Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Research Areas
ELISA
Western Blot
3D Cell Culture
Digital PCR
Quantitative PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
White Papers
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Antibodies
Antibodies
Salmonella Antibody
Salmonella Antibody from Thermo Fisher Scientific
Be the first to write a review!
Citations:
(8)
Supplier Page
Supplier Page from
Thermo Fisher Scientific for
Salmonella Antibody
Thermo Fisher Scientific's
Salmonella Antibody
is a Rabbit Polyclonal antibody. This antibody has been shown to work in applications such as: Immunocytochemistry, and Immunoprecipitation.
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
Salmonella Antibody
Company
Thermo Fisher Scientific
Price
Supplier Page
Catalog Number
PA1-20811
Clonality
Polyclonal
Quantity
500 µL
Reactivity
Bacteria
Format
PBS with 0.1% sodium azide; pH 7.2
Applications
Immunocytochemistry, Immunoprecipitation
Conjugate/Tag
Unconjugated
Target
Salmonella
Isotype
IgG
Concentration
5 mg/mL
Host
Rabbit
Immunogen
Mixture of S. enteriditis, S. typhimurium & S. heidelburg
Purity
IgG fraction
Antibody Type
Primary
Storage
Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles
Add to Compare List
Thermo Fisher Scientific
Thermo Fisher Scientific
81 Wyman Street
Waltham
,
MA
02451
United States
Phone
: 800-678-5599
Fax: 800-331-2286
Company Profile
Website:
www.thermofisher.com
Citations (8)
(1)
TLR-mediated aggresome-like induced structures comprise antimicrobial peptides and attenuate intracellular bacterial survival
Molecular biology of the cell
March 1, 2024
Bhatnagar A, Chopra U, Raja S, Das KD, Mahalingam S, Chakravortty D, Srinivasula SM.
Sigma-Aldrich
).
Immunofluorescence
and
Microscopy
To visualize internalized STM,
bacteria
were stained using
Salmonella
Polyclonal (
PA1-20811
,
Thermo
) antibody (
1:1000
) and Alexa Fluor 568
goat
antirabbit antibody (
1:1000
), wherever mentioned.
(2)
Hypoxia exacerbates intestinal injury and inflammatory response mediated by myeloperoxidase during Salmonella Typhimurium infection in mice
Gut Pathogens
November 30, 2023
Qinfang Zhu, Ying Han, Xiaozhou Wang, Ruhan Jia, Jingxuan Zhang, Meiheng Liu, Wei Zhang
spleen
were incubated with
Salmonella
rabbit antibody (
Thermo Fisher Scientific
, Waltham, MA, USA;
PA1-20811
) and
fluorescein goat anti-rabbit IgG (H + L
) (
Thermo Fisher Scientific
;
F-2765
). The distribution of
(3)
Vaccine-Induced Adverse Effects in Cultured Neuroblastoma 2A (N2A) Cells Duplicate Toxicity of Serum from Patients with Gulf War Illness (GWI) and Are Prevented in the Presence of Specific Anti-Vaccine Antibodies
Vaccines
May 18, 2020
Tsilibary EC, Souto EP, Kratzke M, James LM, Engdahl BE, Georgopoulos AP.
No.
11053-RP01
),
strains
of
influenza
(polyclonal,
Sino Biological
, Wayne, PA, USA); anti-
Salmonella
(Cat. No.
PA1-20811
, polyclonal,
ThermoFisher Scientific
, Rockford, IL, USA); anti-Japanese encephalitis virus (Cat. No.
PA5-32237
,
(4)
Detection of BCG bacteria using a magnetoresistive biosensor: A step towards a fully electronic platform for tuberculosis point-of-care detection
Biosensors and Bioelectronics
February 15, 2018
Teresa G. Barroso, Rui C. Martins, Elisabete Fernandes, Susana Cardoso, José Rivas, Paulo P. Freitas
PA1-73136
, 4–5 mg/ mL), anti-M. tuberculosis (
anti-Mtb
,
PA1-7260
, 4–5 mg/mL) and antiSalmonella (anti-Salm,
PA1-20811
, 1 mg/mL), were washed from their preservative solution by filtering with Millipore centrifugal filters (100
(5)
Detecting Antibody-Labeled BCG MNPs Using a Magnetoresistive Biosensor and Magnetic Labeling Technique
Journal of Nano Research
October 1, 2015
Teresa R.G. Barroso, Verónica C. Martins, Filipe Cardoso, Susana Cardoso, Jorge Pedrosa, Margarida Correia-Neves, José Rivas, Paulo P. Freitas
conjugated anti – M. tuberculosis (
anti-Mtb
bio,
PA1-73136
, 4-5 mg/mL) and antiSalmonella PAbs (anti-Salm,
PA1-20811
, 1 mg/mL), were purchased from
Thermo Scientific
. The
purification
of the PAbs was achieved by filtering
(6)
Detecting Antibody-Labeled BCG MNPs Using a Magnetoresistive Biosensor and Magnetic Labeling Technique
Journal of Nano Research
July 1, 2015
Teresa R.G. Barroso, Verónica C. Martins, Filipe Cardoso, Susana Cardoso, Jorge Pedrosa, Margarida Correia-Neves, José Rivas, Paulo P. Freitas
conjugated anti – M. tuberculosis (
anti-Mtb
bio,
PA1-73136
, 4-5 mg/mL) and antiSalmonella PAbs (anti-Salm,
PA1-20811
, 1 mg/mL), were purchased from
Thermo Scientific
. The
purification
of the PAbs was achieved by filtering
(7)
A bacteriophage detection tool for viability assessment of Salmonella cells
Biosensors & bioelectronics
February 15, 2014
Fernandes E, Martins VC, Nóbrega C, Carvalho CM, Cardoso FA, Cardoso S, Dias J, Deng D, Kluskens LD, Freitas PP,
et al
.
gun. A
phage
solution in MOPS buffer ( 1
1010
phages
/mL) or a polyclonal anti-
Salmonella
antibody (
PA1-20811
,
Thermo
Scientific) in PB solution (200 mg/mL) was then spotted in discrete areas of the substrate (
(8)
Interaction of the Salmonella Typhimurium effector protein SopB with host cell Cdc42 is involved in intracellular replication
Molecular microbiology
June 1, 2011
Rodríguez-Escudero I, Ferrer NL, Rotger R, Cid VJ, Molina M.
<<
<
>
>>
Reviews
Be the First to Write a Review!
Salmonella Antibody from Thermo Fisher Scientific
Supplier Page
Product Specs
Company Info
Citations
Reviews
Back To Top