Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
Spatial Biology
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Equipment
Bio-Dot SF Apparatus
Supplier Images
Bio-Dot SF Apparatus
Bio-Dot SF Apparatus
Bio-Dot SF Apparatus
Bio-Dot SF Apparatus from Bio-Rad
Be the first to write a review!
Citations:
(26)
Get Pricing
Get Pricing from
Bio-Rad for
Bio-Dot SF Apparatus
Supplier Page
Description
Slot blotting microfiltration device, includes 48-well slot-format sample template, vacuum manifold base, gasket support plate, gasket, filter paper
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
Bio-Dot SF Apparatus
Company
Bio-Rad
Price
$944.00
Get Pricing
Catalog Number
1706542
Quantity
1EA
Add to Compare List
Bio-Rad
Bio-Rad Laboratories, Inc. Life Science Research Group 2000 Alfred Nobel Drive
Hercules
,
California
94547
United States
Phone
: 800-424 6723
800-879 2289
Company Profile
Website:
http://discover.bio-rad.com
Citations (26)
(1)
Pervasive suppressors halt the spread of selfish Segregation Distorter in a natural population
GENETICS
August 5, 2026
Ching-Ho Chang, Tyler Handler, Nicholas J Fuda, Danielle Pascua, Taylar Mouton, Amanda M Larracuente
0.45 μm Nylon
membrane
[
Thermo Scientific
77016
] in triplicate using Bio-Dot SF slot blotter [
Bio-Rad
#
1706542
], and each slot was rinsed with 150 μL loading buffer and 200 μL 400 mM
Tris
-Cl (pH 7.5). After rinsing
(2)
Chronic Sleep Disturbance Enhances Inflammation and Collagen Production in Neural- and Myofascial Tissues in Uninjured Rats
Int J Mol Sci
July 8, 2026
Mikhail A. Kolpakov, Betsy A. Kalicharan, Lewis Bright-Rowe, Frank L. Chen, Khyleisha A. Caesar, Yasmine B. Dahleh, Abby Kegg, Brendan A. Hilliard, Soul M. Moreno, Megan Van Der Bas,
et al.
slot blot
or
Western blot
methods. A
slot blot
microfiltration device was used (
Bio-Dot® SF Apparatus
,
1706542
,
Biorad
, Hercules, CA, USA), per manufacturer’s directions and described methods [103]. After transfer,
(3)
Recurrent patterns of TOP1-mediated neuronal genomic damage shared by major neurodegenerative disorders
Cell
July 1, 2026
Zinan Zinan Zhou, Lovelace J. Luquette, Guanlan Dong, Junho Kim, Jayoung Ku, Kisong Kim, Nandini Ramesh, Mingyun Bae, Ann Caplin, Diane D. Shao,
et al.
nitrocellulose
membrane
(
Bio-Rad
1620115
) using the Bio-Dot® SF Microfiltration Apparatus (
Bio-Rad
1706542
) according to the manufacturer’s instructions.
Membranes
were UV-crosslinked for 10 min and blocked
(4)
Therapeutic nanoliposome vaccine targeting multiple Aβ and tau epitopes reduces AD-like brain pathologies and rescues cognitive deficits in 3xTg-AD mice
Brain, Behavior, & Immunity - Health
February 1, 2026
Chun-Ling Dai, Yiting Song, Yonghua Chen, Yunn Chyn Tung, Wei-Chiao Huang, Cheng-Xin Gong, Jonathan F. Lovell
integrity of SNAP-AD5 in particle form with liposome, we set up a 48-well slot apparatus (
Bio-Rad
, catalog#
1706542
) with the provided instruction. Initially, 50 μL of PBS was applied to each well to check for leakage.
(5)
Pre- and postsynaptic upregulation of FasII synergistically underlies neuropathological and behavioral phenotypes in a Drosophila model of myotonic dystrophy
Nature Communications
December 18, 2025
Alex Chun Koon, Ka Yee Winnie Yeung, Yitao Wu, Lok I Leong, John Tsun Po Cheung, Zhefan Stephen Chen, Shaohong Isaac Peng, Noah S. Armstrong, C. Andrew Frank, Paul Magneron,
et al.
and equilibrated in 1× PBS (Gibco, 20012-019) and then placed in the
Bio-Dot® SF Apparatus
(
Bio-Rad
,
1706542
).
Membrane
slots were rinsed with 100 µL 1× PBS, and then loaded with 20 µg frontal cortex protein in
(6)
Differential effects of mercury compounds on mutagenicity, genotoxicity and repair of UV-DNA damage
Toxicology
December 1, 2025
Anna Cyran, Giorgiana Madalina Ursu, Casey Krawic, Anatoly Zhitkovich
DNA (300 ng) was deposited on 0.22 μm nitrocellulose
membrane
(
1620112
) using
Bio-Dot SF apparatus
(
1706542
) from
Bio-Rad
(Hercules, CA, USA). CPDs (CAC-NM-DND-001) and 6–4PPs (CAC-NM-DND-002) were detected with
(7)
Creatine Kinase Blockade Disrupts Energy Metabolism and Redox Homeostasis to Suppress Osteosarcoma Progression
International journal of molecular sciences
November 28, 2025
Kishi S, Sasaki R, Fujiwara-Tani R, Ohmori H, Luo Y, Fujii K, Sasaki T, Goto K, Miyagawa Y, Kawahara I,
et al
.
lysates (1 μg/10 µL TBSB) were applied to nitrocellulose using a Bio-Dot SF Microfiltration Apparatus (#
1706542
,
Bio-Rad
, Tokyo, Japan), dried, and processed similarly to
Western blots
. 4.13.
Knockdown
Assay
CKB
(8)
Pervasive suppressors halt the spread of selfish Segregation Distorter in a natural population
bioRxiv
October 17, 2025
Ching-Ho Chang, Tyler Handler, Nick Fuda, Danielle Pascua, Taylar Mouton, Amanda M Larracuente
0.45um Nylon
membrane
[
Thermo Scientific
77016
] in triplicate using Bio-Dot SF slot blotter [
Bio-Rad
#
1706542
], and each slot was rinsed with 150ul loading buffer and 200ul 400mM
Tris
-Cl (pH 7.5). After rinsing
(9)
Oxidative damage within alternative DNA structures results in aberrant mutagenic processing
Nucleic Acids Res
February 14, 2025
Maha Zewail-Foote, Imee M A Del Mundo, Alex W Klattenhoff, Karen M Vasquez
-
slot blot
assay
was carried out according to the protocol recommended by the supplier (
Bio-Rad
, Catalog #
1706542
). After transferring the purified DNA fragments, the nitrocellulose
membrane
was baked for 2 h at 80°C
(10)
Dual inhibition of aminoacyl-tRNA synthetase interacting multifunctional protein-2 and α-synuclein by steroid derivative is neuroprotective in Parkinson''s model
iScience
November 15, 2024
Shin JY, Ha MW, Kim JH, Cheon J, Lee GH, Paek SM, Lee Y.
sheets of 3M paper and one sheet of
membrane
are placed on the
dot blot
machine (BIO-Dot
BIO-RAD
, cat#
1706542
), and the screws were tightened. Samples, 100 μl each, were loaded through vacuum into each well. The
(11)
Mouse α-synuclein fibrils are structurally and functionally distinct from human fibrils associated with Lewy body diseases
Science advances
November 1, 2024
Sokratian A, Zhou Y, Tatli M, Burbidge KJ, Xu E, Viverette E, Donzelli S, Duda AM, Yuan Y, Li H,
et al
.
tris-buffered saline (TBS), using a bio-dot slot format microfiltration apparatus (
Bio-Rad
, catalog #
1706542
). Samples were filtered and washed in tris-buffered saline with 0.1% tween-20 detergent (TBST) through
(12)
Adjuvanted nanoliposomes displaying six hemagglutinins and neuraminidases as an influenza virus vaccine
Cell Reports Medicine
March 19, 2024
Zachary R. Sia, Jayishnu Roy, Wei-Chiao Huang, Yiting Song, Shiqi Zhou, Yuan Luo, Qinzhe Li, Dominic Arpin, Hilliard L. Kutscher, Joaquin Ortega,
et al.
PA",
MB-201-0200
Nitrocellulose Membrane,
Thermo Fisher Scientific
,
77012
48-Well
Slot Blot
Apparatus,
Bio-Rad
,
1706542
"Cell Strainer, 70 μm mesh","VWR, North American",76327–100
(13)
Upregulation of LRRK2 following traumatic brain injury does not directly phosphorylate Thr175 tau
Frontiers in Cellular Neuroscience
November 8, 2023
Neil Donison, Matthew Hintermayer, Maegha Subramaniam, Erin Santandrea, Kathryn Volkening, Michael J. Strong
nitrocellulose
membrane
was pre-soaked in TBS and placed in the Bio-Dot SF Microfiltration Apparatus (
Bio-Rad
#
1706542
). The
membrane
was rehydrated by adding TBS to each well, followed by adding equal amounts of protein
(14)
Preparation of chaperone-loaded neural stem cell-derived extracellular vesicles to reduce protein aggregation in Huntington’s disease cellular models
STAR Protocols
March 1, 2023
Bhagyashree S. Joshi, Inge S. Zuhorn
-80°C for later use.100.Setting up of FTA
Bio-Dot apparatus
–a.Open the
Bio-Dot SF apparatus
(
Biorad
,
1706542
). Make sure it is thoroughly cleaned with water and soap.b.Prepare FTA wash buffer (10 mM
Tris
-Cl pH
(15)
Targeting G-quadruplex for rescuing impaired chondrogenesis in WRN-deficient stem cells
Cell & bioscience
December 31, 2022
Leung AO, Yiu TC, Liu L, Tam HY, Gu S, Tu J, Pei D, Cheung HH.
um, Thermo) and filter papers were pre-wet for 10 min in TBS. After assembly of
Slot blot
apparatus (
1706542
,
Bio-Rad
), 200 µL TBS were applied to each well and vacuumed through. 200 µL of samples or TBS were
(16)
NEDDylated Cullin 3 mediates the adaptive response to topoisomerase 1 inhibitors
Science advances
December 9, 2022
Meroni A, Grosser J, Agashe S, Ramakrishnan N, Jackson J, Verma P, Baranello L, Vindigni A.
was then deposited onto a 0.45-μm nitrocellulose
membrane
(Amersham) using a slot
blotting
apparatus (
1706542
,
Bio-Rad
). TOP1-ccs were detected by overnight
incubation
with primary rabbit anti-TOP1 antibody (
1:2000
;
(17)
Loss of heat shock factor initiates intracellular lipid surveillance by actin destabilization
Cell Reports
October 18, 2022
Abigail Watterson, Sonja L.B. Arneaud, Naureen Wajahat, Jordan M. Wall, Lexus Tatge, Shaghayegh T. Beheshti, Melina Mihelakis, Nicholas Y. Cheatwood, Jacob McClendon, Atossa Ghorashi,
et al.
added to samples for a final concentration of 0.5% SDS. The Bio-Dot SF
slot blot
apparatus (
Bio-Rad
1706542
) was assembled with a 0.45-μm pore size cellulose acetate
membrane
(Sterlitech CA0453001) atop pre-soaked
(18)
Filter trapping protocol to detect aggregated proteins in human cell lines
STAR protocols
September 16, 2022
Chhipi-Shrestha JK, Yoshida M, Iwasaki S.
Paper,
Bio-Rad
,Cat#
1620161
0.2-μm cellulose acetate
membrane
filter,Cytiva,Cat#10404180
Bio-Dot SF Apparatus
,
Bio-Rad
,Cat#
1706542
Square petri dish,Greiner Bio-One,Cat#07-000-330 Seesaw shaker,Biocraft,BC-700
Odyssey CLx Infrared Imaging System
(19)
XPC-PARP complexes engage the chromatin remodeler ALC1 to catalyze global genome DNA damage repair
Nature communications
August 13, 2022
Blessing C, Apelt K, van den Heuvel D, Gonzalez-Leal C, Rother MB, van der Woude M, González-Prieto R, Yifrach A, Parnas A, Shah RG,
et al
.
vacuum-transferred to a nitrocellulose
membrane
using the Bio-Dot or
Bio-Dot-SF apparatus
(
Bio-Rad
,
1706542
/5).
Membranes
were baked at 80 oC in a Bio-Rad’s Gel Dryer model 583, blocked in 5% milk in PBS with
(20)
A rapid method to visualize human mitochondrial DNA replication through rotary shadowing and transmission electron microscopy
Nucleic Acids Research
December 2, 2021
Martin Kosar, Daniele Piccini, Marco Foiani, Michele Giannattasio
#GERPN203B), previously equilibrated with TE, using a Bio-Dot SF microfiltration apparatus (
Bio-Rad
, #
1706542
) following manufacturer instructions. The Hybond N +
membrane
was washed with 200 μl of TE and exposed
Page
<<
<
1
2
>
>>
Reviews
Be the First to Write a Review!
Bio-Dot SF Apparatus from Bio-Rad
Get Pricing
$944.00
Product Specs
Company Info
Citations
Reviews
Back To Top