Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Cell Biology
Biomolecules
Biomolecules
EnGenMutation Detection Kit
Supplier Images
EnGenMutation Detection Kit
EnGenMutation Detection Kit from New England Biolabs
(1)
Write a review
Citations:
(16)
$225.00 Inquire
from
New England Biolabs for
EnGenMutation Detection Kit
Description
EnGen Mutation Detection Kit - 25 rxns
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
EnGenMutation Detection Kit
Company
New England Biolabs
Price
$225.00 Inquire
Catalog Number
E3321S
Size
25 reactions
Applications
Functional Genomics
Temperature
-20 C
Add to Compare List
New England Biolabs
240 County Road
Ipswich
,
Massachusetts
1938
United States
Phone
: 800-632-5227
800-632-7799
978-921-1350
Company Profile
Website:
http://www.neb.com
Citations (16)
(1)
Neurotrophic Modulation Restores Motor and Developmental Defects in Zebrafish Models of ints11 Deficiency
J Neurochem
March 16, 2026
Anna Pistocchi, Elena Chiricozzi, Matilde Molteni, Gaia Galassi, Laura Mauri, Francesca Balistreri, Stefania Magri, Anna Marozzi, Franco Taroni, Alex Pezzotta
T7 endonuclease I
(T7EI) with the EnGen Mutation Detection Kit (
New England Biolabs
, Ipswich, UK; cat.no
E3321S
). Reaction products were resolved on 2% agarose gel to detect digested
PCR
fragments, indicating the
(2)
Sequential, chromosome‐specific glutamine synthetase double knockout with Cas‐ CLOVER establishes enhanced CHO platforms for cell line development
Biotechnology Progress
February 22, 2026
Cintia Gomez Limia, Valeriya Steffey, Hsueh Che Cheng, Daniel Machado, Thomas Hart, Mark Cameron McHargue, Corey Brizzee, Jack Crawford
(T7EI)
assay
Genome editing
efficiency was assessed using the EnGen® Mutation Detection Kit (
NEB
, Cat#
E3321S
). After DNA extraction, 100 ng of genomic DNA was used to perform target specific
PCR
, the corresponding
(3)
Evaluation of gene editing in CHO cells using the Cas‐ CLOVER system
Biotechnology Progress
February 8, 2026
Tiffany McLamarrah, Efecan Aral, Michael Hoffman, Jennifer Tedstone, Thomas King, Jason Vitko, Maria João Sebastião, Jose M. Escandell, Mafalda M. Dias, Iona McCall,
et al.
manufacturer's protocol. The mismatch
assay
was performed using the EnGen Mutation Detection Kit (Cat#
E3321S
,
NEB
) according to the manufacturer's instructions. Briefly, a region flanking GS exon 5 and the potential
(4)
Manipulation of Alternative Splicing of IKZF1 Elicits Distinct Gene Regulatory Responses in T Cells
Cells
January 24, 2026
Lucia Pastor, Jeremy R. B. Newman, Colin M. Callahan, Rebecca R. Pickin, Mark A. Atkinson, Suna Onengut-Gumuscu, Patrick Concannon
days post-
transfection
(
New England Biolabs
, Ipswich, MA, USA, EnGen® Mutation Detection Kit, Cat#
E3321S
). Cloned
Jurkat cell
lines were isolated by serial dilution in U-bottom 96-well plates and cultured
(5)
Heat shock induces alternative polyadenylation through dynamic DNA methylation and chromatin looping
Cell stress & chaperones
July 1, 2025
Fink EE, Zhang Y, Santo B, Siddavatam A, Ou R, Nanavaty V, Lee BH, Ting AH.
editing efficiency of the pooled cells was determined using the
T7 endonuclease I
(T7EI)
assay
(
NEB
#
E3321S
). Briefly, genomic DNA from
transfected
cells was amplified using primers flanking the sgRNA-targeted
(6)
Neuron–non‐neuron electrical coupling networks are involved in chronic stress‐induced electrophysiological changes in lateral habenular neurons
The Journal of Physiology
April 1, 2025
Kenji Yamaoka, Kanako Nozaki, Meina Zhu, Haruhi Terai, Kenta Kobayashi, Hikaru Ito, Miho Matsumata, Hidenori Takemoto, Shinya Ikeda, Yusuke Sotomaru,
et al.
the
PCR
products were denatured, digested at 37°C for 15 min with an EnGen Mutation Detection Kit (
E3321S
;
New England Biolabs
, Ipswich, MA, USA), and analysed by
electrophoresis
in 2% agarose gels stained
(7)
SLMAP3 is crucial for organogenesis through mechanisms involving primary cilia formation
Open biology
October 1, 2024
Dias AP, Rehmani T, Applin BD, Salih M, Tuana B.
was confirmed with T7 endonuclease-based EnGen Mutation Detection Kit (
New England Biolabs
, cat. no.
E3321S
). For
FGFR1OP2
-sgRNA#2, we used the following pair of primers: 5′-GATGGCCTGCTCTAGACACT and 5′-TGGCGGTGAAGGATGTCTTA;
(8)
SH-SY5Y human neuronal cells with mutations of the CDKN2B-AS1 gene are vulnerable under cultured conditions
Biochemistry and Biophysics Reports
July 1, 2024
Michiko Ohno-Oishi, Zou Meiai, Kota Sato, Seiya Kanno, Chihiro Kawano, Makoto Ishikawa, Toru Nakazawa
according to the manufacturer's protocol with the EnGen Mutation Detection Kit (
New England Biolabs
,
E3321S
). The density of the amplicon and digested band was determined with software (Image Lab 3.0; Bio-Rad). 2.9
(9)
CRISPR-Cas9-mediated deletion of carbonic anhydrase 2 in the ciliary body to treat glaucoma
Cell Reports Medicine
May 21, 2024
Jiaxuan Jiang, Kangjie Kong, Xiuli Fang, Deming Wang, Yinhang Zhang, Peiyuan Wang, Zefeng Yang, Yuwei Zhang, Xiaoyi Liu, Tin Aung,
et al.
mutations. Finally, the sample was digested with the EnGen Mutation Detection Kit (
New England BioLabs
,
E3321S
) for 15 min at 37°C followed by Proteinase K digestion for 5 min at 37°C, and the resulting products
(10)
Enhancer switching in cell lineage priming is linked to eRNA, Brg1’s AT-hook, and SWI/SNF recruitment
Molecular Cell
May 16, 2024
Dhurjhoti Saha, Srinivas Animireddy, Junwoo Lee, Anna Thommen, McKenzie M. Murvin, Yue Lu, J. Mauro Calabrese, Blaine Bartholomew
assays
MycoAlert,
Lonza
,cat#
LT07–218
QuickExtract DNA extraction kit,Lucigen,cat#QE09050 EnGen Mutation detection kit,
NEB
,cat#
E3321S
Alkaline
staining
kit,SBI,cat#AP100B-1 Qubit dsDNA HS kit,Thermo Fisher Scientific,cat#Q32581 NEB
(11)
Genome-wide CRISPR-Cas9 screen analyzed by SLIDER identifies network of repressor complexes that regulate TRIM24
iScience
July 21, 2023
Patel LR, Stratton SA, McLaughlin M, Krause P, Allton K, Rivas AL, Barbosa D, Hart T, Barton MC.
T7E1
assays
were performed using the EnGen® Mutation Detection Kit per manufacturers protocol (
NEB
E3321S
) and gene specific primers to amplify a ∼500bp region containing PAM site targeted by Synthego to perform
(12)
Membrane-Tethered Mucin 1 Is Stimulated by Interferon and Virus Infection in Multiple Cell Types and Inhibits Influenza A Virus Infection in Human Airway Epithelium
mBio
August 30, 2022
Iverson E, Griswold K, Song D, Gagliardi TB, Hamidzadeh K, Kesimer M, Sinha S, Perry M, Duncan GA, Scull MA.
Sorted transduced cells were frozen for later use or analyzed with an EnGen mutation detection kit (no.
E3321S
,
New England BioLabs
) for on-target
gene editing
confirmation (forward primer, 5′-AGC ACT TCT CCC CAG
(13)
Flow Assisted Mutation Enrichment (FAME): A highly efficacious and efficient method to enrich Double Knockouts (DKO) after gene editing
PLOS ONE
March 4, 2021
Michael Hansen, Xiaopin Cai, Sara Bowen, David A. Largaespada, Ming V. Li
(T7EI)
assay
The T7EI
assay
was conducted with kits purchased from
New England Biolabs
(Catalog #
E3321S
), according to manufacturer’s instruction. Briefly,
PCR
was conducted with provided high-fidelity polymerase
(14)
Development of a CRISPR-SaCas9 system for projection- and function-specific gene editing in the rat brain
Science advances
March 1, 2020
Sun H, Fu S, Cui S, Yin X, Sun X, Qi X, Cui K, Wang J, Ma L, Liu FY,
et al
.
sequence was amplified with
polymerase chain reaction (PCR
) by Q5 Hot Start High-Fidelity 2× Master Mix (
E3321S
,
New England Biolabs
) with the following program: preheat at 98°C for 30 s, 35 cycles of three-step
(15)
Niche stiffness underlies the ageing of central nervous system progenitor cells
Nature
September 5, 2019
Michael Segel et al.
28104
) and the surveyor
assay
was performed as directed from the Engen Mutation Detection Kit (
NEB
;
E3321S
). Samples were subsequently run on a 2% agarose gel and band intensity was measured using ImageJ. For
(16)
Sox9
regulates cell state and activity of embryonic mouse mammary progenitor cells
Communications biology
January 1, 2018
Kogata N, Bland P, Tsang M, Oliemuller E, Lowe A, Howard BA.
QuickExtract DNA Extraction Solution (QE0905T, Qiagen, Peterborough, UK) and EnGen™ Mutation Detection Kit (
E3321S
,
New England Biolabs
, Herts, UK) according to the manufacturer’s instructions. We tested four different
<<
<
>
>>
Reviews
Write a Review
(1)
12/2/2022
Good Kit for Measuring Editing Efficiency
Dimi Comfu
We were interested in studying the role of DNA methylation in the differentiation of of CD4 T-cells. CRISPR-Cas9 approaches were used to knock-out epigenetic enzymes in primary cells and cell lines. ...
Read Review
<<
<
>
>>
EnGenMutation Detection Kit from New England Biolabs
Price
$225.00
Inquire
Product Specs
Company Info
Citations
Reviews
Back To Top