrument. Early apoptotic (Annexin V ⁺ /PI-) and late apoptotic (Annexin V ⁺ /PI⁺) populations were
(3)
Reprogramming M2 macrophages via TLR7/8 agonist-loaded hollow MnO2 nanovehicles to suppress the progression of liver cancer
PLoS One
September 18, 2026
Pei-Pei He, Zheng-Ju Hou, Han-Mei Li, Ji-Xuan Zhang, An-Qi Chen, Quan-You Miao, Chao-Feng Yang, Jin-Hong Yu, Yang Li
resuspended in 500 µL fixative solution, and analyzed for
fluorescence
intensity using a
flow cytometer
(
SA3800
,
Sony Corporation
, Tokyo, Japan). 2.11.
In Vitro
immune response activation RAW 264.7
macrophages
(4)
Ca16Mab-56, a Novel Anti-Cadherin-16/Ksp-Cadherin Monoclonal Antibody for Multiple Applications
Antibodies (Basel)
September 7, 2026
Yukari Ogura, Hiroyuki Suzuki, Mika K. Kaneko, Yukinari Kato
(
1:2000
; Cell Signaling Technology, Inc., Danvers, MA, USA).
Flow cytometric
data were acquired on an
SA3800
Cell Analyzer (
Sony
Corp., Tokyo, Japan). Cells were gated on forward scatter (FSC) and side scatter
(5)
A Versatile Anti-CXCR5 Monoclonal Antibody (Cx5Mab-6) for Basic Research and Diagnosis
Curr Issues Mol Biol
September 3, 2026
Airi Nomura, Hiroyuki Suzuki, Saori Okuno, Haruto Yamamoto, Reina Ito, Yukari Ogura, Kai Shimizu, Takuro Nakamura, Miyuki Yanaka, Saori Handa,
et al.
RdMab-20, respectively) were described previously [29,30].
Flow cytometric
data were acquired on an
SA3800
Cell Analyzer (
Sony
Corp., Tokyo, Japan). Cells were gated on forward scatter (FSC) and side scatter
(6)
Potential Shared Immunometabolic Signatures Between Familial Hypercholesterolemia and Major Depressive Disorder: Integrative Transcriptomic Analysis, Mendelian Randomization, and Clinical Validation
International Journal of Molecular Sciences
August 22, 2026
Chenxi Liu, Yuting Li, Xiang Cao, Zixuan Ye, Quanzhou Shi, Feng Chen, Zihao Li, Jiamei Guo, Tian Qiu
quantified as the proportion of HLA-DR+ cells among total CD3+CD4+ T cells. Data were acquired using a
Sony
SA3800
Spectral Cell Analyzer and analyzed using a standardized gating strategy. Detailed antibody information
(7)
Altered MicroRNA Signatures in Circulating Extracellular Vesicles Reflect Aortic Dilation in Takayasu Arteritis
J Extracell Biol
August 17, 2026
Kohei Kawajiri, Shun Nakagama, Tetsuo Sasano, Yasuhiro Maejima
Characterization Serum‐derived EVs were characterized by high‐
sensitivity
flow cytometry
using the
SA3800
system (
Sony
, Japan). EV samples were diluted in 0.22 µm‐filtered, calcium‐ and magnesium‐free PBS and
(8)
Specific targeting of cancer cell mitochondria with a malaria drug improves pancreatic cancer outcome
Scientific Reports
August 16, 2026
Yan Ou, Adrian Lim, Ruoxiang Wang, Nora Mir, Vinicius F. Calsavara, Qiang Wang, Yi Zhang, Stephen J. Pandol, Mouad Edderkaoui
MitoSOX at 37 °C in the incubator for 30 min and
staining
was analyzed by
flow cytometry
using
Sony
SA3800
. Animals All animal studies were performed according to the guidance of IACUC and after the approval
(9)
Tyro3 facilitates cytoplasmic delivery of extracellular vesicle contents and antigen presentation via major histocompatibility complex class I in dendritic cells
PLoS One
August 4, 2026
Takashi Koyama, Katsuhiko Kojima, Koki Maeda, Takahide Matsui, Hitomi Kosai, Noriko Ishida, Eiji Morita, Mitsunori Fukuda, Nobuyuki Tanaka
permeabilization buffer. See antibodies used
for flow cytometry
in S2 Table. We used a
SONY
Cell Analyzer
SA3800
and analyzed the data using FlowJo software (version 10.10.0; BD Biosciences). sEV binding and internalization
(10)
Structural and functional characterization of a conserved cryptic epitope on SARS-CoV-2 spike S2 subunit
PLoS Pathog
August 3, 2026
Ling Zhou, Ching-Lin Hsieh, Sarah R. Leist, Emily Happy Miller, Andrew P. Horton, Sophie R. Shoemaker, Elizabeth C. Gardner, John M. Powers, Daniel R. Boutz, Michael L. Mallory,
et al.
resuspended in 200 μL of ice-cold PBSA immediately prior to analysis. Samples were analyzed using a
Sony
SA3800
Spectral Cell Analyzer. Long-read sequencing
Sequencing
libraries were prepared from amplicon samples
(11)
In silico high-throughput screening system for INMT activators in prostate cancer therapy
Front Pharmacol
July 23, 2026
Haoyuan Zheng, Shilong Cao, Zhuoling Kong, Peng Xin, Jianbin Bi, Jianfeng Wang
light exclusion, rinsed with serum-free medium, and the resulting
fluorescence
was recorded on a
Sony
SA3800 spectral analyzer
(λex 488 nm, λem 525 nm).
Mitochondrial membrane
potential (MMP) assessment MMP was monitored with
(12)
TGFB2-mediated regeneration of pelvic ligament equivalents using a stem cell-fibroblast-decellularized membrane composite
Front Bioeng Biotechnol
July 23, 2026
Yingying Dong, Yu Zhang, Yinan Duan, Zhijun Xia
CD90 (
BD Biosciences
,
555595
) according to manufacturer’s instructions. Data were acquired on a
SONY
SA3800
flow cytometer
and analyzed using FlowJo software (v10.8.1). 2.2 HVFs extraction and identification Vaginal
(13)
Combination of proton-pump inhibitor and anti-CD3 F(ab')2 for islet neogenesis and immune modulation in type 1 diabetes
Immunother Adv
July 22, 2026
Tung-Yun Wu, Che-Yi Chen, Michael Chen, Chang-Hung Wang, An-Pei Kao, Kai-Hung Wang, Kuo-Hsiang Chuang, Shyr-Yi Lin
Factor Staining Buffer Set according to the manufacturer's protocol. Samples were analyzed on a
Sony
SA3800
flow cytometer
.
Immunohistochemistry
for β-cell function and neogenesis Paraffin-embedded pancreas
(14)
Lactobacillus helveticus GCL1815 induces Th1-skewing T-cell responses via dendritic cell activation
Biochem Biophys Rep
July 13, 2026
Yuma Matsumoto, Keisuke Yamane, Keigo Tsuruno, Taisuke Uesugi, Soichi Tanabe, Yasuo Saito
Thermo Fisher Scientific), and
CD8
(PE-Cy7,
clone
SK1; BioLegend). Samples were acquired on a
Sony
SA3800
flow cytometer
and analyzed using FlowJo software version 10.8.1 (Becton, Dickinson and Company, Ashland,
(15)
A Novel Anti-Cadherin-17 Monoclonal Antibody, Ca17Mab-5, for Multiple Applications
Antibodies (Basel)
July 10, 2026
Reina Ito, Hiroyuki Suzuki, Kenichiro Ishikawa, Kazutake Yagi, Akira Ohkoshi, Yukio Katori, Mika K. Kaneko, Yukinari Kato
(
1:2000
; Cell Signaling Technology, Inc., Danvers, MA, USA).
Flow cytometric
data were acquired on an
SA3800
Cell Analyzer (
Sony
Corp., Tokyo, Japan). Cells were gated on forward scatter (FSC) and side scatter
(16)
Harnessing the PpHog1 Regulatory Network to Engineer a UPR-Adaptive Komagataella phaffii Chassis for High-Copy Secretory Protein Production
Microb Biotechnol
July 9, 2026
Jiacheng Shi, Zhanqing Lv, Chaoyu Lu, Bohao Fang, Zerui Zou, Mian Zhou
OD600 = 1. A 500 μL aliquot of the cell suspension was subjected to sorting by
flow cytometry
(
SONY
SA3800
), with an excitation wavelength of 561 nm and detection via the FL2 channel. 2.10 Fermentation in 1‐L
(17)
The role and mechanism of tubulin folding cofactor B in glioblastoma migration
Cell Death Discovery
June 30, 2026
Bingqiu Zhang, Qiang Wang, Chenglong Ouyang, Mei Yang, Qiuxi Chen, Xiaoqiao Chen, Fei Gao, Hui Liu
at 2–8 °C for 30 min before
flow-cytometric analysis
.
Fluorescence
signals were acquired on a
Sony
SA3800
flow cytometer
using 488 nm excitation. For each sample, 2 × 10^4 events were collected. The raw data
(18)
Lilrb4a Suppression Reprograms Microglia to Mitigate APOE4‐Associated Amyloid Plaques and Cerebral Amyloid Angiopathy in Association With a PPAR‐Linked Pro‐Clearance State
Advanced Science
June 22, 2026
Changxu Nie, Ruixi Yang, Xiaotong Wang, Ping Jia, Xueqi Zhang, Yaqi Dai, Xue Bai, Sijia Duan, Yufeng Li, Peng Zheng,
et al.
Incucyte S3
system (
Sartorius
) or 200 nm FAM‐labeled Aβ oligomers for
flow cytometric analysis
using a
SONY
SA3800
cell analyzer. Phagocytosis was assessed after 1.5 h of substrate internalization. For degradation
assays
,
(19)
Respiratory syncytial viral load drives ciliated cell dedifferentiation and suppresses antiviral immunity
Sci Adv
June 19, 2026
Kevin Berg, Sibylle Haid, Ehsan Vafadarnejad, Arnaud Carpentier, Robert Geffers, Bettina Wiegmann, Antoine-Emmanuel Saliba, Florian Erhard, Thomas Pietschmann
least 30 min. Cells were stored at 4°C upon
flow cytometric analysis
using a
SONY
spectral analyzer
SA3800
, and results were analyzed using FlowJo V10. Gating strategy is depicted in fig. S1C.
Flow cytometry analysis
(20)
Surfaceome Reprogramming of Stemsomes Promotes Lung Cancer Targeting via Potentiated Receptor–Ligand Interactions
Advanced Science
June 9, 2026
Geunhye Kim, In Ah Kwon, Bo Seop Jeong, Hyo Seon Kim, Joo‐Hwan Park, Sung Jean Park, Sang‐Rae Lee, Youngki Lee, Dongwoo Khang
for 30 min at 4°C and centrifuged again.
Fluorescence
was measured using a spectral cell analyzer (
SA3800
,
Sony
), and data were analyzed using FlowJo software (FlowJo, Ashland, OR, USA). 5.26
mRNA‐Seq
Total
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
SA3800 Spectral Analyzer from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top