Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Chromatography Equipment
Chromatography and Separation
Micro Bio-Spin™ Chromatography Columns
Supplier Images
Micro Bio-Spin™ Chromatography Columns
Micro Bio-Spin™ Chromatography Columns from Bio-Rad
Be the first to write a review!
Citations:
(207)
Supplier Page
Supplier Page from
Bio-Rad for
Micro Bio-Spin™ Chromatography Columns
Description
Pkg of 100, empty polypropylene spin columns, 0.8 ml bed volume, disposable, autoclavable
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
Micro Bio-Spin™ Chromatography Columns
Company
Bio-Rad
Price
$165.00
Supplier Page
View Company Product Page
Catalog Number
7326204
Quantity
Pkg of 100
Type
Columns
Add to Compare List
Bio-Rad
Bio-Rad Laboratories, Inc. Life Science Research Group 2000 Alfred Nobel Drive
Hercules
,
California
94547
United States
Phone
: 800-424 6723
800-879 2289
Company Profile
Website:
http://discover.bio-rad.com
Citations (207)
(1)
Protocol to identify covalent inhibitors targeting RhoA Cys16
STAR Protoc
April 14, 2026
Tin-Yan Koo, Chloe See-Hang Ho, Hillary Yui-Yan Yip, Clive Yik-Sham Chung
V5111
C18 Stage Tips,
Thermo Scientific
™,Cat#
87782
Micro Bio-Spin Chromatography Columns
,
Bio-Rad
,Cat#
7326204
Aurora C18
UHPLC
column (75 μm i.d. × 25 cm length × 1.6 μm particle size),IonOpticks Australia,https://ionopticks.com/product/aurora-ultimate-25cm-x-75um-c18-
uhplc
-column/
(2)
A bacterial family of fatty acid acyltransferases related to the Shigella effector IcsB
mBio
April 8, 2026
Waad Bajunaid, Kyle Tomaro, Anwer Hasil Kottarampatel, Geneviève F. Desrochers, Mathieu Lavallée-Adam, John P. Pezacki, François-Xavier Campbell-Valois
bead slurry (
Thermo Scientific
,
20353
) was washed 3× with 700 μL PBS in a biospin column (
Bio-Rad
,
7326204
) at 1,000 × g for 1 min. Beads were then transferred to protein samples using 500 μL PBS and rotated
(3)
Chiral methionine oxidation reagents reveal stereospecific proteome modifications
bioRxiv
March 30, 2026
Angel Gonzalez-Valero, Annika C. S. Page, Jayde M. Bertoch, Fadi Alsarhan, Jaehee Kim, Amr A. Alazali, Ritwik R. Srinivas, Xiao Xie, Audrey G. Reeves, Kacper Skakuj,
et al.
beads were then washed with 500 μL PBS (5X) and 500 μL MQ (5X) in micro bio-spin columns (
Bio-Rad
;
7326204
) on a vacuum manifold. With the final wash, samples were transferred to a fresh 1.7 mL microcentrifuge
(4)
Development of DNA Aptamers Against Leishmania infantum GP63 Protein for Therapeutic and Diagnostic Applications
Pharmaceutics
February 28, 2026
Lucía Román-Álamo, Daniela Currea-Ayala, Gabriel S. Oliveira, Antonino Nicolò Fallica, Timen Mooren, Yunuen Avalos-Padilla, Xavier Fernàndez-Busquets
quantified in a Nanodrop 2000 (Thermo Fisher Scientific), and the forward single strand was purified in
Micro Bio-Spin chromatography columns
(
Bio-Rad Laboratories
, Inc.) loaded with High Capacity NeutrAvidinTM Agarose (Thermo Fisher Scientific),
(5)
Defining RNA oligonucleotides that reverse deleterious phase transitions of RNA-binding proteins with prion-like domains
Molecular Cell
January 8, 2026
Lin Guo, Jacob R. Mann, Jocelyn C. Mauna, Katie E. Copley, Hejia Wang, Jack D. Rubien, Cristian A. Bergmann, Jenny L. Carey, Jessica Merjane, Marilyn Ngo,
et al.
TDP-43-MBP-his was buffer exchanged into 166.66mM NaCl, 22.22mM HEPES-NaOH pH 7.0, 1.11mM DTT (
Bio-Rad
Micro Bio-Spin Chromatography Columns
, following manufacturer’s instructions) and concentration was determined via NanoDrop, e280=114250 cm−1M−1.
(6)
Anionic Detergents as Eluents for Microscale Isolation of Antigen-Specific Serum Immunoglobulins
Biosensors (Basel)
December 28, 2025
Dmitry Trukhin, Marina Filippova, Alla Tskaeva, Ekaterina Troshina, Dmitry Gryadunov, Elena Savvateeva
Immunoglobulins 2.5.1.
Gel Filtration
The obtained eluates (100 µL) were applied to spin columns (
7326204
,
Bio-Rad Laboratories
, USA) filled with
Sephadex G-25 coarse
(
17-0034-02
,
GE Healthcare
, Chicago, IL,
(7)
A non-enzymatic role of Nudix hydrolase 5 in repressing purine de novo synthesis
Science
December 11, 2025
Tuan-Anh Nguyen, Jung-Ming G. Lin, Anne-Sophie M. C. Marques, Maximilian Fottner, Ludwig G. Bauer, Andreas Reicher, Diana Daum, Lorenzo Scrofani, Yusi Liu, Carol Cheng,
et al.
After 1 h
incubation
at 4°C while being rotated, beads were transferred to a Mini Spin column (
BioRad
,
7326204
) and washed twice with wash buffer (lysis buffer without protease
inhibitor
) and once with Tris-HCl
(8)
Single-cell mapping of the glycocalyx in the adult human and mouse ocular surface
PNAS Nexus
October 31, 2025
Rafael Martínez-Carrasco, Pablo Argüeso
(
Thermo Fisher Scientific
) according to the manufacturer's instructions. The beads were loaded into
Micro Bio-Spin chromatography columns
(
Bio-Rad
, Hercules, CA, USA). Conjugated lectins were dissolved in up to 200 µL of Dulbecco's phosphate-buffered
(9)
Phosphate ions modulate enzyme activity and epistatic effects in two clavulanic acid-resistant β-lactamase mutants
Protein Sci
October 11, 2025
Marko Radojković, Saar F. Koene, Aleksandra Chikunova, Bogdan I. Florea, Sivanandam V. Natarajan, Aimee L. Boyle, Marcellus Ubbink
enzyme‐to‐
inhibitor
ratio). After thawing, the sample buffer was exchanged for 10 mM ammonium acetate, pH 6.8, using
Micro Bio‐Spin chromatography columns
(
Bio‐Rad
). Samples were then loaded onto a Silica‐C4 reversed phase UPLC column and analyzed using a
(10)
Mannose trimming is the dominant signal for the release of misfolded glycoproteins from ER quality control
Journal of Biological Chemistry
October 1, 2025
Yun-Ji Shin, Ulrike Vavra, Daniel Maresch, Clemens Grünwald-Gruber, Richard Strasser
CA-630, followed by one washing step using the same buffer solution. The beads were then transferred to
Micro Bio-Spin chromatography columns
(
Bio-Rad
) and washed twice with 600 μl of a buffer solution containing 10 mM Tris–HCl, pH 7.5, 150 mM
(11)
Molecular determinants for the endocytosis of the voltage-gated K + channel Kv1.3
Science Signaling
September 30, 2025
Irene Estadella, María Navarro-Pérez, Magalí Colomer-Molera, Michael L. Dustin, Alexander Sorkin, Jesusa Capera, Antonio Felipe
mixing. The beads were removed by
centrifugation
at 1000g for 30 s. Samples were incubated overnight in
Micro Bio-Spin Chromatography Columns
(
Bio-Rad
) with 50 μl of protein A-Sepharose beads and anti–green fluorescent protein (GFP) (4 ng of
(12)
Classically activated macrophages undergo functionally significant nucleotide metabolism remodelling driven by nitric oxide
Nature Metabolism
August 4, 2025
Steven V. John, Gretchen L. Seim, Billy J. Erazo-Flores, James A. Votava, Uzziah S. Urquiza, Nicholas L. Arp, John Steill, Jack Freeman, Lauren N. Carnevale, Isaiah Roberts,
et al.
25°C. The total volume was spun at 1,000 × g for 4 minutes at 4°C in a
chromatography
column (
BioRad
:
7326204
). The flowthrough was transferred to a 30 kDa MWCO filter (
Sigma Aldrich
:
UFC503024
). 300 μL of storage
(13)
Structures of Mycobacterium tuberculosis isoprenyl diphosphate synthase Rv2173 in substrate-bound forms
Acta Crystallographica Section F Structural Biology Communications
May 1, 2025
James A. Titterington, Ngoc Anh Thu Ho, Charles P. H. Beasley, Francis Mann, Edward N. Baker, Timothy M. Allison, Jodie M. Johnston
analysis, the protein sample (0.2 mg ml−1) was buffer-exchanged into 0.75 M ammonium acetate using
Micro Bio-Spin Chromatography Columns
(
Bio-Rad
) and then centrifuged at 17 000g for 2 min before dispensing into an electrospray capillary.
(14)
Antibiotic target discovery by integrated phenotypic and activity-based profiling of electrophilic fragments
Cell Chemical Biology
March 20, 2025
Yizhen Jin, Sadhan Jana, Mikail E. Abbasov, Hening Lin
ambient temperature. Samples were next transferred onto
Micro Bio-Spin Chromatography Columns
(
Bio-Rad
,
7326204
) and washed with the wash buffer (3 × 50 mM TEAB, 150 mM NaCl, 0.1% Igepal CA-630), DPBS (3×), and water
(15)
Sulfinyl Aziridines as Stereoselective Covalent Destabilizing Degraders of the Oncogenic Transcription Factor MYC
bioRxiv : the preprint server for biology
February 27, 2025
Rosen HT, Li K, Li EL, Currier B, Brittain SM, Garcia FJ, Beard DC, Haenni-Holzinger S, Dovala D, McKenna JM,
et al
.
streptavidin-agarose beads (
ThermoFisher
,
20353
) were washed with PBS using a Micro-Bio Spin Column (
Bio-Rad
,
7326204
) and vacuum manifold. 500 μL of PBS was added to the dissolved proteins, and then the washed beads were
(16)
Molecular mechanisms of CAND2 in regulating SCF ubiquitin ligases
Nat Commun
February 26, 2025
Kankan Wang, Lihong Li, Sebastian Kenny, Dailin Gan, Justin M. Reitsma, Yun Zhou, Chittaranjan Das, Xing Liu
buffer and 100 mM Tris-HCl (pH 8.0). The resin was subsequently transferred to a spin column (
Bio-Rad
,
7326204
) and incubated twice with 150 µL of 10% ammonium hydroxide for 5 min to elute the bound proteins. The
(17)
Specialized metabolome and transcriptome atlas of developing Arabidopsis thaliana seed under warm temperatures
Sci Data
February 20, 2025
Léa Barreda, Stéphanie Boutet, Delphine De Vos, Céline Boulard, Damaris Grain, Loïc Lepiniec, Massimiliano Corso
and RNAs dried prior to their resuspension in 40 µL of RNAse-free water. RNAs were purified by using
Micro Bio Spin Chromatography columns
(
BioRad
) previously pre-conditioned by adding 5 mg of PVPP and two consecutive washings with 400 µL
(18)
Force-bearing phagocytic adhesion rings mediate the phagocytosis of surface-bound particles
Nature communications
January 24, 2025
Kundu S, Pal K, Pyne A, Wang X.
diffuses to PBS and is extracted by spinning the diced gel solution through a column with a filter (
7326204
,
Bio-Rad
). The
purification
with
electrophoresis
can be skipped if the RGD-DNA purity checked by a low-scale
(19)
Chemical tools to define and manipulate interferon-inducible Ubl protease USP18
Nat Commun
January 22, 2025
Griffin J. Davis, Anthony O. Omole, Yejin Jung, Wioletta Rut, Ronald Holewinski, Kiall F. Suazo, Hong-Rae Kim, Mo Yang, Thorkell Andresson, Marcin Drag,
et al.
washed (4× 0.2% NP-40/PBS, 4x PBS, 4x ddH2O, 1x HEPES) by
centrifugation
(500 × g, 1 min, 4 °C) with
Micro Bio-Spin™ Chromatography Columns
(
Bio-rad
). After the final wash, the supernatant was removed, 50 μL of 100 mM of HEPES pH 7.4 was added,
(20)
A Label-Free Colorimetric Aptasensor for Flavokavain B Detection
Sensors (Basel)
January 19, 2025
Sisi Ke, Ningrui Wang, Xingyu Chen, Jiangwei Tian, Jiwei Li, Boyang Yu
(Grand Island, NY, USA). Streptavidin-coated agarose resin was obtained from Thermo Fisher Scientific.
Micro Bio-Spin chromatography columns
(500 μL) were sourced from
Bio-Rad
, and 2 ×
GoTaq Hot Start Colorless Master Mix
was acquired from
Promega
.
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
Micro Bio-Spin™ Chromatography Columns from Bio-Rad
Supplier Page
View Company Product Page
$165.00
Product Specs
Company Info
Citations
Reviews
Back To Top