Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
A Guide to Flow Cytometry
Flow Cytometers / Flow Cytometry Systems
MA900 Multi-Application Cell Sorter
Supplier Images
Published Figures
MA900 Multi-Application Cell Sorter
MA900 Multi-Application Cell Sorter from Sony Corporation
Be the first to write a review!
Citations:
(918)
Figures:
(7)
Inquire
from
Sony Corporation for
MA900 Multi-Application Cell Sorter
Description
MA900 multi-application cell sorter features ease of use, support for up to 12 fluorescence parameters and 4-way sorting.
Product Specs
Citations
Reviews
Product Specs
Item
MA900 Multi-Application Cell Sorter
Company
Sony Corporation
Price
Inquire
Catalog Number
MA900
Lasers
2 lasers
Excitation
405 nm (10 mW), 488 nm (36 mW), 638 nm (36 mW), 561 nm (36 mW)
Parameters
14 parameters / 12 fluorescence channels
Capacity
Tubes (0.5 mL, 1.5 mL, 5 mL, 15 mL)
Data Throughput
70,000 events/sec (max)
Dimensions
(WxDxH) 55 x 55 x 72 cm
Add to Compare List
Citations (918)
(1)
Oncolytic virotherapy with chimeric rVSV-NDV causes tumor-specific immunity in a DC-activation dependent manner
Molecular Therapy Oncology
September 17, 2026
Lorenz Hanesch, Nina Hartmann, Sonja Glauß, Tianle Feng, Jennifer Altomonte
CD11c and anti-mouse CD103 antibodies (both BioLegend, San Diego, CA, USA). Sorting was performed on an
MA900 Multi-Application Cell Sorter
(
Sony
Biotechnology, Champaign, IL, USA).
Leukocyte
suspensions derived from blood samples were first
(2)
Gene expression adaptation of metastases to their host tissue
iScience
August 21, 2026
Luise Nagel, Marten Wenzel, Sascha Hoppe, Mohammad Karimpour, Patrick S. Plum, Abdossamad Hamoudi, Israt Jahan, Sarah Schmitt, Marek Franitza, Roger Wahba,
et al.
cells were isolated from mixed populations via
fluorescence-activated cell sorting
(FACS) using a
Sony
MA900
cell sorter with a 100 μm nozzle to ensure gentle handling of viable cells. RFP-positive CRC cells were
(3)
AI-enabled discovery and biochemical optimization of minibinders targeting cancer cell-surface proteins
Nat Commun
August 20, 2026
Bianca Broske, Benjamin A. McEnroe, Sophie C. Frechen, Tim N. Kempchen, Caroline I. Fandrey, Elisabeth Tan, Dominic Ferber, Michelle C. R. Yong, Marie Kleinert, Julia M. Messmer,
et al.
immediately after
staining
for distinct APC-signal using the
fluorescence
-activated cell sorter
Sony
MA900
. Sorted cells were lysed in direct lysis buffer (1 mM CaCl2, 3 mM MgCl2, 1 mM EDTA, 1% (v/v) Triton
(4)
Multiscale integration of tissue and chromatin context converts cell heterogeneity into stable intestinal patterning
Cell
August 20, 2026
Cornelia Schwayer, Silvia Barbiero, David B. Brückner, Koen C. Oost, Clara Baader, Nicole A. Repina, Jinse Kim, Oscar E. Diaz, Isa Uccelli, Laura Capolupo,
et al.
a 30μm cell strainer. Single cells were sorted using a Becton Dickinson Influx cell sorter or
SONY
,
MA900
cell sorter equipped with a 100μm nozzle. Live single cells were gated based on DRAQ7
staining
, size,
(5)
Self-sufficient killing of malignant tumors by an engineered cancer-selective gene circuit
Cell Reports Medicine
August 18, 2026
Qi Liu, Qiqi Xiong, Guanglei Xie, Qidi Chen, Shujie Yang, Yuhang Wu, Liuqi Zhao, Ting Gao, Xinyuan Qiu, Jian Jiang,
et al.
lentiviral particles created with pQL80 as transfer plasmid. Following
flow cytometric
sorting using the
MA900 Multi-Application Cell Sorter
(
Sony
Biotechnology; San Jose, CA), the cell population showing strongest red
fluorescence
were harvested.
(6)
Identifying phenotype-genotype-function coupling in 3D organoid imaging using Shape, Appearance and Motion Phenotype Observation Tool (SPOT)
Nat Commun
August 17, 2026
Felix Y. Zhou, Brittany-Amber Jacobs, Adam Norton-Steele, Xiaoyue Han, Linna Zhou, Thomas M. Carroll, Carlos Ruiz Puig, Joseph Chadwick, Xiao Qin, Richard Lisle,
et al.
days. To generate a homogenous population of
organoids
positive for the fluorescent protein of interest, a
MA900 Multi-Application Cell Sorter
(
Sony
Biotechnology) was used.
Fluorescence
was detected within 24 h of lentiviral transduction. To
(7)
Hypoxia differentially affects coronary vessel formation during heart development
Cardiovascular Research
August 14, 2026
Sophie Payne, Susann Bruche, Dorota Szumska, Lucija Fleisinger, Alice Neal, Mark D Preston, Sarah De Val
cells were also prepared as controls for setting up the FACS machine. Cells were sorted using a
Sony
MA900
FACS Sorter, with gating set up first using an FSC-A vs. BSC-A plot to exclude cell debris, then an
(8)
Cell surface ADGRG1 and CD86 expression identifies antitumor CD4+ T cells in human cancer
Proc Natl Acad Sci U S A
August 11, 2026
Kyle J. Hitscherich, Aaron J. Dinerman, Abraham A. Hakim, Victoria Dulemba, Sivasish Sindiri, Billel Gasmi, Alakesh Bera, Jared J. Gartner, Todd D. Prickett, Zhiya Yu,
et al.
or CITE-seq as indicated in individual experiments. Cells were isolated via
flow cytometry
via
Sony
MA900 Multi-Application Cell Sorter
(Sony Biotechnology, San Jose, CA). Mean fluorescent intensity (MFI) gates for each population were
(9)
Lysosomal dysfunction drives a transcriptional and epigenetic signature characteristic of disease-associated microglia in neurodegenerative diseases
Immunity
August 11, 2026
Christopher D. Balak, Johannes C.M. Schlachetzki, Addison J. Lana, Elizabeth West, Christine Hong, Jordan DuGal, Yi Zhou, Benjamin Li, Nathanael J. Spann, Payam Saisan,
et al.
Cells were then washed and filtered through a 40 μm cell strainer. Sorting was performed on a
Sony
MA900
or Beckman Coulter MoFlo Astrios EQ cell sorter.
Microglia
were defined as events that were DAPI negative,
(10)
Nuclear compartmentalization at the G1/S transition plays a key role in DNA replication control
Nat Commun
August 10, 2026
Asami Oji, Kosuke Yusa, Izumi Noda, Takako Ichinose, Yoshiko Kondo, Ichiro Hiratani
incubated at 37 °C. After 10 min, cells were filtered through a cell strainer and sorted using a
Sony
MA900
cell sorter (purity mode). After sorting ~3 × 106 cells per FACS gate in three independent experiments,
(11)
Localized immunomodulation with cytokine-producing cells to mitigate foreign body responses in rodents and a nonhuman primate
Sci Adv
August 7, 2026
Boram Kim, Dilrasbonu Vohidova, Amanda Nash, Yuen San Chan, Samantha Fleury, Shravani Deo, Danna Murungi, Peter D. Rios, Ira Joshi, Hafsa Nasir,
et al.
were resuspended in
cell staining
buffer and run through a 40-μm filter before acquisition on a
Sony
MA900
. Single-color,
fluorescence
minus one (FMO) controls, as well as a negative unstained control, were
(12)
Genomic repeats for single-cell molecular recording
bioRxiv
August 7, 2026
Rachel K. Dveirin, Jessica D. Lin, Preeti Vyas, Jiaxi Lu, Yuqing Yan, Jennifer J. Lee, Xinzhong Dong, Sujatha Kannan, Ben Langmead, Sashank K. Reddy,
et al.
mCherry+ cells and
sequencing
of RGR loci All
flow cytometry
experiments were performed using a
Sony
MA900
system with 100-uM sorting chips (Sony). Prior to each sorting session, the instrument was calibrated
(13)
Human-specific SRGAP2 paralogs synchronize neotenic microglial maturation and synaptic development
Neuron
August 5, 2026
Carlos Diaz-Salazar, JaeYeon Kim, Marine Krzisch, Juyoun Yoo, Patricia R. Nano, Aparna Bhaduri, Rudolf Jaenisch, Mercedes Paredes, Franck Polleux
sorted directly into TRIzol (
Thermo Fisher Scientific
) as
CD11b
+, CD45low,
CX3CR1
+ cells on a
Sony
MA900
(SONY) sorter with a 100 μm
microfluidic
chip. TRIzol containing the cell lysates was mixed with chloroform
(14)
Brain metastasis-associated fibroblasts shape the tumour microenvironment to enhance cancer cell invasion
Brain Pathol
August 4, 2026
Barbora Výmolová, Lucie Pfeiferová, Tadeáš Karel Smetana, Petr Výmola, Nikola Ternerová, Michal Zubaľ, Michal Kolář, Jana Šáchová, Soňa Gyönyörová, Eva Balážiová,
et al.
cells/mL, and filtered through a cell strainer with 40 μm pores (VWR).
Cancer
cells were isolated using the
MA900 Multi‐Application Cell Sorter
(
SONY
), followed by
centrifugation
(300g, 5 min, 4°C) and resuspension in 400 μL of PBS. The purity
(15)
Tyro3 facilitates cytoplasmic delivery of extracellular vesicle contents and antigen presentation via major histocompatibility complex class I in dendritic cells
PLoS One
August 4, 2026
Takashi Koyama, Katsuhiko Kojima, Koki Maeda, Takahide Matsui, Hitomi Kosai, Noriko Ishida, Eiji Morita, Mitsunori Fukuda, Nobuyuki Tanaka
from FUJIFILM Wako), followed by limiting dilution or single-
cell sorting
using a
SONY
cell sorter (
MA900
). Preparation of recombinant proteins The expression plasmids used in this study for the preparation
(16)
Liver Endothelia Orchestrate MASH-Associated Macrophage Zonation Through FSTL1-ITGA4 Axis
Adv Sci (Weinh)
August 3, 2026
Lin Sun, Zhensheng Yue, Zhiqiang Fang, Hao Xu, Wei Du, Yuwei Ling, Jingjing Liu, Ping Song, Fei He, Juanli Duan,
et al.
BioLegend
). Viability was assessed using 7‑AAD (
420404
,
BioLegend
).
Flow cytometry
was performed on a
Sony
MA900
, and data were analyzed with Cell Sorter software (Sony). A total of 50,000 events were acquired. The
(17)
Dysregulated ITGA3/FAK/YAP axis mediates impaired alveolar type II epithelial cells function in COPD
Journal of Advanced Research
August 1, 2026
Li Liu, Suye Zhong, Tengfei Zhou, Yixing Wu, Weiping Hu, Xiao Wang, Yue Ren, Kankai Wang, Xinhua Lin, Jing Zhang
Biolegend, USA) and Lysotracker (40738ES50, YEASEN, China)
for flow cytometry
analysis and sorting using
MA900 Multi-Application Cell Sorter
(
Sony
Biotechnology). Data was analyzed using FlowJo software. Alveolar
organoid culture
Freshly
fluorescence-activated cell sorting
(18)
A comprehensive map of missense trafficking variants in rhodopsin and their response to pharmacologic correction
Sci Adv
July 31, 2026
Kannan V. Manian, Connor H. Ludwig, Yan Zhao, Nathan S. Abell, Robert Warneford-Thomson, Henry Chan, Zachary O. Casey, Xiaoping Yang, David E. Root, Matthew L. Albert,
et al.
strainer (
Corning
,
352340
) before acquisition and sorting using a
Sony
cell sorter machine (SH800 or
MA900
). The sorting utilized a 100-micron nozzle, with the sort mode set to purity. The flow-rate was maintained
(19)
Anti-malaria antibody engineering broadens recognition motifs and reveals new homotypic interactions that enhance protective breadth
Nature Communications
July 28, 2026
Jihwan Chun, Prabhanshu Tripathi, Yevel Flores-Garcia, Bharat Madan, Gene A. Lee, Ahmed S. Fahad, Haotian Lei, I-Ting Teng, Nicholas K. Hurlburt, Barbara J. Flynn,
et al.
studies16,20. Affinity evaluation and
fluorescence-activated cell sorting
(FACS) were performed using a
SONY
MA900
flow cytometer
, as in prior reports23,27. Yeast display libraries were incubated in SGDCAA induction
(20)
Distinct metabolic dependency on BCAA defines cancer stemness and malignancy in human triple-negative breast cancer
Cell Reports
July 28, 2026
Kenkyo Matsuura, Ririko Shinonaga, Mizuki Yamamoto, Yoshiki Yamamoto, Hsin Chen, Ayaka Maeno, Kayo Okuda, Haruki Inoue, Sota Imotani, John Glushka,
et al.
manufacturer’s instructions.
MDA-MB-231 cells
with
OLIVe
were isolated by single
cell sorting
on a Cell Sorter
MA900
(
Sony
), and several
clones
were established and confirmed to respond similarly across varying BCAA concentrations
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
MA900 Multi-Application Cell Sorter from Sony Corporation
Price
Inquire
Product Specs
Citations
Reviews
Back To Top