Welcome Guest
Sign In
Register
Products
Popular Categories
Antibody Search
ELISA Kit Search
Biomolecules
Flow Cytometers
Thermal Cyclers
Microscopes
Transfection Reagents
Featured Products
New Products
Applications
ELISA
Western Blot
3D Cell Culture
PCR
Quantitative PCR
Digital PCR
Cell and Gene Therapy
In Vivo Models
Resources
eBooks
Bench Tips
Tech Insights
Editorial Articles
News
Product Reviews
Future Lab
Application Notes
Infographics
Events
Promotions
Multimedia
Biocompare Webinars
Technologies Transforming Precision Medicine
Immunotherapy
Reproducibility
Transformative Technologies
Podcasts
Bench Tip Videos
All Videos and Webinars
Life Science Webinars
Write a Review
Antibodies
Kits/Reagents
Equipment
Services
Register
Sign In
Biocompare
Products
Lab Equipment
Cell Analysis
Spatial Biology
Spatial Biology Platforms
Hyperion+™ Imaging System
Supplier Images
Published Figures
Hyperion+™ Imaging System
Hyperion+™ Imaging System from Standard BioTools Inc.
Be the first to write a review!
Citations:
(225)
Figures:
(7)
Get Pricing
Get Pricing from
Standard BioTools Inc. for
Hyperion+™ Imaging System
Supplier Page
Description
The Hyperion+™ Imaging System uses Imaging Mass Cytometry™ (IMC™) to visualize the complex spatial biology of the tissue microenvironment.
Product Specs
Company Info
Citations
Reviews
Product Specs
Item
Hyperion+™ Imaging System
Company
Standard BioTools Inc.
Price
Get Pricing
Get Quote for this Product
Catalog Number
Hyperion+
Method
Imaging mass cytometry (CyTOF) using mass-tagged antibodies; 40+ protein marker detection
Scale
Whole tissue, single cell
Quantity
EA
Add to Compare List
Standard BioTools Inc.
2 Tower Place, Suite 2000
South San Francisco
,
California
94080
United States
Phone
: 650 266 6000 | Main
866 359 4354 | Toll-free
Company Profile
Website:
http://standardbio.com
Citations (225)
(1)
Spatial omics illuminates tumor heterogeneity
Cell Reports Methods
August 17, 2026
Neha Srinivas, Serap Erdogmus, Gurkan Mollaoglu
PhenoCycler. MS-based methods include
imaging mass cytometry
(IMC, commercially available as
Standard BioTools
Hyperion
)20 and multiplexed ion beam imaging (MIBI),21 where tissue is stained with a panel of metal-conjugated
(2)
Impact of Photodynamic Diagnosis on Immune Cell Infiltration in BCG-treated Non-muscle-invasive Bladder Cancer
Eur Urol Open Sci
August 8, 2026
Tine Ginnerup Andreasen, Trine Strandgaard, Tessa Jane Divita, Kristine Young-Halvorsen, Anders Neijber, Lars Dyrskjøt
applied to assess associations between PDD use and
T-cell
exhaustion [15]. IMC was performed using the
Hyperion
platform (
Standard Biotools
) for 36
cancer
- and immunology-related protein markers. Cell types were
(3)
Amelioration of Acute Oxazolone-Induced Colitis via Oral Administration of EPICERTIN, a Mucosal Healing Biotherapeutic for Inflammatory Bowel Disease
Biomedicines
August 6, 2026
Wendy M. Kittle, Micaela A. Henderson, Noel Verjan Garcia, Hong Li, Katarina L. Mayer, Jimmy F. Cifuentes Jimenez, Kelly M. Lee, Kavitha Yaddanapudi, Nobuyuki Matoba
Cell-ID™ Intercalator-Ir (Standard BioTools, South San Francisco, CA, USA). Tissues were imaged on a
Hyperion Imaging System
(
Standard BioTools
), and image analysis was performed using MCD Viewer (version 1.0.5, Standard BioTools)
(4)
An Integrated Spatial Multi-Omics Workflow for Sequential RNA and Protein Profiling in FFPE Tumor Tissue
Cancer Res Commun
August 1, 2026
Merrin Mary Eapen, Qanber Raza, Lucy Chhuo, Annabel Faulkner, Abhishek K. Singh, Hao Xu, Atefeh Khakpoor, Erin Coll, Liang Lim, Nick Zabinyakov,
et al.
wash, slides were dried and stored at 4°C. Image acquisition was performed using the
Standard BioTools
Hyperion
XTi Imaging System (RRID: SCR_023195). Low-resolution scans of whole slides were acquired using preview
(5)
Dissecting Immune Determinants in Lesional Skin of Cutaneous T-Cell Lymphoma During Mogamulizumab Therapy
Cancers (Basel)
July 21, 2026
Xiao Ni, Wei Han, Niharika Kunta, Meghali Goswami, Jared K. Burks, Ye Zheng, Youn H. Kim, Madeleine Duvic
to IMC image acquisition. 2.5. IMC Image Acquisition
Imaging mass cytometry
was performed on the
Hyperion
™ XTi Imaging System (
Standard BioTools
, Boston, MA, USA) at a laser repetition rate of 200 Hz by the
(6)
Spatial Omics Technologies in Glioblastoma Research: Principles, Applications, and Best Practices
Genes (Basel)
July 18, 2026
Maxime Vanmechelen, Chiara Caprioli, Paul M. Clement, Ann Hoeben, Frederik De Smet
protein,Targeted,Single-cell,100+ proteins,FFPE & fresh frozen,Very high protein plexity,Long imaging runs
Hyperion
MIBI-TOF (
Standard Biotools
),Metal-tagged antibodies,Protein,Targeted,~200 nm–10 µm,40–50 proteins,FFPE
(7)
Epigenetic signatures mark early peripheral human B lineage bifurcation and differential transcriptional profiles in mature populations
Nature Communications
July 14, 2026
Chiara Dionisi, Audrey Kelly, Michael J. Pitcher, Sherine H. Kottoor, Alana Dalton, Lucia Montorsi, Pawan Dhami, Michelle Kleeman, Richard J. Ellis, Cynthia Bishop,
et al.
Iridium Cell-ID Intercalator-Ir (Cat.N. 201192 A,
Standard BioTools
). Data acquisition was conducted on a
Hyperion Imaging System
(Fluidigm). Regions of up to 1 mm2 were selected and laser-ablated at 200-Hz frequency at 1 μm/pixel
(8)
A tumor profiling resource for ovarian cancer: insights into chemotherapy-driven heterogeneity and personalized treatment strategy
Nature Communications
July 13, 2026
Francis Jacob, Rebekka Wegmann, Joanna Ficek-Pascual, Ulrike Lischetti, Jack Kuipers, Stéphane Chevrier, Michael Prummer, Nora C. Toussaint, Ilaria Alborelli, Ricardo Coelho,
et al.
and dried with compressed air.
Imaging mass cytometry
The IMC
data collection
was performed using a
Hyperion Imaging System
from
Standard BioTools
, operating at a laser frequency of 200 Hz. Raw image data were transformed into
(9)
Spatial mapping and senolytic targeting of senescent and disease-associated microglia in aged mouse brain white matter
Nat Aging
July 13, 2026
Chase M. Carver, Paul T. Gomez, Sonia L. Rodriguez, James T. Redden, Amanda S. Latham, Yooree Ha, Jennifer M. Kachergus, Yi Liu, Ji Shi, Tommy Tran,
et al.
each metal-conjugated antibody, distinguished by time-of-flight mass cytometer, were acquired by the
Hyperion Imaging System
(
Standard BioTools
), reconstructed into an image. Representative images were converted to OME.TIFF files
(10)
Hypoxia shapes both therapeutic response and resistance in metastatic clear cell renal cell carcinoma
Cancer Cell
July 13, 2026
Lynda Vuong, Andrew E. Cornish, Jennifer Pfeil, Yash Khandwala, Hui Jiang, Doris X.T. Zheng, Eduardo A. Mascareno, Nicole Rittenhouse, Phillip M. Rappold, Josef Leibold,
et al.
control adult
tonsil
and representative ccRCC tissues samples. Image acquisition was conducted using the
Hyperion
XT and XTi Imaging Systems (
Standard BioTools
) at 1 μm resolution and 800 Hz
laser ablation
. Acquisition
(11)
A pilot imaging mass cytometry study of cutaneous nerve-immune cell interactions in post-herpetic neuralgia
Front Immunol
July 8, 2026
Siddhesh N. Telang, Jackson F. Karrasch, Philip M. Finch, Stefanie S. Kogias, Thomas R. O'Neil, Anthony L. Cunningham, Andrew N. Harman, Peter D. Drummond, Paul J. Austin
Intercalator-Ir (DVS Sciences, 201192A), rinsed, and air-dried. All immunolabelled sections were imaged using a
Hyperion™ Imaging System
(
Standard BioTools
). Regions of interest spanning the dermal-epidermal border were selected following
(12)
TERT drives liver tumorigenesis beyond telomere elongation
Life Sci Alliance
July 2, 2026
Laura Braud, Julien Vernerey, Arnaud Guille, Pierre Cordier, Clémence Ginet, Tom Egger, Manuel Bernabe, Dmitri Churikov, Quentin Da Costa, Aïda Meghraoui,
et al.
signature was from Mitsuishi et al (2012a).
Imaging Mass Cytometry
(IMC) IMC was performed using the
Hyperion Imaging System
(
Standard BioTools
), a multiplexed spatial proteomics platform that enables simultaneous detection of
(13)
Cellular interaction of mycosis fungoides tumor cells changes from cytotoxic CD8+ T cells in plaques to B cells in tumors
Front Immunol
July 2, 2026
Veerle A. Merkus, Marieke E. IJsselsteijn, Marie S. N. Chevalier, Sanne de Haan, Vincent van Unen, Cornelis P. Tensen, Abdoel El Ghalbzouri, Anne M. R. Schrader, Ferenc A. Scheeren, Noel F. C. C. de Miranda,
et al.
demonstrated strong
IHC
performance were subsequently conjugated to a heavy metal and evaluated using the
Hyperion Imaging System
(
Standard BioTools
, San Francisco, CA, USA). The antibodies were conjugated in-house with heavy metal
(14)
Multimodal characterisation of spontaneous Merkel cell carcinoma in the endangered Caucasian squirrel (Sciurus anomalus pallescens): integrating spatial transcriptomics, imaging mass cytometry and metagenomic sequencing
J Vet Res
June 30, 2026
Peyman Mohammadzadeh, Amin Pilvaieh, Arshia Dousti, Mohammad Reza Salim Bahrami, Farshad Ziaee
enrichment – were performed in Seurat v. 4.3 (14).
Imaging mass cytometry
This was performed on a Fluidigm
Hyperion Imaging System
(
Standard BioTools
, San Francisco, CA, USA).
Formalin-fixed, paraffin-embedded
tissue sections 4 μm
(15)
Spatial immune atlas of breast cancer brain metastasis reveals CD163+ macrophage reprogramming associated with immune escape
J Immunother Cancer
June 24, 2026
Jiale Zhu, Junjie Ye, Yulin Ma, Zhirong Lin, Yupeng Wen, Jianpeng Sheng, Mei Yang
4°C with the antibody cocktail, slides were counterstained with iridium intercalator and imaged on a
Hyperion Imaging System
(
Standard BioTools
) at 1 µm resolution with identical acquisition parameters for all specimens.42 Image
(16)
Density-Adjusted Analysis of Cell Interactions to Decipher Tissue Landscape Changes
iScience
June 19, 2026
Misha Siddiqui, Azam Hamidinekoo, Jennifer Y. Tan, Renata Leke, Bader Zarrouki, Nick Trahearn, Yeman Brhane Hagos, Chirine Sakr, Andrea Lampis, Christopher Bagnall,
et al.
were then fixed and stained with the panel of antibodies shown in key resources table for IMC with the
Hyperion
system (
Standard Biotools
, San Francisco, CA, USA) according to the manufacturer’s guidelines. Images
(17)
Mechanisms of increased Alzheimer's disease pathology with R47H and R62H TREM2 variants
Acta Neuropathol
June 15, 2026
Nurun N. Fancy, Nanet Willumsen, Vicky M. N. Chau, Samuel L. Boulger, Harry J. Whitwell, Wenhao Wang, Baptiste Avot, Michael Thomas, Jonathan Talbot-Martin, Stergios Tsartsalis,
et al.
conjugation was performed using the Maxpar X8 protocol (
Standard BioTools
). IMC was performed using a
Hyperion
Imaging Systems First Generation (Standard BioTools) coupled to a
CyTOF
First Generation mass cytometer
(18)
Spatiotemporal organisation of residual disease in mouse and human BRCA1-deficient mammary tumours and breast cancer
Nature Communications
June 11, 2026
Demeter Túrós, Morgane Decollogny, Anna Moyseos, Astrid Chanfon, Myriam Siffert, Joanne Bousmar, Lou Romanens, Jean-Christophe Tille, Olivier Tredan, Intidhar Labidi-Galy,
et al.
quickly rinsed in distilled water and air-dried prior to acquisition. IMC data were acquired using the
Hyperion
™ Tissue Imager (
Standard BioTools
). Tissue was ablated using a 1 μm-diameter UV laser operating at 200
(19)
Modeling immune responses to autologous and allogeneic human stem cell–derived islet grafts in vivo
JCI Insight
June 8, 2026
Camillo Bechi Genzano, Giorgia Zanetti, Qian Du, Daniel Traum, Deeksha Lahori, Grant M. Downes, Sakshi A. Bhatele, Xiaolan Ding, Kyle D. Apley, Rebuma Firdessa Fite,
et al.
twice in ultrapure 18.2 MΩ water, before being air dried and acquired on the IMC (
Standard BioTools
,
Hyperion Imaging System
) according to Standard BioTools’ standard operating
procedures
, with a 200 Hz laser frequency and a
(20)
Mapping Immunity With Cutting‐Edge Spatial Biology and Tissue Cytometry Innovations
MedComm (2020)
June 1, 2026
Lilibeth Cárdenas‐Piedra, Selwin G. Samuel, Felicitas Mungenast, Dinesh Yasothkumar, Rupert C. Ecker, Jyotsna Batra
auto‐configuration after dye selection Up to 9‐plex in a single round,Manual sample preprocessing and
staining
,[44]
Hyperion
XTi imaging System/
Standard Biotools
,RNA: FISH/ RNAscope (RNAscope HiPlex V2) Protein: mass‐tagged
Page
<<
<
1
2
3
4
5
>
>>
Reviews
Be the First to Write a Review!
Hyperion+™ Imaging System from Standard BioTools Inc.
Get Pricing
Get Quote for this Product
Product Specs
Company Info
Citations
Reviews
Back To Top