BioLegend
Pacific Blue™ Anti-Human CD19
982404
HIB19
Info: Supplier Page View Product Specs
Browse Similar Products: Anti-CD19 Antibody Products
Staining for human CD19 is strong and specific. Easy to separate B cells by flow cytometry. Not much background.
Flow cytometry
Human tonsil
1:200 for 15 min at 4°C
Fc block
N/A
Fortessa LSRII
Single cell suspension from human tonsils stained with this antibody show specific staining of B cells. The population is clearly separated from remaining cells making B cell analysis easy.
Great staining for B cells.
For analyzing human B cells, this antibody works very well. It is not particularly bright so may require a slightly higher concentration.