Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Articles
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Multimedia
Biocompare Webinars
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Tech Talks
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Resources
Promotions
Events
AACR SPOTLIGHT
Register
Sign In
Biocompare
Products
Lab Equipment
Supplies & Consumables
High Sens. RNA ScreenTape Sample Buffer
Supplier Images
High Sens. RNA ScreenTape Sample Buffer
High Sens. RNA ScreenTape Sample Buffer from Agilent Technologies
Be the first to write a review!
Citations:
(34)
Supplier Page
Supplier Page from
Agilent Technologies for
High Sens. RNA ScreenTape Sample Buffer
Get Pricing
Description
For the high sensitivity analysis of total RNA down to a sensitivity of 100 pg/µL. Sample Buffer only. To order with 5067-5579 and 5067-5581.
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
High Sens. RNA ScreenTape Sample Buffer
Company
Agilent Technologies
Price
Supplier Page
View Company Product Page
Catalog Number
5067-5580
Sensitivity
100 pg/µL
Sample Volume
2 µL
Concentration
1 mM EDTA, 10 mM Tris
Add to Compare List
Agilent Technologies
5301 Stevens Creek Blvd
Santa Clara
,
California
95051
United States
Phone
: +1 877-424-4536
Company Profile
Website:
www.agilent.com
Citations (34)
(1)
Universal method for the isolation of microvessels from frozen brain tissue: A proof-of-concept multiomic investigation of the neurovasculature
Brain, Behavior, & Immunity - Health
December 1, 2023
Marina Wakid, Daniel Almeida, Zahia Aouabed, Reza Rahimian, Maria Antonietta Davoli, Volodymyr Yerko, Elena Leonova-Erko, Vincent Richard, René Zahedi, Christoph Borchers,
et al.
cat. no.
5067–5577
) or TapeStation High
Sensitivity
RNA ScreenTape sample buffer
(
Agilent
, cat. no.
5067–5580
)•SMARTer Stranded Total
RNA-Seq
Kit v3 - Pico Input Mammalian (Takara Bio Inc., cat. no. 634485)•NucleoMag
(2)
Transcriptomes of aging brain, heart, muscle, and spleen from female and male African turquoise killifish
Scientific Data
October 12, 2023
Alan Xu, Bryan B. Teefy, Ryan J. Lu, Séverine Nozownik, Alexandra M. Tyers, Dario R. Valenzano, Bérénice A. Benayoun
instructions. RNA quality was assessed using high
sensitivity
RNA screen tapes (
Agilent
cat#
5067–5579
,
5067–5580
) on
Agilent
Tapestation 4200 to obtain the RNA Integrity Number (RIN). Samples with a RIN score of <4
(3)
Untargeted metagenomics protocol for the diagnosis of infection from CSF and tissue from sterile sites
Heliyon
September 9, 2023
Laura Atkinson, Jack CD. Lee, Alexander Lennon, Divya Shah, Nathaniel Storey, Sofia Morfopoulou, Kathryn A. Harris, Judy Breuer, Julianne R. Brown
RNA ladder,
Agilent Technologies
,
5067–5581
High
sensitivity
RNA sample buffer,
Agilent Technologies
,
5067–5580
High
sensitivity
RNA screen tape,
Agilent Technologies
,
5067–5579
KAPA RNA HyperPrep Kit
,
Roche
,8098093702
KAPA RNA HyperPrep Kit
(4)
Calling Cards: a customizable platform to longitudinally record protein-DNA interactions over time in cells and tissues
bioRxiv
June 15, 2023
Allen Yen, Chase Mateusiak, Simona Sarafinovska, Mariam A. Gachechiladze, Juanru Guo, Xuhua Chen, Arnav Moudgil, Alexander J. Cammack, Jessica Hoisington-Lopez, MariaLynn Crosby,
et al.
C2432) RNA kit TURBO DNase High
Sensitivity
RNA ScreenTape
(
Agilent
5067-5579
) and Sample Buffer (
Agilent
5067-5580
) Qubit RNA
Assay
Kits (
ThermoFisher
Q32852
,
Q10211
, or Q33224) Refrigerated centrifuge (Eppendorf 5430R) Rotor
(5)
Moderate intrinsic phenotypic alterations in C9orf72 ALS/FTD iPSC-microglia despite the presence of C9orf72 pathological features
Frontiers in Cellular Neuroscience
June 6, 2023
Ileana Lorenzini, Eric Alsop, Jennifer Levy, Lauren M. Gittings, Deepti Lall, Benjamin E. Rabichow, Stephen Moore, Ryan Pevey, Lynette M. Bustos, Camelia Burciu,
et al.
and quality with Agilent High
Sensitivity
RNA ScreenTape
and buffer (
Agilent
, Cat. No.
5067-5579
&
5067-5580
). For each RNA sample, an indexed, Illumina-compatible, double-stranded cDNA whole transcriptome library
(6)
The scaffolding function of LSD1/KDM1A reinforces a negative feedback loop to repress stem cell gene expression during primitive hematopoiesis
iScience
January 20, 2023
Mattie J. Casey, Alexandra M. Call, Annika V. Thorpe, Cicely A. Jette, Michael E. Engel, Rodney A. Stewart
was not utilized. RNA quality was assessed using the Agilent ScreenTape
Assay
(
Agilent
5067-5579
and
5067-5580
) and the Illumina TruSeq Stranded Total RNA kit with Ribo-Zero Gold (Illumina 20020598) was used for
(7)
PepSeq: a fully in vitro platform for highly multiplexed serology using customizable DNA-barcoded peptide libraries
Nature Protocols
November 16, 2022
Sierra N. Henson, Evan A. Elko, Piotr M. Swiderski, Yong Liang, Anna L. Engelbrektson, Alejandra Piña, Annalee S. Boyle, Zane Fink, Salvatore J. Facista, Vidal Martinez,
et al.
cat. no.
5067-5579
) High
Sensitivity
RNA ScreenTape sample buffer
(store at 4 °C;
Agilent
, cat. no.
5067-5580
) RNA ScreenTape (store at 4 °C;
Agilent
, cat. no.
5067-5576
)
RNA ScreenTape sample buffer
(store
(8)
Dual genome-wide coding and lncRNA screens in neural induction of induced pluripotent stem cells
Cell Genomics
November 9, 2022
David Wu, Aunoy Poddar, Elpiniki Ninou, Elizabeth Hwang, Mitchel A. Cole, S. John Liu, Max A. Horlbeck, Jin Chen, Joseph M. Replogle, Giovanni A. Carosso,
et al.
Barcoding,10x Genomics,"Cat# PN-1000075, PN-1000153, PN-1000079" High
Sensitivity
RNA ScreenTape,
Agilent
,Cat#
5067-5580
High
Sensitivity
D1000 DNA ScreenTape,
Agilent
,Cat#
5067-5584
High
Sensitivity
D5000 DNA ScreenTape,
Agilent
,Cat#
(9)
Hand Dissection of
Caenorhabditis elegans
Intestines
Journal of Visualized Experiments
October 3, 2022
Jessica L. Hill, Andrew Moore, Robert T. P. Williams, Erin Osborne Osborne Nishimura
assesment of total RNA quality and quantity High
Sensitivity
RNA ScreenTape Sample Buffer
,
Agilent
,
5067–5580
,for assesment of total RNA quality and quantity HostZERO Microbial DNA Kit,Zymo Research,D4310,Isolation
(10)
Distinct gene expression dynamics in developing and regenerating crustacean limbs
Proceedings of the National Academy of Sciences
July 5, 2022
Chiara Sinigaglia, Alba Almazán, Marie Lebel, Marie Sémon, Benjamin Gillet, Sandrine Hughes, Eric Edsinger, Michalis Averof, Mathilde Paris
quality was assessed with TapeStation 2200 (
Agilent
RNA ScreenTape High
Sensitivity
System: #
5067-5579
, #
5067-5580
, and #
5067-5581
), and 1 ng of RNA was used for
cDNA synthesis
(SMART-Seq v4 Ultra Low Input RNA Kit;
(11)
Nano pom-poms prepared exosomes enable highly specific cancer biomarker detection
Communications biology
July 4, 2022
He N, Thippabhotla S, Zhong C, Greenberg Z, Xu L, Pessetto Z, Godwin AK, Zeng Y, He M.
quantified by High
Sensitivity
RNA ScreenTape
Assay
using Agilent TapeStation 2200 (
Agilent
, USA,
5067-5579
,
5067-5580
). Total RNA was stored at −80 °C until small
RNA Library preparation
. The QIAseq
miRNA
Library is prepared
(12)
Bacterial growth in multicellular aggregates leads to the emergence of complex life cycles
Current Biology
July 1, 2022
Julia A. Schwartzman, Ali Ebrahimi, Grayson Chadwick, Yuya Sato, Benjamin R.K. Roller, Victoria J. Orphan, Otto X. Cordero
Santa Clara, CA, USA",Cat#
5067- 5579
HS RNA screen tape buffer,"
Agilent
, Santa Clara, CA, USA",Cat#
5067- 5580
HS RNA screen tape ladder,"
Agilent
, Santa Clara, CA, USA",Cat#
5067- 5581
Ribominus
Yeast
and
Bacteria
(13)
Impact of secondary TCR engagement on the heterogeneity of pathogen-specific CD8+ T cell response during acute and chronic toxoplasmosis
PLoS pathogens
June 1, 2022
Shallberg LA, Phan AT, Christian DA, Perry JA, Haskins BE, Beiting DP, Harris TH, Koshy AA, Hunter CA.
ScreenTape,
Agilent
,
5067–5579
High
Sensitivity
RNA Ladder,
Agilent
,
5067–5581
High
Sensitivity
RNA Buffer,
Agilent
,
5067–5580
AMPure XP beads,
Beckman Coulter
,
A63881
Foxp3 / Transcription Factor Staining Buffer Set,
eBioscience
,
00-5523-00
Reagents.
(14)
Zebrafish models of
alx
-linked frontonasal dysplasia reveal a role for Alx1 and Alx3 in the anterior segment and vasculature of the developing eye
Biology Open
May 15, 2022
Baul Yoon et al.
Kit (Qiagen
74134
) and RNA quality was assessed by Agilent High
Sensitivity
RNA ScreenTape (
Agilent
,
5067-5580
). cDNA libraries were prepared using the NEBNext® Ultra™ II Directional RNA Library kit (
NEB
,
E7765S
)
(15)
Secretory defects in pediatric osteosarcoma result from downregulation of selective COPII coatomer proteins
iScience
April 15, 2022
Rachael K. Wood, Ashley R. Flory, Melissa J. Mann, Lindsay J. Talbot, Linda M. Hendershot
RiboGreen
assay
,
Life Technologies
,
R32700
High Sensitivity RNA ScreenTape assay
,
Agilent
,
5067-5579
;
5067-5580
LabChip RNA Pico
Sensitivity
assay
,
Perkin Elmer
,
CLS960012
TruSeq Stranded Total
RNA Library Prep
Kit,Illumina,20020599 Caliper
(16)
Synthetic DNA spike-ins (SDSIs) enable sample tracking and detection of inter-sample contamination in SARS-CoV-2 sequencing workflows
Nature Microbiology
January 1, 2022
Kim A. Lagerborg et al.
RNA using a T7 transcription kit (NEB E2050), quantified by RNA screen tape (
Agilent
5067–5579
and
5067–5580
), then diluted in water to 10fM (6,000 copies/μL), 1fM (600 copies/μL), 100aM (60 copies/μL), and 10aM
(17)
The Extracellular Milieu of
Toxoplasma
's Lytic Cycle Drives Lab Adaptation, Primarily by Transcriptional Reprogramming
mSystems
December 21, 2021
Vincent A. Primo, Yasaman Rezvani, Andrew Farrell, Connor Q. Murphy, Jingjing Lou, Amir Vajdi, Gabor T. Marth, Kourosh Zarringhalam, Marc-Jan Gubbels
measuring the RNA integrity number (RIN) using
Agilent
’s TapeStation (kit catalog no.
5067-5579
and
5067-5580
). Illumina’s
library prep
kit (RS-122-2102) was used to generate ∼281-bp cDNA fragments, which were
(18)
Genome annotation with long RNA reads reveals new patterns of gene expression and improves single-cell analyses in an ant brain
BMC Biology
December 1, 2021
Emily J. Shields, Masato Sorida, Lihong Sheng, Bogdan Sieriebriennikov, Long Ding, Roberto Bonasio
Scientific) and RNA integrity was checked using High
Sensitivity
RNA ScreenTape (
Agilent
#
5067-5579
,
5067-5580
,
5067-5581
) on a TapeStation 2200 or 4200 (Agilent). 250–500 ng extracted RNA was used to prepare libraries
(19)
Defining genome-wide CRISPR–Cas genome-editing nuclease activity with GUIDE-seq
Nature Protocols
December 1, 2021
Nikolay L. Malinin et al.
Sensitivity
Screen Tape (
Agilent
cat. no
5067-5579
) RNA High
Sensitivity
Sample Buffer (
Agilent
cat. no.
5067-5580
)
Mammalian Cell culture
and nucleofection 24 Well
Cell Culture
Plate, Flat Bottom with Lid,
Tissue Culture
(20)
Wisdom of the crowds: A suggested polygenic plan for small-RNA-mediated regulation in bacteria
iScience
October 22, 2021
Omer Goldberger, Jonathan Livny, Roby Bhattacharyya, Orna Amster-Choder
Kit,Illumina,Cat#MRZB12424 SMARTScribe Reverse Transcriptase,Takara Bio,Cat#639538 High
Sensitivity
RNA Screentape reagent,
Agilent
,Cat#
5067-5580
RNA Clean & Concentrator Kit,
Zymo Research
,Cat#
R1013
AccuPrime Taq HiFi Kit,
Life Technologies
,Cat#
12346094
High
Page
<<
<
1
2
>
>>
Reviews
Be the First to Write a Review!
High Sens. RNA ScreenTape Sample Buffer from Agilent Technologies
Supplier Page
View Company Product Page
Product Specs
Company Info
Citations
Reviews
Back To Top